Degrees of Reality Airway Anatomy of High-fidelity Human Patient Simulators and Airway Trainers

被引:106
|
作者
Schebesta, Karl [1 ]
Huepfl, Michael [1 ]
Roessler, Bernhard [1 ]
Ringl, Helmut [2 ]
Mueller, Michael P. [3 ]
Kimberger, Oliver [4 ]
机构
[1] Med Univ Vienna, Med Simulat & Emergency Management Res Grp, Dept Anesthesia Gen Intens Care & Pain Management, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[3] Univ Hosp Dresden, Interdisciplinary Med Simulat Ctr Dresden, Dept Anesthesiol, Dresden, Germany
[4] Med Univ Vienna, Div Gen Anesthesia & Intens Care, Dept Anesthesia Gen Intens Care & Pain Management, A-1090 Vienna, Austria
关键词
3-DIMENSIONAL COMPUTED-TOMOGRAPHY; TRAINING MANNEQUINS; DIFFICULT INTUBATION; EQUIPMENT MAN; MANAGEMENT; PERFORMANCE; MACINTOSH; EDUCATION; INSERTION; HISTORY;
D O I
10.1097/ALN.0b013e318254cf41
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper airway anatomy of four high-fidelity patient simulators and two airway trainers in comparison with actual patients by means of radiographic measurements. The volume of the pharyngeal airspace was the primary outcome parameter. Methods: Computed tomography scans of 20 adult trauma patients without head or neck injuries were compared with computed tomography scans of four high-fidelity patient simulators and two airway trainers. By using 14 predefined distances, two cross-sectional areas and three volume parameters of the upper airway, the manikins' similarity to a human patient was assessed. Results: The pharyngeal airspace of all manikins differed significantly from the patients' pharyngeal airspace. The HPS Human Patient Simulator (METI (R), Sarasota, FL) was the most realistic high-fidelity patient simulator (6/19 [32%] of all parameters were within the 95% CI of human airway measurements). Conclusion: The airway anatomy of four high-fidelity patient simulators and two airway trainers does not reflect the upper airway anatomy of actual patients. This finding may impact airway training and confound comparative airway device studies.
引用
收藏
页码:1204 / 1209
页数:6
相关论文
共 50 条
  • [1] Validity and fidelity of the upper airway in two high-fidelity patient simulators
    Schebesta, K.
    Spreitzgrabner, G.
    Hoerner, E.
    Huepfl, M.
    Kimberger, O.
    Roessler, B.
    MINERVA ANESTESIOLOGICA, 2015, 81 (01) : 12 - 18
  • [2] Airway Anatomy of AirSim High-fidelity Simulator
    Jelacic, Srdjan
    Ghioni, Victor
    Bowdle, Andrew
    ANESTHESIOLOGY, 2013, 118 (01) : 228 - 229
  • [3] A comparison of paediatric airway anatomy with the SimBaby high-fidelity patient simulator
    Schebesta, Karl
    Huepfl, Michael
    Ringl, Helmut
    Machata, Anette-Marie
    Chiari, Astrid
    Kimberger, Oliver
    RESUSCITATION, 2011, 82 (04) : 468 - 472
  • [4] Airway Anatomy of AirSim High-fidelity Simulator Reply
    Schebesta, Karl
    Kimberger, Oliver
    ANESTHESIOLOGY, 2013, 118 (01) : 229 - 230
  • [5] Using high-fidelity human patient simulators to teach physiology
    Harris, Judy R.
    Helyer, Richard J.
    Lloyd, Eugene
    MEDICAL EDUCATION, 2011, 45 (11) : 1159 - 1160
  • [6] Light at the end of the tunnel for high-fidelity airway training
    Shimmin, H.
    Muniz, C.
    Willers, J.
    Jones, E.
    ANAESTHESIA, 2018, 73 : 15 - 15
  • [7] High-fidelity Human Patient Simulators Compared with Human Actors in an Unannounced Mass-Casualty Exercise
    Schulz, Christian M.
    Skrzypczak, Matthias
    Raith, Stefan
    Hinzmann, Dominik
    Krautheim, Veronika
    Heuser, Fabian
    Mayer, Valentin
    Kreuzer, Christoph
    Himsl, Meike
    Holl, Michael
    Lipp, Christina
    Kochs, Eberhard F.
    Wagner, Klaus J.
    PREHOSPITAL AND DISASTER MEDICINE, 2014, 29 (02) : 176 - 182
  • [8] POTENTIAL USE AND LIMITATION OF HIGH-FIDELITY PATIENT SIMULATORS IN MEDICAL EDUCATION
    Almsherqi, Z.
    EDULEARN15: 7TH INTERNATIONAL CONFERENCE ON EDUCATION AND NEW LEARNING TECHNOLOGIES, 2015, : 8441 - 8441
  • [9] Static dimensional comparison of low-fidelity airway trainers to Human Morphometrics
    Kempski, Kelley M.
    Blackburn, August N.
    De Lorenzo, Robert A.
    Blackburn, Megan B.
    JOURNAL OF TRANSLATIONAL MEDICINE, 2017, 15
  • [10] EVALUATION OF MEDICAL HIGH-FIDELITY PATIENT SIMULATORS IN UNDERGRADUATE MEDICAL CURRICULUM
    Almsherqi, Z.
    EDULEARN12: 4TH INTERNATIONAL CONFERENCE ON EDUCATION AND NEW LEARNING TECHNOLOGIES, 2012, : 2878 - 2878