Better time-intensity trade revealed by bilateral giant magnetostrictive bone conduction

被引:2
|
作者
Kuroki, S [1 ]
Kaga, K [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Sensory & Motor Neurosci, Bunkyo Ku, Tokyo 1130033, Japan
关键词
auditory cognition; bone conduction; giant magnetostriction; interaural intensity difference; interaural time difference; normal hearing; sound lateralization; time-intensity trade;
D O I
10.1097/01.wnr.0000195663.76971.8b
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Sound lateralization tests were performed to compare the magnet coil bone-conduction headphone with the giant magnetostrictive bone-conduction headphone using 18 healthy participants. Although, no significant difference between these bone-conduction headphones was obtained for the interaural time difference and interaural intensity difference, a significant difference was obtained for the time-intensity trade. This revealed that the difference between the headphones is apparent in the integration of the heterogeneous sensations of the time and intensity difference at the cognitive level, but no difference is apparent between the homogeneous sensations of the discrimination of interaural time difference or interaural intensity difference at the sensory level. It was concluded that the difference at the cognitive level indicates the better performance of the giant magnetostrictive headphone.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 14 条
  • [1] TIME-INTENSITY TRADE AND LATERALIZED LOCATION
    ASP, CW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1967, 42 (05): : 1179 - &
  • [2] TIME-INTENSITY TRADE IN MEASUREMENTS OF AUDITORY FUNCTION
    HOPKINSO.NT
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (01): : 131 - &
  • [3] ELECTROPHYSIOLOGICAL ANALOG OF INTERAURAL TIME-INTENSITY TRADE
    WORDEN, FG
    MARSH, JT
    BREMNER, FJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1966, 39 (06): : 1086 - &
  • [4] Bone-conduction Eyeglasses Using a Giant Magnetostrictive Actuator
    Imoto, Kazuya
    Fujii, Hajime
    Mori, Mikio
    2017 IEEE 6TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE), 2017,
  • [5] Time-intensity trading in bilateral congenital aural atresia patients
    Schmerber, S
    Sheykholeslami, K
    Kermany, MH
    Hotta, S
    Kaga, K
    HEARING RESEARCH, 2005, 202 (1-2) : 248 - 257
  • [6] TIME-INTENSITY TRADE FOR SPEECH - A TEMPORAL SPEECH-STENGER EFFECT
    RAFFIN, MJM
    LILLY, DJ
    THORNTON, AR
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1976, 19 (04): : 749 - 766
  • [7] Design and nonlinear stability analysis of a micro giant magnetostrictive bone conduction vibrator
    Fu, Xin
    Yan, Hongbo
    Ai, Chaohui
    Wang, Jianxin
    PHYSICA SCRIPTA, 2025, 100 (03)
  • [8] Development of an implanted bone-conduction hearing aid using giant magnetostrictive material
    Koike, Takuji
    Yamamoto, Kensei
    Aoki, Michihito
    Homma, Kyoji
    Hato, Naohito
    Kanzaki, Sho
    HEARING RESEARCH, 2010, 263 (1-2) : 240 - 240
  • [9] O-RADS MRI Classification of Indeterminate Adnexal Lesions: Time-Intensity Curve Analysis Is Better Than Visual Assessment
    Wengert, Georg J.
    Dabi, Yohann
    Kermarrec, Edith
    Jalaguier-Coudray, Aurelie
    Poncelet, Edouard
    Porcher, Raphael
    Thomassin-Naggara, Isabelle
    Rockall, Andrea G.
    RADIOLOGY, 2022, 303 (03) : 566 - 575
  • [10] Intracochlear Measurements of Interaural Time and Level Differences Conveyed by Bilateral Bone Conduction Systems
    Farrell, Nyssa F.
    Hartl, Renee M. Banakis
    Benichoux, Victor
    Brown, Andrew D.
    Cass, Stephen P.
    Tollin, Daniel J.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (10) : 1476 - 1483