Bond model for prestressed strands in fire exposed concrete

被引:0
|
作者
Fellinger, JHH [1 ]
Stark, JWB [1 ]
Walraven, JC [1 ]
机构
[1] Delft Univ Technol, Ctr Fire Res, TNO Bldg & Construct Res, NL-2600 AA Delft, Netherlands
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For fire exposed concrete structures, no design rules exist for the detailed calculation of the bond stress of reinforcement. The effect of thermal stresses on the bond stress and the confining action of the surrounding concrete is currently neglected. This paper presents an elastic-plastic bond-slip model for the simulation of the anchorage behaviour of prestressed strands in concrete structures at both ambient and fire conditions. The model allows for a detailed simulation of the slip and prestress development during fire. The bond model is applied to interface elements between prestressed strands and the concrete structure in a 2D FE model. In this model the temperature effects on material properties of concrete and steel have been considered, according to Eurocode 2. The yield contour depends on the confinement action of the encasing concrete. An arbitrary relation has been set between the slip and the steel stress at one side and an artificial radial expansion of the strand at the other side. The response of the confining concrete against radial expansion of the strand is calculated in a second 2D FE model of the concrete cross section. This cross sectional model accounts for the effect of splitting cracks and also for temperature effects. The model is checked against tests on precast prestressed hollow core slabs at ambient and fire conditions.
引用
收藏
页码:21 / 33
页数:13
相关论文
共 50 条
  • [1] Analysis of the bond behaviour between prestressed strands and concrete in fire
    Khalaf, Jamal
    Huang, Zhaohui
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 128 : 12 - 23
  • [2] Reliability analysis of prestressed concrete beams exposed to fire
    Eamon, Christopher D.
    Jensen, Elin
    ENGINEERING STRUCTURES, 2012, 43 : 69 - 77
  • [3] Determining bond strength of seven-wire strands in prestressed concrete
    Mohandoss, Prabha
    Pillai, Radhakrishna G.
    Gettu, Ravindra
    STRUCTURES, 2021, 33 : 2413 - 2423
  • [4] Performance of Prestressed Concrete Bridge Girders Exposed to Fire
    Zhang, Gang
    Kodur, Venkatesh K. R.
    Wang, Cuijuan
    He, Shuanhai
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 890 - 899
  • [5] Modelling of Bond-slip between Prestressed Strands and Concrete at Elevated Temperatures
    Khalaf, Jamal
    Huang, Zhaohui
    STRUCTURES IN FIRE, 2016, : 71 - 78
  • [7] Influence of cover on bond of strands prestressed by pretensioning
    do Carmo, RNF
    Lopes, SMR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2001, 28 (06) : 938 - 948
  • [8] FATIGUE OF PRESTRESSED CONCRETE BEAMS WITH INCLINED STRANDS
    MULLER, JF
    DUX, PF
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (04): : 1122 - 1139
  • [9] Fatigue of prestressed concrete beams with inclined strands
    Muller, John F.
    Dux, Peter F.
    Journal of structural engineering New York, N.Y., 1994, 120 (04): : 1122 - 1139
  • [10] Transfer length of strands in prestressed concrete piles
    Wan, BL
    Harries, KA
    Petrou, MF
    ACI STRUCTURAL JOURNAL, 2002, 99 (05) : 577 - 585