A self-correcting loop for joint estimation-calibration in adaptive radar

被引:1
|
作者
Ye, WC
BarNess, Y
Haimovich, AM
机构
关键词
D O I
10.1109/NRC.1997.588329
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
It is well known that pointing and random angle errors degrade the performance of adaptive radar quickly, A joint adaptive estimation-calibration (JEC) algorithm is proposed to provide on-line look direction corrections and array calibration. The new algorithm is presented in the context of a generalized sidelobe canceler (GSC). The proposed algorithm uses the array output to generate a control signal for steering vector corrections, which in turn yield higher signal-to-noise and interference ratio (SNIR) at the array output. Doppler technique is used to provide cleaner reference of target signal, which results in better correction of the steering vector. A simple case is investigated explain how the scheme works end steady state condition analysis is provided, For an 8-element antenna array, the new algorithm is demonstrated by simulations, which show that the output SNIR is improved by the correction of pointing and random angle errors.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 38 条
  • [1] SELF-CORRECTING ADAPTIVE TRACKING SYSTEM
    Lau, Richard
    Kim, Heechang
    Pang, Marcus
    Neidhardt, Arnie
    Cisneros, Arturo
    Kaul, Vikram
    [J]. 2008 IEEE MILITARY COMMUNICATIONS CONFERENCE: MILCOM 2008, VOLS 1-7, 2008, : 1807 - 1813
  • [2] Performance analysis of the self-correcting adaptive filter
    Kim, J
    Perry, ET
    [J]. PROCEEDINGS OF THE THIRTY-SEVENTH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 2005, : 316 - 319
  • [3] Application of Self-Correcting Tomographic Inversion to a borehole radar test survey
    Rucareanu, M
    Chouteau, M
    Bellefleur, G
    [J]. GPR 2000: PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON GROUND PENETRATING RADAR, 2000, 4084 : 647 - 652
  • [4] PARAMETER-ESTIMATION FOR THE SIMPLE SELF-CORRECTING POINT PROCESS
    INAGAKI, N
    HAYASHI, T
    [J]. ANNALS OF THE INSTITUTE OF STATISTICAL MATHEMATICS, 1990, 42 (01) : 89 - 98
  • [5] The Self-Correcting Control Strategy of a Single Flux Linkage Closed Loop for a Contactor
    Tang, Longfei
    Chen, Wei
    Xu, Zhihong
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (11) : 11521 - 11530
  • [6] The Self-Correcting Control Strategy of a Single Flux Linkage Closed Loop for a Contactor
    Tang, Longfei
    Chen, Wei
    Xu, Zhihong
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2021, : 11521 - 11530
  • [7] THE CONSTRUCTION OF NON-BINARY SELF-CORRECTING CODES AND THE ESTIMATION OF THEIR NUMBER OF SIGNALS
    OSTIANU, VM
    [J]. DOKLADY AKADEMII NAUK SSSR, 1960, 135 (06): : 1382 - 1384
  • [8] Automatic self-correcting calibration method for arterial blood sampling detectors used in PET imaging
    Hichwa, R.D.
    Aykac, M.
    Bilgen, D.
    Ponto, L.L.B.
    Watkins, G.L.
    Wollenweber, S.D.
    Madsen, M.T.
    [J]. IEEE Transactions on Nuclear Science, 1999, 46 (6 III): : 2124 - 2127
  • [9] Nonlinear adaptive model predictive control based on self-correcting neural network models
    Alexandridis, A
    Sarimveis, H
    [J]. AICHE JOURNAL, 2005, 51 (09) : 2495 - 2506
  • [10] Automatic self-correcting calibration method for arterial blood sampling detectors used in PET imaging
    Hichwa, RD
    Aykac, M
    Bilgen, D
    Ponto, LLB
    Watkins, GL
    Wollenweber, SD
    Madsen, MT
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2124 - 2127