Coronary hemodynamics before and after rotational atherectomy with adjunctive balloon angioplasty

被引:0
|
作者
Nunez, BD [1 ]
Keelan, ET [1 ]
Higano, ST [1 ]
Lerman, A [1 ]
Garratt, KN [1 ]
Holmes, DR [1 ]
机构
[1] MAYO CLIN & MAYO FDN, ADULT CARDIAC CATHETERIZAT LAB, ROCHESTER, MN 55905 USA
关键词
no-reflow; phenomenon; rotational atherectomy; coronary flow; verapamil; nitroglycerin;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The phenomenon of ''no-reflow'' has been described frequently after rotational atherectomy. The aim of this study was to determine the coronary hemodynamic changes by Doppler flow wire before and after rotational atherectomy and adjunctive balloon angioplasty in 10 patients. All patients had TIMI-III flow at baseline. After rotational atherectomy alone, two patients had TIMI-I, four patients had TIMI-II, and four patients had TIMI-III flow. In addition, the number of Cineframes to Opacification of a preselected distal landmark increased twofold (from 49 +/- 12 to 118 +/- 27 frames; P<0.05). Intracoronary nitroglycerin and verapamil was associated with return to baseline of both measurments. Following adjunctive balloon angioplasty, there was an increase in lumen diameter (1.29 +/- 0.1 vs. 2.6 +/- 0.1 mm; P<0.05), coronary flow (81 +/- 14 to 154 +/- 18 ml/min; P<0.05), maximal absolute velocity (23 +/- 4 to 52 +/- 4 cm/sec; P<0.05), and vascular resistance decreased (1.74 +/- 0.4 to 0.74 +/- 0.4 mm Hg/ml/min; P<0.05). However, no change in coronary flow reserve was noted (1.24 +/- 0.1 vs. 1.5 +/- 0.3). Immediately after rotational atherectomy alone, there is a reduction in angiographically determined coronary flow, suggesting either distal microvascular spasm or distal microvascular obstruction. Regardless of the mechanism, the transient reduction of coronary flow was rapidly reversed by coronary vasodilators. Despite the significant improvement of coronary hemodynamics noted immediately after combined rotational atherectomy and balloon angioplasty, coronary flow reserve remained abnormal. Similarly, no change in coronary flow reserve has been reported immediately after balloon angioplasty alone. The lack of improvement in flow reserve after both balloon angioplasty and rotational atherectomy suggests that the mechanisms of improved flow reserve may be device independent, and remain unexplained. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:40 / 49
页数:10
相关论文
共 50 条
  • [1] INFLUENCE OF ADJUNCTIVE BALLOON ANGIOPLASTY ON CORONARY BLOOD-FLOW AFTER ROTATIONAL ATHERECTOMY
    KHOURY, AF
    BACH, RG
    KERN, MJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (03): : 272 - 276
  • [2] ROTATIONAL CORONARY ATHERECTOMY WITH ADJUNCTIVE BALLOON ANGIOPLASTY FOR THE TREATMENT OF OSTIAL LESIONS
    ZIMARINO, M
    CORCOS, T
    FAVEREAU, X
    COMMEAU, P
    TAMBURINO, C
    SPAULDING, C
    GUERIN, Y
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (01): : 22 - 27
  • [3] ROTATIONAL CORONARY ATHERECTOMY WITH ADJUNCTIVE BALLOON ANGIOPLASTY - WHICH IS THE PRIMARY AND WHICH IS THE ADJUNCTIVE TECHNIQUE
    ZIMARINO, M
    CORCOS, T
    FAVEREAU, X
    ELBAZ, N
    BROSSAIS, S
    TAMBURINO, C
    TOUSSAINT, M
    GUERIN, Y
    EIFERMAN, C
    BARTHELEMY, M
    SOUFFRANT, G
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A285 - A285
  • [4] ROTATIONAL CORONARY ATHERECTOMY AFTER UNSUCCESSFUL CORONARY BALLOON ANGIOPLASTY
    BROGAN, WC
    POPMA, JJ
    PICHARD, AD
    SATLER, LF
    KENT, KM
    MINTZ, GS
    LEON, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (10): : 794 - 798
  • [5] Effect of adjunctive balloon angioplasty after intravascular ultrasound-guided optimal directional coronary atherectomy - The result of Adjunctive Balloon Angioplasty after Coronary Atherectomy Study (ABACAS)
    Suzuki, T
    Hosokawa, H
    Katoh, O
    Fujita, T
    Ueno, K
    Takase, S
    Fujii, K
    Tamai, H
    Aizawa, T
    Yamaguchi, T
    Kurogane, H
    Kijima, M
    Oda, H
    Tsuchikane, E
    Hinohara, T
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) : 1028 - 1035
  • [6] Rotational coronary atherectomy with adjunctive balloon angioplasty: Evaluation of lumen enlargement by quantitative angiographic analysis
    Zimarino, M
    Corcos, T
    Favereau, X
    Elbaz, N
    Toussaint, M
    Garcia, E
    Tamburino, C
    Guerin, Y
    Barthelemy, M
    AMERICAN HEART JOURNAL, 1997, 133 (02) : 203 - 209
  • [7] Coronary Stenting After Rotational Atherectomy in Diffuse Lesions of the Small Coronary Artery: Comparison with Balloon Angioplasty Before Stenting
    Kwon, K
    Choi, D
    Choi, SH
    Koo, BK
    Jang, Y
    Shim, WH
    Cho, SY
    ANGIOLOGY, 2003, 54 (04) : 423 - 431
  • [8] Rotational Atherectomy in the Management of Ruptured and Entrapped Coronary Angioplasty Balloon
    Balasubramaniam, Karthik
    Elbarouni, Basem
    Kass, Malek
    Minhas, Kunal
    Ravandi, Amir
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 28 : S140 - S143
  • [9] Alternatives to balloon angioplasty - Radiofrequency angioplasty, directional coronary atherectomy, high-frequency rotational angioplasty and coronary extraction atherectomy
    Hombach, V
    Kochs, M
    Hoher, M
    Osterhues, HH
    Weismuller, P
    INTERNIST, 1997, 38 (01): : 11 - 19
  • [10] Effect of rotablator atherectomy and adjunctive balloon angioplasty on coronary blood flow
    Bowers, TR
    Stewart, RE
    ONeill, WW
    Reddy, VM
    Safian, RD
    CIRCULATION, 1997, 95 (05) : 1157 - 1164