How accurately and consistently do laboratories measure workplace concentrations of respirable crystalline silica?

被引:0
|
作者
Cox, Louis Anthony , Jr. [1 ]
机构
[1] Cox Associates, 503 Franklin St, Denver, CO 80218 USA
关键词
Respirable crystalline silica (RCS); Accuracy; Reliability; Laboratory error; Estimation error; Performance statistics; PERFORMANCE;
D O I
10.1016/j.yrtph.2016.09.008
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Permissible exposure limits (PELs) for respirable crystalline silica (RCS) have recently been reduced from 0.10 to 0.05 mg/m(3). This raises an important question: do current laboratory practices and standards for assessing RCS concentrations permit reliable discrimination between workplaces that are in compliance and workplaces that are not? To find out, this paper examines recent laboratory performance in quantifying RCS amounts on filters sent to them to assess their proficiency. A key finding is that accredited laboratories do not reliably (e.g., with 95% confidence) estimate RCS quantities to within a factor of 2. Thus, laboratory findings indicating that RCS levels are above or below a PEL provide little confidence that this is true. The current accreditation standard only requires laboratories to achieve estimates within three standard deviations of the correct (reference) value at least two thirds of the time, rather than a more usual standard such as within 25% of the correct value at least 95% of the time. Laboratory practices may improve as the new PEL is implemented, but they are presently essentially powerless to discriminate among RCS levels over most of the range of values that have been tested, leaving employers and regulators without a reliable means to ascertain when workplace RCS levels are above or below the PEL. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:268 / 274
页数:7
相关论文
共 17 条
  • [1] Evaluation of workplace exposure to respirable crystalline silica in Italy
    Scarselli, Alberto
    Corfiati, Marisa
    Di Marzio, Davide
    Iavicoli, Sergio
    [J]. INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2014, 20 (04) : 301 - 307
  • [2] COMMERCIAL LABORATORIES DO NOT MEASURE SERUM GASTRIN ACCURATELY OR PRECISELY
    NOTARFRANCESCO, V
    SAMUEL, S
    KANAKAMEDALA, S
    STRAUS, E
    [J]. GASTROENTEROLOGY, 1993, 104 (04) : A160 - A160
  • [3] Evaluation of workplace exposure to respirable crystalline silica in road construction industries in Alberta
    Couture, Ariel
    Elizabeth, Rose Marie Charuvil
    Lefsrud, Lianne
    Sattari, Fereshteh
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 2023, 39 (07) : 374 - 387
  • [4] How do we accurately measure foot motion?
    Davis, IS
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2004, 34 (09): : 502 - 503
  • [5] How Accurately Can a Single Receptor Measure Ligand Concentrations?
    Sun, Sean X.
    [J]. BIOPHYSICAL JOURNAL, 2014, 106 (04) : 778 - 779
  • [6] Crystalline Silica in Quartz Agglomerates: A Study of Bulk Materials and an Evaluation of the Respirable Levels in Workplace Atmospheres
    Fernandez Rodriguez, P.
    Diaz Huerta, V.
    Madera Garcia, J.
    Martinez-Blanco, D.
    Blanco, J. A.
    [J]. SILICA AND ASSOCIATED RESPIRABLE MINERAL PARTICLES, 2014, 1565 : 54 - 72
  • [7] Concentrations of respirable crystalline silica and radon among tanzanite mining communities in Mererani, Tanzania
    Mbuya, Alexander W.
    Mboya, Innocent B.
    Semvua, Hadija H.
    Msuya, Sia E.
    Howlett, Patrick J.
    Mamuya, Simon H.
    [J]. ANNALS OF WORK EXPOSURES AND HEALTH, 2024, 68 (01) : 48 - 57
  • [8] Respirable dust and crystalline silica concentrations among workers at a brick kiln in Bhaktapur, Nepal
    Beard, John D.
    Collingwood, Scott C.
    Lecheminant, James D.
    Peterson, Neil E.
    Reynolds, Paul R.
    Arroyo, Juan A.
    South, Andrew J.
    Farnsworth, Clifton B.
    Fong, Gerardo
    Cisneros, Taylor
    Taylor, Mariah
    Sanjel, Seshananda
    Johnston, James D.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2024, 21 (04) : 247 - 258
  • [9] How Consistently Do We Measure Bruises? A Comparison of Manual and Electronic Methods
    Lawson, Zoe
    Dunstan, Frank
    Nuttall, Diane
    Maguire, Sabine
    Kemp, Alison
    Young, Stephen
    Barker, Michael
    David, Laura
    [J]. CHILD ABUSE REVIEW, 2015, 24 (01) : 28 - 36
  • [10] Will the Occupational Safety and Health Administration's Proposed Standards for Occupational Exposure to Respirable Crystalline Silica Reduce Workplace Risk?
    Dudley, Susan E.
    Morriss, Andrew P.
    [J]. RISK ANALYSIS, 2015, 35 (07) : 1191 - 1196