In-situ temperature calibration procedure for temperature and strain fibre Bragg grating sensors for monitoring pre-stressing strands

被引:1
|
作者
Mckeeman, I. [1 ]
Fusiek, G. [1 ]
Perry, M. [1 ]
Niewczas, P. [1 ]
Johnston, M. [2 ]
机构
[1] Univ Strathclyde, Dept Engn, Glasgow, Lanark, Scotland
[2] Nucl Generat, EDF Energy, Civil Design Grp, E Kilbride, Lanark, Scotland
关键词
prestress monitoring; fibre Bragg gratings; structural health monitoring; temperature calibration; OPTIC SENSORS;
D O I
10.1117/12.2193193
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, we demonstrate active and passive methods for in-situ temperature calibration of fibre Bragg grating strain and temperature sensors. The method is suitable for characterizing sensors which are already attached to the steel reinforcements of civil structures. The proposed method, which involves the use of active induction heating or passive room temperature fluctuations, can be implemented using portable equipment, is time efficient, and can be used to calibrate attached sensors on-site, rather than in lab conditions. Preliminary results of the induction heating calibration show good agreement with pre-calibrated temperature sensors. In-situ calibration of fibre strain sensors, attached to a prestressing strand is also successfully carried out.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Identifying fabrication defects of metal packaged fibre Bragg grating sensors for smart pre-stressing strands
    Mckeeman, I.
    Niewczas, P.
    Johnston, M.
    [J]. 2015 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS), 2015, : 61 - 65
  • [2] Pre-strain effects on CYTOP fibre Bragg grating temperature sensors
    Pospori, A.
    Ioannou, A.
    Kalli, K.
    [J]. MICRO-STRUCTURED AND SPECIALTY OPTICAL FIBRES VII, 2022, 12140
  • [3] A strain-isolated fibre Bragg grating sensor for temperature compensation of fibre Bragg grating strain sensors
    Haran, FM
    Rew, JK
    Foote, PD
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (08) : 1163 - 1166
  • [4] Sampled fibre Bragg grating sensors for simultaneous strain and temperature measurement
    Frazao, O
    Romero, R
    Rego, G
    Marques, PVS
    Salgado, HM
    Santos, JL
    [J]. ELECTRONICS LETTERS, 2002, 38 (14) : 693 - 695
  • [5] In-situ optical fibre sensors for temperature and salinity monitoring
    Marrec, L
    Bourgerette, T
    Datin, E
    Ferchaud, N
    Pucel, B
    Quétel, L
    Renault, C
    Tregoat, D
    [J]. Oceans 2005 - Europe, Vols 1 and 2, 2005, : 1276 - 1278
  • [6] Fibre Bragg grating encapted with no-core fibre sensors for SRI and temperature monitoring
    Daud, S.
    Amiri, I. S.
    Noorden, A. F. A.
    Ali, J.
    Yupapin, P.
    [J]. RESULTS IN PHYSICS, 2018, 9 : 1685 - 1687
  • [7] In-Situ High Temperature and Large Strain Monitoring During a Copper Casting Process Based on Regenerated Fiber Bragg Grating Sensors
    Bian, Qiang
    Bauer, Constantin
    Stadler, Andrea
    Lindner, Markus
    Jakobi, Martin
    Volk, Wolfram
    Koch, Alexander W.
    Roths, Johannes
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (20) : 6660 - 6669
  • [8] Multipoint cure monitoring of temperature and strain of carbon fibre-reinforced plastic shafts using fibre Bragg grating sensors
    Ding, Guoping
    Cao, Hao
    Xie, Chen
    [J]. NONDESTRUCTIVE TESTING AND EVALUATION, 2019, 34 (02) : 117 - 134
  • [9] Simultaneous independent temperature and strain measurement using in-fibre Bragg grating sensors
    James, SW
    Dockney, ML
    Tatam, RP
    [J]. ELECTRONICS LETTERS, 1996, 32 (12) : 1133 - 1134
  • [10] DEMULTIPLEXING OF FIBER BRAGG GRATING TEMPERATURE AND STRAIN SENSORS
    BRADY, GP
    HOPE, S
    RIBEIRO, ABL
    WEBB, DJ
    REEKIE, L
    ARCHAMBAULT, JL
    JACKSON, DA
    [J]. OPTICS COMMUNICATIONS, 1994, 111 (1-2) : 51 - 54