Retrospectively ECG-gated multi-detector row CT of the chest: Does ECG-gating improve three-dimensional visualization of the bronchial tree?

被引:11
|
作者
Schertler, T [1 ]
Wildermuth, S [1 ]
Willmann, JK [1 ]
Crook, DW [1 ]
Marincek, B [1 ]
Boehm, T [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, Dept Med Radiol, CH-8091 Zurich, Switzerland
关键词
shaded surface display; virtual bronchoscopy; ECG-gated MDCT;
D O I
10.1055/s-2004-812777
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P < 0.05). The summary scores for visualization of bronchial segments for different diastolic reconstructions did not differ significantly. The effective radiation dose and the SNR were significantly higher with the ECG-gated acquisition technique (P < 0.05). Conclusion: The bronchial tree is significantly better visualized when using non-ECG-gated MDCT compared to ECG-gated MDCT. Additionally, non-ECGgated techniques require less radiation exposure. Thus, the current retrospective ECG-gating technique does not provide any additional benefit for 3D visualization of the bronchial tree and VB.
引用
收藏
页码:513 / 521
页数:9
相关论文
共 35 条
  • [1] Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Heuschmid, M
    Georg, C
    Ohnesorge, B
    Kuzo, R
    Claussen, CD
    [J]. RADIOLOGY, 2001, 221 (03) : 683 - 688
  • [2] Segmentation of ECG-gated multi-detector row CT cardiac images for functional analysis
    Kim, JS
    Na, Y
    Bae, KT
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1718 - 1726
  • [3] Image quality of volume rendering of the bronchial tree: Kymogram-gated versus retrospectively ECG-gated and non-gated multi-row detector CT
    Boehm, T
    Alkadhi, H
    Sennst, DA
    Schertler, T
    Kachelriess, M
    Kalender, W
    Marincek, B
    Wildermuth, S
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (02) : 173 - 181
  • [4] ECG-gated multi-detector row CT for assessment of mitral valve disease: initial experience
    Jürgen K. Willmann
    Richard Kobza
    Justus E. Roos
    Mario Lachat
    Rolf Jenni
    Paul R. Hilfiker
    Thomas F. Lüscher
    Borut Marincek
    Dominik Weishaupt
    [J]. European Radiology, 2002, 12 : 2662 - 2669
  • [5] ECG-gated multi-detector row CT for assessment of mitral valve disease:: initial experience
    Willmann, JK
    Kobza, R
    Roos, JE
    Lachat, M
    Jenni, R
    Hilfiker, PR
    Lüscher, TF
    Marincek, B
    Weishaupt, D
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2662 - 2669
  • [6] Coronary artery anomalies: Classification and ECG-gated multi-detector row CT findings with angiographic correlation
    Kim, So Yeon
    Seo, Joon Beom
    Do, Kyung-Hyun
    Heo, Jeong-Nam
    Lee, Jin Seong
    Song, Jae-Woo
    Choe, Yeon Hyeon
    Kim, Tae Hoon
    Yong, Hwan Seok
    Choi, Sang Il
    Song, Koun-Sik
    Lim, Tae-Hwan
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 317 - U2
  • [7] Coronary artery anomalies: Classification and ECG-gated multi-detector row CT findings with angiographic correlation - Invited commentary
    White, Charles S.
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 333 - 334
  • [8] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [9] Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT
    Yamada, K
    Soejima, T
    Minami, T
    Yoden, E
    Watanabe, Y
    Takenaka, D
    Imai, M
    Okayama, T
    Fujii, M
    Sugimura, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 235 - 239
  • [10] ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings
    Francone, M
    Carbone, I
    Danti, M
    Lanciotti, K
    Cavacece, M
    Mirabelli, F
    Gaudio, C
    Catalano, C
    Passariello, R
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (01) : 15 - 24