摘要
Monitoring a driver's health condition is essential for advanced driver assistance systems. To detect the driver's health condition, we propose a new system using a contactless biometric radar sensor to monitor the driver's heart rate. The radar sensor measures a microdisplacement of the driver's body surface, and heartbeat signals can be obtained. However, the observed signals are contaminated by noise signals such as body movement and car vibration. The proposed system utilizes blind source separation algorithms and extracts the driver's heartbeat signal from the noisy observation. Furthermore, the estimated heartbeat signal is input to a heart rate estimation algorithm. In experiments, we built a vibration measurement system to simulate a moving car, and an actual noisy heartbeat signal from a subject sitting on a driver's seat was measured. The results show that the proposed system can accurately estimate the subject's heart rate by removing the noise signals.
引用
收藏
页码:1156 / 1163
页数:8
相关论文
共 50 条
  • [1] A Blind Source Separation Framework for Monitoring Heart Beat Rate Using Nanofiber-Based Strain Sensors
    Zou, Liang
    Chen, Xun
    Servati, Amir
    Soltanian, Saeid
    Servati, Peyman
    Wang, Z. Jane
    [J]. IEEE SENSORS JOURNAL, 2016, 16 (03) : 762 - 772
  • [2] Blind Source Separation Using Virtual Sensors
    Khani, Mahdi Mahdi
    Kahaei, Mohammad Hossein
    [J]. ICDT: 2009 FOURTH INTERNATIONAL CONFERENCE ON DIGITAL TELECOMMUNICATIONS, 2009, : 107 - 110
  • [3] Denoising using Blind Source Separation for pyroelectric sensors
    Huez R.
    Nuzillard D.
    Billat A.
    [J]. EURASIP Journal on Advances in Signal Processing, 2001 (1) : 53 - 65
  • [4] Video-based human heart rate measurement using joint blind source separation
    Qi, Huan
    Guo, Zhenyu
    Chen, Xun
    Shen, Zhiqi
    Wang, Z. Jane
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 31 : 309 - 320
  • [5] Comparison of Blind Source Separation Algorithms for Optical Heart Rate Monitoring
    Christinaki, Eirini
    Giannakakis, Giorgos
    Chiarugi, Franco
    Pediaditis, Matthew
    Iatraki, Galateia
    Manousos, Dimitris
    Marias, Kostas
    Tsiknakis, Manolis
    [J]. 2014 EAI 4TH INTERNATIONAL CONFERENCE ON WIRELESS MOBILE COMMUNICATION AND HEALTHCARE (MOBIHEALTH), 2014, : 339 - 342
  • [6] A Novel Method for Deinterleaving of Radar Signals Using Blind Source Separation
    Lu Wei
    Ma Ming
    [J]. INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 1053 - 1057
  • [7] Resting heart rate estimation using PIR sensors
    Kapu, Hemanth
    Saraswat, Kavisha
    Ozturk, Yusuf
    Cetin, A. Enis
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2017, 85 : 56 - 61
  • [8] Robust estimation of shape and polarisation using blind source separation
    Zhang, Lichi
    Hancock, Edwin R.
    [J]. PATTERN RECOGNITION LETTERS, 2013, 34 (08) : 856 - 862
  • [9] Robust Shape and Polarisation Estimation Using Blind Source Separation
    Zhang, Lichi
    Hancock, Edwin R.
    [J]. COMPUTER ANALYSIS OF IMAGES AND PATTERNS: 14TH INTERNATIONAL CONFERENCE, CAIP 2011, PT I, 2011, 6854 : 178 - 185
  • [10] Multiple DOA Estimation and Blind Source Separation Using Estimation-Maximization
    Dorfan, Yuval
    Schwartz, Ofer
    Schwartz, Boaz
    Habets, Emanuel A. P.
    Gannot, Sharon
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON THE SCIENCE OF ELECTRICAL ENGINEERING (ICSEE), 2016,