The role of the patellar tendon angle and patellar flexion angle in the interpretation of sagittal plane kinematics of the knee after knee arthroplasty: A modelling analysis

被引:6
|
作者
van Duren, B. H. [1 ,2 ]
Pandit, H. [2 ]
Pechon, P. [3 ]
Hart, A. [1 ]
Murray, D. W. [4 ]
机构
[1] UCL, Inst Orthopaed & Musculoskeletal Sci, London, England
[2] Univ Leeds, Leeds Inst Rheumat & Musculodkeletal Med, Leeds, W Yorkshire, England
[3] Univ Coll Hosp, London, England
[4] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford, England
来源
KNEE | 2018年 / 25卷 / 02期
关键词
Knee; Modelling; Arthroplasty; Kinematics; TKR; TKA; Patellar tendon angle; Patellar flexion angle; MOBILE-BEARING; REPLACEMENT; JOINT; CONSTRAINTS; RESECTION; LENGTH;
D O I
10.1016/j.knee.2018.01.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Many different measures have been used to describe knee kinematics. This study investigated the changes of two measures, the patellar tendon angle and the patellar flexion angle, in response to variations in the geometry of the knee due to surgical technique or implant design.& para;& para;Methods: A mathematical model was developed to calculate the equilibrium position of the extensor mechanism for a particular tibiofemoral position. Calculating the position of the extensor mechanism allowed for the determination of the patellar tendon angle and patellar flexion angle relationships to the knee flexion angle. The model was used to investigate the effect of anterior-posterior position of the femur, change in joint line, patellar thickness (overstuffing, understuffing), and patellar tendon length; these parameters were varied to determine the effect on the patellar tendon angle/knee flexion angle and patellar flexion angle/knee flexion angle relationships.& para;& para;Results: The patellar tendon angle was a good indicator of anterior-posterior femoral position and change in patellar thickness, and the patellar flexion angle a good indicator of change in joint line, and patellar tendon length.& para;& para;Conclusions: The patellar tendon angle/knee flexion angle relationship was found to be an effective means of identifying abnormal kinematics post-knee arthroplasty. However, the use of both the patellar tendon angle and patellar flexion angle together provided a more informative overview of the sagittal plane kinematics of the knee. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:240 / 248
页数:9
相关论文
共 50 条
  • [1] Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty?
    R. Stagni
    S. Fantozzi
    F. Catani
    A. Leardini
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 949 - 954
  • [2] Can Patellar Tendon Angle reveal sagittal kinematics in total knee arthroplasty?
    Stagni, R.
    Fantozzi, S.
    Catani, F.
    Leardini, A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (07) : 949 - 954
  • [3] A Sagittal Patellar Angle Linear Equation Reflecting Patellofemoral Kinematics: Evaluation of Patellar Height at any Degree of Knee Flexion Angle
    Cui, Lu-kuan
    Kang, Kai
    Zheng, Xiao-zuo
    Jiang, Shi-gang
    Huang, Wen-tao
    Gao, Shi-jun
    [J]. ORTHOPAEDIC SURGERY, 2022, 14 (01) : 3 - 9
  • [4] Sagittal patellar flexion angle: a novel clinically validated patellar height measurement reflecting patellofemoral kinematics useful throughout knee flexion
    Michael J. Dan
    James McMahon
    William C. H. Parr
    Nancy Briggs
    Samuel MacDessi
    Bruce Caldwell
    William R. Walsh
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 975 - 983
  • [5] Sagittal patellar flexion angle: a novel clinically validated patellar height measurement reflecting patellofemoral kinematics useful throughout knee flexion
    Dan, Michael J.
    McMahon, James
    Parr, William C. H.
    Briggs, Nancy
    MacDessi, Samuel
    Caldwell, Bruce
    Walsh, William R.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (03) : 975 - 983
  • [6] Physiological sagittal plane patellar kinematics during dynamic deep knee flexion
    Hamai, Satoshi
    Dunbar, Nicholas J.
    Moro-oka, Taka-aki
    Miura, Hiromasa
    Iwamoto, Yukihide
    Banks, Scott A.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (08) : 1477 - 1482
  • [7] Physiological sagittal plane patellar kinematics during dynamic deep knee flexion
    Satoshi Hamai
    Nicholas J. Dunbar
    Taka-aki Moro-oka
    Hiromasa Miura
    Yukihide Iwamoto
    Scott A. Banks
    [J]. International Orthopaedics, 2013, 37 : 1477 - 1482
  • [8] Intraoperative patellar tendon strain: predicting the range of knee flexion after total knee arthroplasty
    Gejo, Ryuichi
    Morita, Yuji
    Matsushita, Isao
    Sugimori, Kazuhito
    Watanabe, Hiroki
    Kimura, Tomoatsu
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2009, 14 (01) : 51 - 55
  • [9] The effect of patellar thickness on intraoperative knee flexion and patellar tracking in total knee arthroplasty
    Bengs, Benjamin C.
    Scott, Richard D.
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (05): : 650 - 655
  • [10] Analyzing the Role of Patellar Tendon Force During Flexion of the Knee
    Imran, Ahmed
    [J]. WORLD CONGRESS ON ENGINEERING - WCE 2013, VOL III, 2013, : 1929 - 1932