THE BIORESORBABLE VASCULAR SCAFFOLD EXHIBITS LOW RATES OF STRUT MALAPPOSITION AS ASSESSED BY OPTICAL COHERENCE TOMOGRAPHY

被引:0
|
作者
Brown, Adam J. [1 ]
Hoole, Stephen P. [1 ]
McCormick, Liam M. [1 ]
Braganza, Denise M. [1 ]
West, Nick E. J. [1 ]
机构
[1] Papworth Hosp NHS Trust, Cambridge, England
关键词
D O I
10.1016/S0735-1097(13)61654-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:E1654 / E1654
页数:1
相关论文
共 50 条
  • [1] Bioresorbable vascular scaffold strut disruption after crossing with an optical coherence tomography imaging catheter
    Sato, Kastsumasa
    Panoulas, Vasileios F.
    Naganuma, Toru
    Miyazaki, Tadashi
    Latib, Azeem
    Colombo, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (03) : E116 - E119
  • [2] Serial Optical Coherence Tomography Assessment of the Everolimus-Eluting Absorb™ Bioresorbable Vascular Scaffold: Strut Coverage and Dynamic Malapposition Patterns at 9-month
    Antonsen, Lisbeth
    Thayssen, Per
    Jensen, Lisette Okkels
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B151 - B151
  • [3] Bioresorbable Vascular Scaffold Thrombosis: Clinical and Optical Coherence Tomography Findings
    Cuesta, Javier
    Garcia-Guimaraes, Marcos
    Basante, Teresa
    Rivero, Fernando
    Antuna, Paula
    Alfonso, Fernando
    REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (01): : 90 - 91
  • [5] Optical coherence tomography guidance during bioresorbable vascular scaffold implantation
    Secco, Gioel Gabrio
    Verdoia, Monica
    Pistis, Gianfranco
    De Luca, Giuseppe
    Vercellino, Matteo
    Audo, Andrea
    Parisi, Rosario
    Reale, Maurizio
    Ballestrero, Giorgio
    Marino, Paolo Nicola
    Di Mario, Carlo
    JOURNAL OF THORACIC DISEASE, 2017, 9 : S986 - S993
  • [6] Optical Coherence Tomography Image of Coronary Spasm in a Bioresorbable Vascular Scaffold
    Roa-Garrido, Jessica
    Gomez-Menchero, Antonio E.
    El Amrawy, Ahmed Mahmoud
    Cardenal-Piris, Rosa
    Camacho-Freire, Santiago
    Francisco Diaz-Fernandez, Jose
    CANADIAN JOURNAL OF CARDIOLOGY, 2018, 34 (03) : 343.e9 - 343.e10
  • [7] Increased circumferental vessel wall calcification predisposes to stent strut malapposition as assessed by optical coherence tomography
    Paulo, M.
    Lindsay, A. C.
    Alegria-Barrero, E.
    Chan, P. H.
    Foin, N.
    Di Mario, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1006 - 1006
  • [8] Persistent Bioresorbable Vascular Scaffold by Optical Coherence Tomography Imaging at 5 Years
    Moriyama, Noriaki
    Shishido, Koki
    Tobita, Kazuki
    Takada, Takuma
    Ochiai, Tomoki
    Tsukuda, Saori
    Yamanaka, Futoshi
    Sugitatsu, Kazuya
    Mizuno, Shingo
    Tanaka, Yutaka
    Murakami, Masato
    Matsumi, Junya
    Takahashi, Saeko
    Akasaka, Takeshi
    Saito, Shigeru
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (02) : E11 - E13
  • [9] In vivo characterisation of bioresorbable vascular scaffold strut interfaces using optical coherence tomography with Gaussian line spread function analysis
    Sheehy, Alexander
    Gutierrez-Chico, Juan Luis
    Diletti, Roberto
    Oberhauser, James P.
    Glauser, Thierry
    Harrington, Joel
    Kossuth, Mary Beth
    Rapoza, Richard J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    EUROINTERVENTION, 2012, 7 (10) : 1227 - 1235
  • [10] In Vivo Characterization of Bioresorbable Vascular Scaffold Strut Interfaces Using Optical Coherence Tomography with Gaussian Line Spread Function Analysis
    Sheehy, Alexander
    Gutierrez-Chico, Juan Luis
    Dilettr, Roberto
    Oberhauser, James P.
    Clauser, Thierry
    Harrington, Joel
    Kossuth, Mary Beth
    Rapoza, Richard J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B171 - B171