Endobronchial ultrasound and positron emission tomography positive mediastinal lymph nodes

被引:53
|
作者
Plat, G
Pierard, P
Haller, A
Hutsebaut, J
Faber, J
Dusart, M
Eisendrath, P
Sculier, JP
Ninane, V
机构
[1] St Pierre Hosp, Chest Serv, B-1000 Brussels, Belgium
[2] Inst Jules Bordet, Dept Internal Med, B-1000 Brussels, Belgium
[3] Inst Jules Bordet, Dept Nucl Med, B-1000 Brussels, Belgium
[4] St Pierre Hosp, Dept Pathol, Brussels, Belgium
关键词
endobronchial ultrasound; lung cancer; mediastinal lymphadenopathy; positron emission tomography scan; staging; transbronchial needle aspiration;
D O I
10.1183/09031936.06.00139204
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Positron emission tomography with 18F-fluoro-2-deOXY-D-glucose (FDG-PET) is more accurate than computed tomography for staging of mediastinal (hilar) lymph nodes. In the case of positive findings, tissue sampling of lymph nodes is required. The diagnostic/staging yield of transbronchial needle aspiration (TBNA) following endobronchial ultrasound (EBUS) localisation was assessed in this particular clinical setting. The number of avoided surgical procedures was evaluated. All consecutive patients referred for staging and/or diagnosis of mediastinal FDG-PET positive lesions were included. Data were prospectively collected. TBNA sampling of lymph nodes was performed after EBUS localisation. If no diagnosis was reached, further surgical sampling or adequate follow-up was performed. From January 2003 to June 2004, 33 patients were included. The average number of TBNA samples per patient was 4.2 +/- 1.5. Cytological or histological diagnoses were obtained in 27 (82%) of the patients, of which 78% were obtained after previous EBUS localisation. In 25 (76%) of the 33 patients, surgical staging procedures were suppressed. In conclusion, transbronchial needle aspiration after endobronchial ultrasound localisation should be considered as a primary method of evaluation of lymph nodes positive by positron emission tomography with 18F-fluoro-2-deoxy-D-glucose, and may replace the majority of surgical mediastinal staging/diagnostic procedures.
引用
收藏
页码:276 / 281
页数:6
相关论文
共 50 条
  • [1] Endobronchial ultrasound and PET positive mediastinal lymph nodes
    Faber, J
    Pierard, P
    Prigogine, T
    Dusart, M
    Haller, A
    Bosschaerts, T
    Sculier, JP
    Ninane, V
    REVUE DES MALADIES RESPIRATOIRES, 2006, 23 (01) : 37 - 42
  • [2] Endobronchial and endoscopic ultrasound for assessment of PET positive mediastinal lymph nodes
    Rintoul, R. C.
    Buttery, R. C.
    Hardy, C.
    Rassl, D.
    Carroll, N.
    LUNG CANCER, 2007, 57 : S2 - S2
  • [3] MISCLASSIFICATION OF MEDIASTINAL LYMPH NODES BY ENDOBRONCHIAL ULTRASOUND (EBUS)
    Leem, Cho S.
    Yoon, Ho-Il
    Lee, Choon-Taek
    Jheon, Sanghoon
    Lee, Jae Ho
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S952 - S952
  • [4] Endobronchial ultrasound-guided transbronchial needle aspiration of hilar and mediastinal lymph nodes detected on 18F-fluorodeoxyglucose positron emission tomography/computed tomography
    Minami, Daisuke
    Takigawa, Nagio
    Oda, Naohiro
    Ninomiya, Takashi
    Kubo, Toshio
    Ohashi, Kadoaki
    Sato, Akiko
    Hotta, Katsuyuki
    Tabata, Masahiro
    Kaji, Mitsumasa
    Tanimoto, Mitsune
    Kiura, Katsuyuki
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2016, 46 (06) : 529 - 533
  • [5] Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration Of Hilar And Mediastinal Lymph Nodes Detected On 18f-Fluorodeoxyglucose Positron Emission Tomography/computed Tomography
    Minami, D.
    Takigawa, N.
    Kato, Y.
    Ninomiya, T.
    Kubo, T.
    Ohashi, K.
    Hotta, K.
    Shibayama, T.
    Miyahara, N.
    Tabata, M.
    Kanehiro, A.
    Tanimoto, M.
    Kiura, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [6] A comparision of endobronchial ultrasound-guided transbronchial needle aspiration and integrated positron emission tomography-computed tomography in the diagnosis of malignant mediastinal/hilar lymph nodes
    Comert, Sevda Sener
    Caglayan, Benan
    Fidan, Ali
    Salepci, Banu
    Dogan, Coskun
    Demirhan, Recep
    Ece, Dilek
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 20 (04): : 843 - 849
  • [7] Cytologic Evaluation of Positron Emission Tomography-Computed Tomography-Positive Lymph Nodes Sampled by Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
    Gan, Qiong
    Stewart, John M.
    Valik, Erik
    Eapen, George
    Caraway, Nancy P.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2019, 143 (10) : 1265 - 1270
  • [8] Ultrasonographic evaluation of mediastinal lymph nodes using endobronchial ultrasound
    Shafiek, Hanaa
    Fiorentino, Federico
    Peralta, Alejandro
    Sauleda, Jaume
    Cosio, Borja G.
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [9] The role of endobronchial ultrasound elastography in the diagnosis of mediastinal lymph nodes
    Adel S. Bediwy
    Mohamed S. Hantira
    Dalia El Sharawy
    Ayman El Saqa
    Egyptian Journal of Bronchology, 2017, 11 (3) : 238 - 243
  • [10] Endobronchial Ultrasound Elastography for Diagnosing Mediastinal and Hilar Lymph Nodes
    He Hai-Yan
    Huang Mao
    Zhu Jie
    Ma Hang
    Lyu Xue-Dong
    中华医学杂志(英文版), 2015, 128 (20) : 2720 - 2725