Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading

被引:46
|
作者
Ccahuana Vasqueza, Vanessa Zulema [2 ]
Ozcan, Mutlu [1 ]
Kimpara, Estevao Tomomitsu [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Dent & Dent Hyg, Acad Ctr Oral Hlth, NL-9713 AV Groningen, Netherlands
[2] Sao Paulo State Univ, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil
关键词
Ceramic; EDS; Gold alloy; Mechanical aging; Shear bond strength; Thermal aging; Titanium; LOW-FUSING PORCELAIN; BOND STRENGTH; FLEXURAL STRENGTH; FATIGUE-STRENGTH; DENTAL PORCELAIN; CAST TITANIUM; SHEAR TEST; METAL; MOLD; RESTORATIONS;
D O I
10.1016/j.dental.2008.07.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy. Methods. Metallic frameworks (diameter: 5 min, thickness: 4 mm) (N = 96, n = 12 per group) were cast in cpTi and gold alloy, airborne particle abraded with 150 mu m aluminum oxide. Low-fusing glassy matrix ceramics and a conventional feldspathic ceramic were fired onto the alloys (thickness: 4mm). Four experimental groups were formed; Gr1 (control group): Vita Omega 900-Au-Pd alloy; Gr2: Ticeram-cpTi; Gr3: Super Porcelain Ti-22-cpTi and G4: Vita Titankeramik-cpTi. While half of the specimens from each ceramic-metal combination were randomly tested without aging (water storage at 37 C for 24h only), the other half were first thermocycled (6000 cycles, between 5 and 55 C, dwell time: 13 s) and then mechanically loaded (20,000 cycles under SON load, immersion in distilled water at 37 C). The ceramic-alloy interfaces were loaded under shear in a universal test machine (cross-head speed: 0.5 mm/min) until failure occur-red. Failure types were noted and the interfaces of the representative fractured specimens from each group were examined with stereo microscope and scanning electron microscope (SEM). in an additional study (N = 16, n = 2 per group), energy dispersive X-ray spectroscopy (EDS) analysis was performed from ceramic-alloy interfaces. Data were analyzed using ANOVA and Tukey's test. Results. Both ceramic-metal combinations (p < 0.001) and aging conditions (p < 0,001) significantly affected the mean bond strength values. Thermal- and mechanical-cycling decreased the bond strength (MPa) results significantly for Gr3 (33.4 +/- 4.2) and Gr4 (32.1 +/- 4.8) when compared to the non-aged groups (42.9 +/- 8.9, 42.4 +/- 5.2, respectively). Gr1 was not affected significantly from aging conditions (61.3 +/- 8.4 for control, 60.7 +/- 13.7 after aging) (p > 0.05). Stereomicroscope images showed exclusively adhesive failure types at the opaque ceramic-cpTi interfacial zone with no presence of ceramic on the substrate surface but with a visible dark titanium oxide layer in Groups 2-4 except Gr1 where remnants of bonder ceramic was visible. EDS analysis from the interfacial zone for cpTi-ceramic groups showed predominantly 34.5-85.1% O-2 followed by 1.1-36.7% Aland 0-36.3% Si except for Super Porcelain Ti-22 where a small quantity of Ba (1.4-8.3%), S (0.7%) and Sn (35.3%) was found. In the Au-Pd alloy-ceramic interface, 56.4-69.9% O-2 followed by 15.6-26.2% Si, 3.9-10.9% K, 2.8-6% Na, 4.4-9.6% Al and 0-0.04% Mg was observed. Significance. After thermal-cycling for 6000 times and mechanical-cycling for 20,000 times, Triceram-cpTi combination presented the least decrease among other ceramic-alloy combinations when compared to the mean bond strength results with Au-Pd alloy-Vita Omega 900 combination. (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:221 / 231
页数:11
相关论文
共 8 条
  • [1] Influence of thermal and mechanical cycling on the flexural strength of ceramics with titanium or gold alloy frameworks
    Oyafuso, Denise Kanashiro
    Ozcan, Mutlu
    Bottino, Marco Antonio
    Itinoche, Marcos Koiti
    DENTAL MATERIALS, 2008, 24 (03) : 351 - 356
  • [2] Evaluation of Mechanical Properties of Titanium Alloy after Thermal Oxidation Process
    Anil Kumar
    Manoj Kumar Kushwaha
    Mohammad Israr
    Rakesh Kumar
    Transactions of the Indian Institute of Metals, 2020, 73 : 1373 - 1381
  • [3] Evaluation of Mechanical Properties of Titanium Alloy after Thermal Oxidation Process
    Kumar, Anil
    Kushwaha, Manoj Kumar
    Israr, Mohammad
    Kumar, Rakesh
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2020, 73 (05) : 1373 - 1381
  • [4] In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion
    Sartori, IAD
    Ribeiro, RF
    Francischone, CE
    de Mattos, MDC
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (02): : 132 - 138
  • [5] Characterization of the Interface Between the Bulk Glass Forming Alloy Zr41Ti14Cu12Ni10Be23 with Pure Metals and Ceramics
    Jan Schroers
    Konrad Samwer
    Frigyes Szuecs
    William L. Johnson
    Journal of Materials Research, 2000, 15 : 1617 - 1621
  • [6] Characterization of the interface between the bulk glass forming alloy Zr41Ti14Cu12Ni10Be23 with pure metals and ceramics
    Schroers, J
    Samwer, K
    Szuecs, F
    Johnson, WL
    JOURNAL OF MATERIALS RESEARCH, 2000, 15 (07) : 1617 - 1621
  • [7] Interface Characterization, Thermal and Mechanical Properties Evaluation of Cu, Zn, and Sn Interlayered Al5.2Si alloy-SS 304 Bimetallic Castings
    V. Raja
    M. Kavitha
    Silicon, 2023, 15 : 8009 - 8018
  • [8] Interface Characterization, Thermal and Mechanical Properties Evaluation of Cu, Zn, and Sn Interlayered Al5.2Si alloy-SS 304 Bimetallic Castings
    Raja, V.
    Kavitha, M.
    SILICON, 2023, 15 (18) : 8009 - 8018