Venturi-Electrosonic Spray Ionization Cataluminescence Sensor Array for Saccharides Detection

被引:46
|
作者
Han, Jiaying [1 ]
Han, Feifei [1 ]
Ouyang, Jin [1 ]
Li, Quanmin [2 ]
Na, Na [1 ]
机构
[1] Beijing Normal Univ, Coll Chem, Beijing 100875, Peoples R China
[2] Gen Hosp Second Artillery, Dept Endocrinol, Beijing 100088, Peoples R China
关键词
AMBIENT MASS-SPECTROMETRY; BENZENE; PLASMA; SYSTEM;
D O I
10.1021/ac400948k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a Venturi electrosonic spray ionization (V-ESSI) cataluminescence (CTL) sensor array was reported for discriminating saccharides in solution. Integrating electrosonic spray ionization (ESSI), a liquid system of Venturi self-pumping injection for the CTL reaction, was fabricated for enhancing CTL reactivity of aqueous samples. Comparing with simple Venturi injection by air and Venturi easy ambient sonic-spray ionization without electric assistance (V-EASI), the remarkable enhancement of CTL signals resulted from V-ESSI. This system showed higher cross-reactive CTL responses catalyzed by alkaline earth metal-nanomaterials than other catalysts, giving different signals for a given saccharide on different catalysts and different responses for different saccharides on the same catalyst. Then, a 4 x 2 CTL sensor array was used for obtaining "fingerprints" of distinct CTL response patterns. Analyzed by linear discriminant analysis (LDA), this V-ESSI CTL sensor array not only achieved the well discrimination of different saccharides (99.9% of total variation) but also discriminated four groups of urine sugar-level for urine samples from diabetic patients (98.1% of discrimination accuracy). It had good reproducibility and gave a linear range of 22.5-67558 mu g/mL (R > 0.99) for xylose with a detection limit of 7.4 mu g/mL on MgO. As a new artificial tongue, this system provided a simple, rapid, low cost, low energy consumption, and environmentally friendly pathway for aqueous sample discrimination. It has dramatically expanded applications of the CTL-based senor array and will be applicable to clinical diagnoses, environment monitoring, industrial controls, food industry, and various marine monitoring.
引用
收藏
页码:7738 / 7744
页数:7
相关论文
共 8 条
  • [1] A research on detection and identification of volatile organic compounds utilizing cataluminescence-based sensor array
    Li, Bo
    Liu, Juefu
    Shi, Guolong
    Liu, Jinhuai
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 1167 - 1172
  • [2] Colorimetric sensor array–smartphone–remote server coupling system for rapid detection of saccharides in beverages
    Yiran Cui
    Tong Chen
    Bingxiang Li
    Xin Liu
    Jinchen Xia
    Juan Han
    Yanling Wu
    Min Yang
    Journal of the Iranian Chemical Society, 2018, 15 : 1085 - 1095
  • [3] A portable embedded drug precursor gas detection and identification device based on cataluminescence-based sensor array
    Sha, Wen
    Cui, Danfeng
    Li, Bo
    Wang, Qihui
    Wang, Yuhuai
    Zheng, Chunhou
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 200 : 132 - 139
  • [4] Colorimetric sensor array-smartphone-remote server coupling system for rapid detection of saccharides in beverages
    Cui, Yiran
    Chen, Tong
    Li, Bingxiang
    Liu, Xin
    Xia, Jinchen
    Han, Juan
    Wu, Yanling
    Yang, Min
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (05) : 1085 - 1095
  • [5] Selective Detection of NO and NO2 with CNTs-Based Ionization Sensor Array
    Song, Hui
    Li, Kun
    Wang, Chang
    MICROMACHINES, 2018, 9 (07):
  • [6] Temperature Compensation With Highly Integrated Ionization Sensor Array Used in Simultaneous Detection of Mixed Gases
    Cheng, Zhenzhen
    Zhang, Yong
    Muhammad, Waqas
    Hao, Yunhe
    Tang, Yujie
    Sun, Lili
    Wang, Di
    Zhou, Jintang
    Wang, Ruizhe
    Deng, Yuangang
    Li, Yunjia
    Geng, Li
    Han, Wen
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (01) : 911 - 920
  • [7] In-depth phytochemical and biological studies on potential AChE inhibitors in red and zigzag clover dry extracts using reversed-phase liquid chromatography (RP-LC) coupled with photodiode array (PDA) and electron spray ionization-quadrupole/time of flight-mass spectrometric (ESI-QToF/MS-MS) detection and thin-layer chromatography-bioautography
    Maciejewska-Turska, Magdalena
    Zgorka, Grazyna
    FOOD CHEMISTRY, 2022, 375
  • [8] In-depth phytochemical and biological studies on potential AChE inhibitors in red and zigzag clover dry extracts using reversed–phase liquid chromatography (RP-LC) coupled with photodiode array (PDA) and electron spray ionization-quadrupole/time of flight-mass spectrometric (ESI-QToF/MS-MS) detection and thin-layer chromatography-bioautography
    Maciejewska-Turska, Magdalena
    Zgórka, Grażyna
    Food Chemistry, 2022, 375