Reproducibility of isokinetic knee testing using the novel isokinetic SMM iMoment dynamometer

被引:18
|
作者
Kambic, Tim [1 ,2 ]
Lainscak, Mitja [3 ,4 ]
Hadzic, Vedran [2 ]
机构
[1] Gen Hosp Murska Sobota, Dept Res & Educ, Murska Sobota, Slovenia
[2] Univ Ljubljana, Fac Sport, Lab Sports & Med Diagnost, Ljubljana, Slovenia
[3] Gen Hosp Murska Sobota, Div Cardiol, Murska Sobota, Slovenia
[4] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
来源
PLOS ONE | 2020年 / 15卷 / 08期
关键词
RELIABILITY; STRENGTH; EXTENSION; QUADRICEPS; MOTION;
D O I
10.1371/journal.pone.0237842
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Isokinetic dynamometry is the gold standard for testing maximal strength in elite sport and rehabilitation settings. To be clinically useful, such tests should be valid and reliable. Despite some evidence regarding the relative test vs retest reliability of knee dynamometry, there is still a paucity of research regarding the absolute reliability parameters. The purpose of this study was to assess the absolute and relative intra-device reproducibility of isokinetic knee flexion and extension using the novel SMM iMoment dynamometer. A total of 19 participants (13 males and 6 females, aged 24 (2) years, height 178 (9) cm and weight 76 (11) kg) performed two identical knee isokinetic tests with at least a week of rest between measurements. Peak torque of knee extension and flexion were determined at 60 degrees/s. Moderate (0.892) to excellent (0.988) relative reliability using the intraclass correlation coefficient (ICC) was obtained for peak knee torque. Absolute reliability assessed with a standard error of measurement (SEM %) was low, ranging from 2.54% to 6.93%, whereas the smallest real difference (SRD %) was moderate, ranging from 7.04% to 19.22%. Furthermore, there were no significant correlations between means and differences of two measurements, and Bland-Altman plots also showed no signs of heteroscedasticity. Our measurement protocol established the moderate to excellent reliability of the novel SMM iMoment isokinetic dynamometer. Therefore, this dynamometer can be applied in sport rehabilitation settings to measure maximal knee strength.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Testing a novel isokinetic dynamometer constructed using a 1080 Quantum
    Whinton, Alanna K.
    Thompson, Kyle M. A.
    Power, Geoffrey A.
    Burr, Jamie F.
    [J]. PLOS ONE, 2018, 13 (07):
  • [2] Reliability and Validity of a Novel Isokinetic Knee Dynamometer System
    Riemann, Bryan L.
    Watson, Matthew D.
    Davies, George J.
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2021, 23 (04) : 107 - 116
  • [3] Reproducibility and reliability of measurements using a linear isokinetic dynamometer, Aristokin®
    Lenaerts, A
    Verbruggen, LA
    Duquet, W
    [J]. JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2001, 41 (03): : 362 - 370
  • [4] Concentric and eccentric isokinetic knee extension: A reproducibility study using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Koesters, Alexander
    Mueller, Erich
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (01) : 31 - 35
  • [5] Measurement of Proprioception of the Knee in Hemiplegic Patients Using an Isokinetic Dynamometer
    Hwang, Ji Sun
    Lee, Dong Seok
    Cho, Yun Jeong
    Han, Na Mi
    Kim, Hyun Dong
    [J]. ANNALS OF REHABILITATION MEDICINE-ARM, 2010, 34 (01): : 27 - 33
  • [6] Reproducibility for isometric and isokinetic maximum knee flexion and extension measurements using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Wiesinger, Hans-Peter
    Koesters, Alexander
    Mueller, Erich
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (03) : 149 - 153
  • [7] PLANTAR FLEXOR STRENGTH TESTING USING CYBEX ISOKINETIC DYNAMOMETER
    FALKEL, J
    [J]. PHYSICAL THERAPY, 1978, 58 (07): : 847 - 850
  • [8] Comparison of values generated during isokinetic-testing of the knee extensor and flexor muscles using the cybex 6000 and biodex 3 isokinetic dynamometer
    Keilani, M. Y.
    Posch, M.
    Zorn, C.
    Knoetig, M.
    Pircher, M.
    Quittan, M.
    Fialka-Moser, V.
    Jirasek, U.
    Crevenna, R.
    [J]. PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2007, 17 (06) : 327 - 333
  • [9] Reproducibility of an Isokinetic Strength-Testing Protocol of the Knee and Ankle in Older Adults
    Hartmann, Antonia
    Knols, Ruud
    Murer, Kurt
    de Bruin, Eling D.
    [J]. GERONTOLOGY, 2009, 55 (03) : 259 - 268
  • [10] EVALUATION OF TOTAL KNEE ARTHROPLASTY USING ISOKINETIC TESTING