Full-scale test of Direct-buried Cable in Sand under Repetitive Loading

被引:0
|
作者
Chong, Song -Hun [1 ]
An, Jun-Beom [2 ]
Cho, Gye-Chun [2 ]
机构
[1] Sunchon Natl Univ, Dept Civil Engn, Sunchon 57922, South Korea
[2] Korea Adv Inst Sci & Technol KAIST, Dept Civil & Environm Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
Direct-buried cable construction; Repetitive loads; Full-scale chamber; Shear wave velocity; Miniature electrical cone; PIPES;
D O I
10.1016/j.trgeo.2022.100877
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Direct-buried cable construction can minimize cumbersome processes, thereby decreasing construction time and cost. However, there is no regulation on burial depth that consider the long-term performance of backfilling soil for direct-buried cables. This study examines the mechanical response of direct-buried cables subjected to re-petitive loads. This experimental study uses a full-scale chamber to replicate field construction. The stress on the cable, vertical displacement on the surface, and shear wave velocity between loading plate and cable are continuously monitored during 10,000 repetitive loading cycles. A miniature electrical cone is used to indirectly quantify the initial relative compaction. Repetitive loading densifies the soil around the cable, increasing stress on the cable and accumulating vertical strain. The trends are more pronounced with lower initial relative compaction. The shear wave velocity increases during repetitive loading, suggesting a change in the earth pressure coefficient. Applied stress - vertical strain allows the estimation of resilient modulus. These observations will provide a better understanding of the mechanical response of backfilling soil. Additionally, the uniaxial compression test of the underground power cable made for direct burial is conducted to measure the displace-ment of the cable insulator under the field condition obtained from the full-scale test. Then mechanical stability of the cable is investigated based on the axial displacement of the cable insulator.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Full-scale embankment failure test under simulated train loading
    Lehtonen, V. J.
    Meehan, C. L.
    Laensivaara, T. T.
    Mansikkamaeki, J. N.
    GEOTECHNIQUE, 2015, 65 (12): : 961 - 974
  • [2] Full-scale test on emergency pavement repair under aeroplane loading
    Zhang, Jun
    Xu, Wei
    Gao, Peiwei
    Weng, Xingzhong
    Su, Lihai
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-TRANSPORT, 2022, 177 (02) : 101 - 113
  • [3] Full-scale test of composite frame under large cyclic loading
    Nakashima, Masayoshi
    Matsumiya, Tomohiro
    Suita, Keiichiro
    Zhou, Feng
    JOURNAL OF STRUCTURAL ENGINEERING, 2007, 133 (02) : 297 - 304
  • [4] Full-scale load test of a sand-jack
    Thurston, H.M.
    Practice Periodical on Structural Design and Construction, 2001, 6 (03) : 116 - 118
  • [5] Full-scale mud pumping test of ballastless trackbed under train loading
    Wan, Zhangbo
    Xu, Weichang
    Bian, Xuecheng
    Chen, Yunmin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 174
  • [6] SELF-SEALING DIRECT-BURIED 600 VOLT SECONDARY CABLE
    LAWSON, JH
    KONG, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 45 - 49
  • [7] FULL-SCALE TEST OF FRICTION DAMPER FOR CABLE VIBRATION MITIGATION
    Zhou, Hai-Jun
    Sun, Li-Min
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1277 - 1282
  • [8] PERFORMANCE OF FULL-SCALE PAVEMENTS UNDER ACCELERATED LOADING
    SEBAALY, PE
    ANDERSON, DA
    TABATABAEE, N
    JOURNAL OF TRANSPORTATION ENGINEERING-ASCE, 1989, 115 (04): : 370 - 388
  • [9] Full-scale field testing of a precast concrete buried arch bridge with steel outriggers: Field loading test
    Jeon, Seok Hyeon
    Yim, Hong Jae
    Huh, Jungwon
    Cho, Kwang-Il
    Ahn, Jin-Hee
    ENGINEERING STRUCTURES, 2021, 242
  • [10] Full-scale testing of buried extensible pipes subject to axial soil loading
    Wijewickreme, D.