Development of a Two-Way Coupled Eulerian-Lagrangian Computational Magnetic Nanoparticle Targeting Model for Pulsatile Flow in a Patient-Specific Diseased Left Carotid Bifurcation Artery

被引:18
|
作者
Hewlin, Rodward L., Jr. [1 ,2 ]
Ciero, Ashley [1 ]
Kizito, John P. [3 ]
机构
[1] Univ North Carolina Charlotte, Dept Engn Technol & Construct Management ETCM, Charlotte, NC 28223 USA
[2] Univ North Carolina Charlotte, CBES, Charlotte, NC USA
[3] North Carolina Agr & Tech State Univ, Dept Mech Engn, Greensboro, NC USA
基金
美国国家航空航天局;
关键词
Capture efficiency; Carotid artery; Diseased; Eulerian; Lagrangian; Magnetic drug targeting; Magnetite; Patient-specific; Pulsatile flow; NUMERICAL-SIMULATION; PARTICLE CAPTURE; DELIVERY; STENTS;
D O I
10.1007/s13239-019-00411-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeThe aim of the present work is to present the development of a computational two-way coupled (fluid and particle coupled) magnetic nanoparticle targeting model to investigate the efficacy of magnetic drug targeting (MDT) in a patient-specific diseased left carotid bifurcation artery. MDT of therapeutic agents using multifunctional carrier particles has the potential to provide effective treatment of both cancer and cardiovascular disease by enabling a variety of localized treatment and diagnostic modalities while minimizing side effects.MethodsA computational model is developed to analyze pulsatile blood flow, particle motion, and particle capture efficiency in a diseased left carotid bifurcation artery using the magnetic properties of magnetite (Fe3O4) and equations describing the magnetic forces acting on particles produced by an external cylindrical electromagnetic coil. A Eulerian-Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of particles under the influence of a magnetic field (B-r=2T). Particle diameter sizes of 20nm-4m in diameter were considered.ResultsThe computational simulations demonstrate that the greatest particle capture efficiency results for particle diameters within the micron range, specifically 4 mu m in regions where flow separation and vortices are at a minimum. It was also determined that the capture efficiency of particles decreases substantially with particle diameter, especially in the superparamagnetic regime. Particles larger than 2m were targeted and captured at the desired location by the external magnetic field, and the largest capture efficiency observed was approximately 98%.ConclusionThe simulation results presented in the present work have shown to yield favorable capture efficiencies for micron range particles and a potential for enhancing capture efficiency of superparamagnetic particles in smaller arteries and/or using magnetized implants such as cardiovascular stents. The present work presents results for justifying further investigation of MDT as a treatment technique for cardiovascular disease.
引用
收藏
页码:299 / 313
页数:15
相关论文
共 4 条