Application of a novel diol-based porous organic polymer to the determination of trace-level tetracyclines in water

被引:5
|
作者
Cui, Changzheng [1 ]
Cao, Zan [1 ]
Zhang, Shenping [2 ]
Hu, Yaru [1 ]
Jiang, Lei [3 ]
Yao, Shijie [1 ]
Ye, Hui [3 ]
Zhou, Yanbo [1 ]
Hu, Jun [2 ]
Lin, Kuangfei [1 ]
Zhang, Tian-Yang [1 ]
机构
[1] East China Univ Sci & Technol, State Environm Protect Key Lab Environm Risk Asse, Sch Resources & Environm Engn, Shanghai 200237, Peoples R China
[2] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China
[3] Natl Engn Res Ctr Urban Water Resources, Shanghai 200082, Peoples R China
基金
中国博士后科学基金;
关键词
TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; MULTIRESIDUE ANALYTICAL METHOD; SPE-LC-MS/MS; LIQUID-CHROMATOGRAPHY; WASTE-WATER; DRINKING-WATER; SURFACE-WATER; VETERINARY ANTIBIOTICS; PHARMACEUTICALS;
D O I
10.1039/c8ay02790k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The solid phase extraction (SPE) method is often used to enrich trace antibiotics in water before analysis by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), but the improvement of extraction efficiency has always been the hot issue in this method, which may be realized by developing new SPE materials and optimizing extraction conditions. Tetracyclines (TCs) are a class of common antibiotics, but appropriate SPE materials specifically used to detect them are lacking. Common SPE materials show low and unstable recoveries during the extraction and detection of TCs. In this study, a novel diol-based porous organic polymer (NTdiol-POP) was used as a new SPE material to detect trace TCs in water. This material has specific adsorptive properties for TCs via hydrogen bonds, electrostatic attractive interactions, and p-p interactions. The results show that the NTdiol-POP cartridges have higher recoveries (83.3-118.1%) for determining TCs than common SPE cartridges. Under optimum SPE conditions using NTdiol-POP, TCs were adsorbed at pH 5.0 and eluted with a solution of formic acid/methanol (7%/93%, v/v). Meanwhile, chromatographic separation conditions and MS/MS parameters in multiple reaction monitoring (MRM) mode were optimized to improve the sensitivity and specificity of the instrumental analysis. The limit of detection varied from 0.078 to 2.18 ng L-1, while the limit of quantification varied from 0.26 to 7.25 ng L-1. An assessment of the matrix effects in drinking water exhibited a slight signal variation for most TCs (-8.4% to 2.5%) except oxytetracycline, for which the detection signals were enhanced by 27.0%. The proposed method was successfully applied to determine the trace TCs in three reservoirs of East China.
引用
收藏
页码:2473 / 2481
页数:9
相关论文
共 50 条
  • [1] Novel catalytic spectrophotometric procedure for the determination of trace-level aluminium
    He, RH
    Wang, JH
    ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 241 - 245
  • [2] Induced-fit adsorption of diol-based porous organic polymers for tetracycline removal
    Zhang, Shenping
    Li, Yankai
    Shi, Chunhong
    Guo, Fangyuan
    He, Congze
    Cao, Zan
    Hu, Jun
    Cui, Changzheng
    Liu, Honglai
    CHEMOSPHERE, 2018, 212 : 937 - 945
  • [3] Trace-level determination of pesticides in water by means of liquid and gas chromatography
    Geerdink, RB
    Niessen, WMA
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2002, 970 (1-2) : 65 - 93
  • [4] Novel potentiometric sensor for the trace-level determination of Zn2+ based on a new nanographene/ion imprinted polymer composite
    Shirzadmehr, Ali
    Rezaei, Mosayeb
    Bagheri, Hasan
    Khoshsafar, Hosein
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (10) : 929 - 944
  • [5] Extractive scintillating polymer sensors for trace-level detection of uranium in contaminated ground water
    Duval, Christine E.
    DeVol, Timothy A.
    Husson, Scott M.
    ANALYTICA CHIMICA ACTA, 2016, 947 : 1 - 8
  • [6] TRACE-LEVEL DETERMINATION OF BROMATE IN OZONATED DRINKING-WATER USING ION CHROMATOGRAPHY
    JOYCE, RJ
    DHILLON, HS
    JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) : 165 - 171
  • [7] MIMS FOR TRACE-LEVEL DETERMINATION OF ORGANIC ANALYTES IN ONLINE PROCESS MONITORING AND ENVIRONMENTAL-ANALYSIS
    BAUER, SJ
    COOKS, RG
    AMERICAN LABORATORY, 1993, 25 (16) : 36 - &
  • [8] Zeolite based microconcentrators for volatile organic compounds sensing at trace-level: fabrication and performance
    Almazan, Fernando
    Pellejero, Ismael
    Morales, Alberto
    Urbiztondo, Miguel A.
    Sese, Javier
    Pilar Pina, M.
    Santamaria, Jesus
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (08)
  • [9] GAS-CHROMATOGRAPHIC TRACE-LEVEL DETERMINATION OF VOLATILE ORGANIC SULFIDES AND SELENIDES AND OF METHYL-IODIDE IN ATLANTIC SURFACE-WATER
    TANZER, D
    HEUMANN, KG
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 48 (01) : 17 - 31
  • [10] Development of analytical procedures for trace-level determination of polybrominated diphenyl ethers and tetrabromobisphenol A in river water and sediment
    Labadie, Pierre
    Tlili, Khawla
    Alliot, Fabrice
    Bourges, Catherine
    Desportes, Annie
    Chevreuil, Marc
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (02) : 865 - 875