Transcranial magnetic stimulation patterns in heterogeneous brain tissue: focality, reproducibility and true sham stimulation

被引:0
|
作者
Toschi, N. [1 ]
Guerrisi, M.
Welt, T. [2 ]
Keck, M. E. [2 ]
机构
[1] Univ Roma Tor Vergata, Fac Med, Sez Fis Med, Dip Biopatol, Rome, Italy
[2] Psychiatrische Universitaetsklinik Zuerich, Zurich, Switzerland
关键词
figure-8; coil; magnetic brain stimulation; brain conductivity;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcranial magnetic stimulation (TMS) has been gaining status as an innovative research and possibly therapeutic tool for non-invasive stimulation of brain tissue. However, optimal values of key stimulation parameters such as coil size, shape and orientation and current pulse characteristics remain largely undetermined. Further, the influence of brain size and shape as well as of the strong heterogeneity of brain tissue on stimulation efficacy is unclear. In order to calculate the current density distribution induced in brain tissue by TMS, a complete set of MRI images of the human brain is discretised over a cubic mesh, constructing a spatial map for tissue electrical conductivity. The magnetic induction field is calculated as a function of coil geometry and position as well as incoming current pulse characteristics, after which Maxwell's equations in integral form are discretised and solved over the mesh by a successive overrelaxation procedure. Findings are validated by recording motor evoked potentials from the right abductor pollicis brevis muscle from a healthy subject in a stereotaxic framework. The inhomogeneous electrical characteristics of brain tissue are seen to significantly influence stimulation patterns, as a symmetrical primary electric field results in a highly asymmetrical current density distribution. Also, several commonly used sham stimulation configurations elicit conductive patterns which achieve up to 40% of the strength of real stimulation. Further, variations in coil position of the order of a 7 degree tilt, which are expected to occur in non-stereotaxic stimulation, can alter the stimulation intensity by up to 38%. Knowledge of coil specifications alone is clearly not sufficient to control stimulation conditions. In accordance with our findings, several clinical studies observe measurable effects during sham stimulation, and the sensitivity of stimulation intensity to tiny coil rotations afford a partial explanation for the poor reproducibility and partial disagreements observed across TMS studies. Our findings bear direct relevance to any application of TMS, both investigative and therapeutic.
引用
收藏
页码:2685 / +
页数:2
相关论文
共 50 条
  • [1] Transcranial magnetic stimulation in heterogeneous brain tissue: Clinical impact on focality, reproducibility and true sham stimulation
    Toschi, Nicola
    Welt, Tobias
    Guerrisi, Maria
    Keck, Martin E.
    JOURNAL OF PSYCHIATRIC RESEARCH, 2008, 43 (03) : 255 - 264
  • [2] Sham Validation in Transcranial Magnetic Stimulation
    Padala, Kalpana P.
    Thombre, Vaishali
    Dennis, Richard A.
    Mennemeier, Mark S.
    Lensing, Shelly Y.
    Padala, Prasad R.
    AMERICAN JOURNAL OF GERIATRIC PSYCHIATRY, 2018, 26 (03): : S157 - S157
  • [3] A reconstruction of the conductive phenomena elicited by transcranial magnetic stimulation in heterogeneous brain tissue
    Toschi, Nicola
    Welt, Tobias
    Guerrisi, Maria
    Keck, Martin E.
    PHYSICA MEDICA, 2008, 24 (02) : 80 - 86
  • [4] Sham transcranial magnetic stimulation using electrical stimulation of the scalp
    Mennemeier, Mark S.
    Triggs, William J.
    Chelette, Kenneth C.
    Woods, A. J.
    Kimbrell, Timothy A.
    Dornhoffer, John L.
    BRAIN STIMULATION, 2009, 2 (03) : 168 - 173
  • [5] Influence of Brain Scalp Distance on Focality of the Quadruple Butterfly Coil for Transcranial Magnetic Stimulation
    Afuwape, Oluwaponmile F.
    Boldrey, Joseph
    Rastogi, Priyam
    Bentil, Sarah A.
    Jiles, David C.
    IEEE TRANSACTIONS ON MAGNETICS, 2021, 57 (02)
  • [6] A New Transcranial Magnetic Stimulation Coil Design to Improve the Focality
    Ai, Qingyao
    Li, Jiangtao
    Li, Meng
    Jiang, Wei
    Wang, Bo
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1391 - 1395
  • [7] Focality assessment in transcranial magnetic stimulation with double and cone coils
    Lontis, Eugen R.
    Voigt, Michael
    Struijk, Johannes J.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2006, 23 (05) : 462 - 471
  • [8] Transcranial Magnetic Stimulation-coil design with improved focality
    Rastogi, P.
    Lee, E. G.
    Hadimani, R. L.
    Jiles, D. C.
    AIP ADVANCES, 2017, 7 (05):
  • [9] Effect of coil size on transcranial magnetic stimulation (TMS) focality
    Bagherzadeh, Hedyeh
    Choa, Fow-Sen
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY XV, 2019, 11020
  • [10] Estimation of the Focality of Coils and Quality of Stimulation of Biological Tissues During Transcranial Magnetic Stimulation
    Carmona, Ivan C.
    Afuwape, Oluwaponmile F.
    Jiles, David C.
    Hadimani, Ravi L.
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (02)