Video-oculography to evaluate Dynamic Visual Acuity to subjects with Intraocular Lens implant as a treatment for high refractive errors

被引:0
|
作者
Sanchez Sanchez, Anabel S. [1 ]
Suaste Gomez, Ernesto [1 ]
机构
[1] Inst Politecn Nacl, Ctr Invest & Estudios Avanzados, Secc Bioelect, Dept Ingn Elect, Mexico City 07738, DF, Mexico
关键词
Dynamic Visual Acuity; IOL; Lovie-Baley chart;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this paper is to describe the methodology based on video-oculography used to evaluate changes in Dynamic Visual Acuity (DVA) in subjects with Intraocular Lens (IOL) implant. This is done before and later of the implant. The luminance conditions were established. The visual stimulus to show is copied from Lovie-Baley chart. Those are projected in front of the subject starting in a movement frequency of 0.1 Hz. It is gradually increasing until the subject refers is no possible to appreciate the stimulus form. A preliminary study is done in two subjects. The suggested methodology let to know frequency changes in DVA in subjects with IOL implant.
引用
收藏
页码:655 / 657
页数:3
相关论文
共 6 条
  • [1] Dynamic visual acuity using video-oculography
    Zúñiga, A
    García, N
    Rodríguez, D
    Suaste, E
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3229 - 3232
  • [2] Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Montes-Mico, Robert
    Amhaz, Hussein
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (02): : 199 - 204
  • [3] The Role of Phakic Intraocular Lens Implants in Treatment of High-Refractive Errors and Amblyopia in Children
    Moran, Sarah
    O'Keefe, Michael
    OPHTHALMOLOGY AND THERAPY, 2013, 2 (01) : 3 - 9
  • [4] The Role of Phakic Intraocular Lens Implants in Treatment of High-Refractive Errors and Amblyopia in Children
    Sarah Moran
    Michael O’Keefe
    Ophthalmology and Therapy, 2013, 2 (1) : 3 - 9
  • [5] A novel standardized test system to evaluate dynamic visual acuity post trifocal or monofocal intraocular lens implantation: a multicenter study
    Ren, Xiaotong
    Wang, Yuexin
    Wang, Dengting
    Wu, Baohua
    Wu, Lei
    Xu, Yanhui
    Yang, Jiarui
    Chen, Zhimin
    Li, Xuemin
    EYE, 2020, 34 (12) : 2235 - 2241
  • [6] A novel standardized test system to evaluate dynamic visual acuity post trifocal or monofocal intraocular lens implantation: a multicenter study
    Xiaotong Ren
    Yuexin Wang
    Dengting Wang
    Baohua Wu
    Lei Wu
    Yanhui Xu
    Jiarui Yang
    Zhimin Chen
    Xuemin Li
    Eye, 2020, 34 : 2235 - 2241