Use of CLYC Spectrometer in Counter-Terrorism Applications

被引:2
|
作者
Ing, H. [1 ]
Smith, M. B. [1 ]
Koslowsky, M. R. [1 ]
Andrews, H. R. [1 ]
机构
[1] Bubble Technol Ind Inc, Chalk River, ON, Canada
关键词
Radiation Detection; CLYC; Counter-terrorism; GEANT4;
D O I
10.1117/12.2181675
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new scintillator crystal, now known as CLYC (Cs2LiYCl6:Ce), has been under development for over 15 years (1). It was primarily of interest for radiation detection applications because of its good energy resolution for gamma rays (< 4% for 662 keV gamma rays) and its capability for detection of thermal neutrons. The pulse shapes of the signals from the two radiations are different, which allow them to be separated electronically, permitting simultaneous detection of gamma rays and neutrons. The crystal is now commercially available. Early investigations of the neutron response by the current authors ((2)) revealed that CLYC also responds to fast neutrons. In fact, the good energy resolution of the response under monoenergetic neutron irradiations showed that CLYC was an excellent high-energy neutron spectrometer. This discovery has great impact on the field of neutron spectroscopy, which has numerous, although often specialized, applications. This presentation focuses on applications in counter-terrorism scenarios where neutrons may be involved. The relative importance of the fast neutron response of CLYC, compared to the thermal and gamma-ray response, will be discussed for these scenarios.
引用
收藏
页数:14
相关论文
共 50 条