Sentinel Node Biopsy is Indicated for Thin Melanomas ≥0.76 mm

被引:54
|
作者
Han, Dale [1 ]
Yu, Daohai [2 ]
Zhao, Xiuhua [2 ]
Marzban, Suroosh S. [1 ]
Messina, Jane L. [1 ,3 ,4 ,5 ]
Gonzalez, Ricardo J. [1 ,3 ,6 ]
Cruse, C. Wayne [1 ,3 ,7 ]
Sarnaik, Amod A. [1 ,3 ,6 ]
Puleo, Christopher [1 ]
Sondak, Vernon K. [1 ,3 ,6 ]
Zager, Jonathan S. [1 ,3 ,6 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Dept Cutaneous Oncol, Tampa, FL USA
[2] H Lee Moffitt Canc Ctr & Res Inst, Dept Biostat, Tampa, FL USA
[3] Univ S Florida, Morsani Coll Med, Dept Oncol Sci, Tampa, FL USA
[4] Univ S Florida, Morsani Coll Med, Dept Pathol, Tampa, FL USA
[5] Univ S Florida, Morsani Coll Med, Dept Dermatol, Tampa, FL USA
[6] Univ S Florida, Dept Surg, Morsani Coll Med, Tampa, FL 33620 USA
[7] Univ S Florida, Dept Plast Surg, Morsani Coll Med, Tampa, FL 33620 USA
关键词
PRIMARY CUTANEOUS MELANOMA; AMERICAN JOINT COMMITTEE; EARLY-STAGE MELANOMA; LYMPH-NODE; MITOTIC RATE; POSITIVITY; PREDICTORS; LYMPHADENECTOMY; METASTASIS; REGRESSION;
D O I
10.1245/s10434-012-2469-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A consensus for which patients with thin melanomas (a parts per thousand currency sign1 mm) should undergo sentinel lymph node biopsy (SLNB) is not established. We describe a large single institution experience with SLNB for thin melanomas to determine factors predictive of nodal metastases. Retrospective review from 2005 to 2010 identified 271 patients with thin melanomas who underwent SLNB, along with 13 additional patients not treated with SLNB who developed a nodal recurrence as first site of recurrence. Clinicopathologic characteristics were correlated with nodal status and outcome. Median age was 55 years, and 53 % of patients were male. Median Breslow thickness was 0.85 mm. Overall, a positive sentinel lymph node (SLN) was found in 22 (8.1 %) of 271 cases; 8.4 % of melanomas a parts per thousand yen0.76 mm were SLN positive with 5 % of T1a melanomas a parts per thousand yen0.76 mm and 13 % of T1b melanomas a parts per thousand yen0.76 mm having SLN metastases. Only two of 33 highly selected patients with melanomas < 0.76 mm (both T1b) had a positive SLN. Logistic regression analysis demonstrated that mitotic rate a parts per thousand yen1/mm(2) significantly correlated with nodal disease (p < 0.05) and ulceration correlated with SLN metastases (p < 0.05). Median follow-up was 2.1 years. Overall survival did not differ between positive and negative SLN patients (p = 0.53) but was worse for patients presenting with a nodal recurrence (p < 0.01). SLN metastases were seen in 8.4 % of thin melanomas a parts per thousand yen0.76 mm, including 5 % of T1a melanomas a parts per thousand yen0.76 mm. We believe these rates are sufficient to justify consideration of SLNB in these patients, while the indications for SLNB in melanomas < 0.76 mm remain to be defined.
引用
收藏
页码:3335 / 3342
页数:8
相关论文
共 50 条
  • [1] Sentinel Node Biopsy is Indicated for Thin Melanomas ≥0.76 mm
    Dale Han
    Daohai Yu
    Xiuhua Zhao
    Suroosh S. Marzban
    Jane L. Messina
    Ricardo J. Gonzalez
    C. Wayne Cruse
    Amod A. Sarnaik
    Christopher Puleo
    Vernon K. Sondak
    Jonathan S. Zager
    Annals of Surgical Oncology, 2012, 19 : 3335 - 3342
  • [2] Sentinel Node Biopsy is Indicated for Thin Melanomas ≥0.76mm
    Han, D.
    Marzban, S. S.
    Yu, D.
    Zhao, X.
    Messina, J. L.
    Gonzalez, R. J.
    Cruse, C. W.
    Sarnaik, A.
    Puleo, C.
    Sondak, V. K.
    Zager, J. S.
    ANNALS OF SURGICAL ONCOLOGY, 2012, 19 : S24 - S25
  • [3] The Sentinel Lymph Node Biopsy in thin melanoma (Breslow ≤ 0.75 mm and 0.76-1.0 mm)
    Kechagias, G.
    Marra, A.
    Karonidis, A.
    Kyriopoulos, E.
    Tsoutsos, D.
    MELANOMA RESEARCH, 2016, 26 : E41 - E41
  • [4] Indications for sentinel lymph node biopsy in thin melanomas
    J. Vaquerano
    W. Kraybill
    R. Cheney
    J. M. Kane
    Annals of Surgical Oncology, 2004, 11 : S77 - S78
  • [5] Sentinel lymph node biopsy in patients with thin melanomas
    Cecchi, Roberto
    Buralli, Lauro
    Innocenti, Steania
    De Gaudio, Cataldo
    JOURNAL OF DERMATOLOGY, 2007, 34 (08): : 512 - 515
  • [6] Indications for sentinel lymph node biopsy in thin melanomas
    Vaquerano, J
    Kraybill, W
    Cheney, R
    Kane, JM
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (02) : S77 - S78
  • [7] Thin melanomas (&lt;1 mm) and new NICE guidance for sentinel lymph node biopsy
    Dunne, J. A.
    Odili, J.
    Powell, B. W. E. M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2016, 69 (02): : 285 - 286
  • [8] Wisely choosing thin melanomas for sentinel lymph node biopsy
    Piscioli, Francesco
    Pusiol, Teresa
    Roncati, Luca
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2017, 76 (01) : E25 - E25
  • [9] Cost-effectiveness of sentinel lymph node biopsy in thin melanomas
    Agnese, DM
    Abdessalam, SF
    Burak, WE
    Magro, CM
    Pozderac, RV
    Walker, MJ
    SURGERY, 2003, 134 (04) : 542 - 547
  • [10] Sentinel Node Biopsy to Evaluate the Role of Tumour Regression in Thin Melanomas
    De Gaudio, C.
    Cecchi, R.
    Ciliberti, V.
    Buralli, L.
    Tarchi, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S232 - S233