Marginal adaptation of fixed prosthodontics: A new in vitro 360-degree external examination procedure

被引:0
|
作者
Gassino, G [1 ]
Monfrin, SB [1 ]
Scanu, M [1 ]
Spina, G [1 ]
Preti, G [1 ]
机构
[1] Univ Turin, Dipartimento FisioPatol Clin, Sez Riabilitaz Orale & Protesi Maxillo Faciale, Cattedra Prot Dent, I-10126 Turin, Italy
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the marginal fit of experimental and custom-made fixed prosthetic restorations through a new 360-degree external examination. The minimum number of gap measurements required to produce relevant results for gap analysis was also investigated. Materials and Methods: The marginal fit of six experimental and eight custom-made crowns was observed microscopically by means of a mechanical device, and software was employed to measure the gap. Two crowns, chosen from among the 14 previously evaluated, were reanalyzed to determine the minimum number of gap measurements required to produce significant results for gap analysis. Results: The precision obtained with the custom-made crowns differed from that of the experimental specimens. The minimum number of measurements required to produce a sample mean value within 5 pm of the mean, calculated over 360 measurements, taking standard error of the means less than or equal to 4 mum, was 18 for experimental and 90 for custom-made crowns, for both equidistant measurement spacing and randomly selected points. Conclusion: Differences in fit between experimental specimens and custom-made ones showed that experimental results might not always be obtained in clinical practice. Within the limitations of the protocol of this study, the minimum number of measurements required to ensure relevant results for gap analysis was 18 for experimental and 90 for custom-made crowns.
引用
收藏
页码:218 / 223
页数:6
相关论文
共 50 条
  • [1] 360-Degree canalith repositioning procedure for the horizontal canal
    Tirelli, G
    Russolo, M
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (05) : 740 - 746
  • [2] The Key to 360-Degree Video Advertising: An Examination of the Degree of Narrative Structure
    Feng, Yang
    Xie, Quan
    Lou, Chen
    JOURNAL OF ADVERTISING, 2019, 48 (02) : 137 - 152
  • [3] A New Adaptation Approach for Viewport-adaptive 360-degree Video Streaming
    Nguyen, Duc V.
    Tran, Huyen T. T.
    Pham, Anh T.
    Truong Cong Thang
    2017 IEEE INTERNATIONAL SYMPOSIUM ON MULTIMEDIA (ISM), 2017, : 38 - 44
  • [4] Scapholunate Ligament Internal Brace 360-Degree Tenodesis (SLITT) Procedure
    Kakar, Sanjeev
    Greene, Ryan M.
    JOURNAL OF WRIST SURGERY, 2018, 7 (04) : 336 - 340
  • [5] A client-based adaptation framework for 360-degree video streaming
    Nguyen, D. V.
    Tran, Huyen T. T.
    Truong Cong Thang
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2019, 59 : 231 - 243
  • [6] New method of surgical repair for 360-degree cyclodialysis
    Yuen, NSY
    Hui, SP
    Woo, DCF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (01): : 13 - 17
  • [7] New sewer scanner provides 360-degree image
    不详
    CIVIL ENGINEERING, 1999, 69 (11): : 30 - 30
  • [8] TBRA: Tiling and Bitrate Adaptation for Mobile 360-Degree Video Streaming
    Zhang, Lei
    Suo, Yanyan
    Wu, Ximing
    Wang, Feng
    Chen, Yuchi
    Cui, Laizhong
    Liu, Jiangchuan
    Ming, Zhong
    PROCEEDINGS OF THE 29TH ACM INTERNATIONAL CONFERENCE ON MULTIMEDIA, MM 2021, 2021, : 4007 - 4015
  • [9] Development of a new 360-degree surface topography application
    Michalik, R.
    Siebers, H.
    Eschweiler, J.
    Quack, V
    Gatz, M.
    Dirrichs, T.
    Betsch, M.
    GAIT & POSTURE, 2019, 73 : 39 - 44
  • [10] Reinforcement Learning Based Rate Adaptation for 360-Degree Video Streaming
    Jiang, Zhiqian
    Zhang, Xu
    Xu, Yiling
    Ma, Zhan
    Sun, Jun
    Zhang, Yunfei
    IEEE TRANSACTIONS ON BROADCASTING, 2021, 67 (02) : 409 - 423