Application of Mid-Infrared Spectroscopy for Determination of Insoluble Dietary Fiber Content in Moso Bamboo Shoot

被引:4
|
作者
Yu, Xinjie [2 ,3 ]
Liu, Kangsheng [3 ]
Yu, Xin [2 ]
Wu, Di [1 ]
He, Yong [1 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310029, Zhejiang, Peoples R China
[2] Zhejiang Univ, Ningbo Inst Technol, Ningbo 315100, Zhejiang, Peoples R China
[3] Zhejiang Univ, Dept Mat, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Moso Bamboo Shoot; Insoluble Dietary Fiber; Mid-Infrared Spectroscopy; Partial Least Squares; NEAR-INFRARED SPECTROSCOPY; LEAST-SQUARES REGRESSION; MILK POWDER; NONDESTRUCTIVE MEASUREMENT; EUCALYPTUS-GLOBULUS; MIR SPECTROSCOPY; SOLID WOOD; CELLULOSE; LIGNIN; FRUIT;
D O I
10.1166/sl.2012.1825
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mid-infrared (MIR) spectroscopy was used to measure insoluble dietary fiber content (IDFC) in moso bamboo shoot. A total of 140 moso bamboo shoot samples with various IDFC levels between 0.46% and 0.213% were separated into two groups, as calibration and validation sets. Reference IDFC in moso bamboo shoot was verified using AOAC 991.43 method. MIR absorbance spectra from 400 cm(-1) to 4000 cm(-1) were collected using the calibration and validation sets. Partial least squares (PLS) analysis was performed on the calibration set, and calibration models were developed using original MIR absorbance spectra and its Savitzky-Golay first derivative spectra. Standard error of calibration (SEC) and coefficient of multiple determinations (R-2) of the calibration models were calculated to select the best model. Savitzky-Golay first derivative spectra calibration model was found to be the best, with the lowest SEC of 0.007 and highest R-2 of 0.968. This calibration model was then used to predict IDFC in moso bamboo shoots from the validation set. Predicted and reference IDFC values were compared. Relative percent deviation (RPD) and standard error of prediction (SEP) were calculated to validate the goodness of fit of the model. The Savitzky-Golay first derivative spectra calibration model gave an RPD of 3.710 with a corresponding SEP of 0.011, which indicated that MIR spectroscopy technique coupled with PLS was a rapid and accurate way for determination of IDFC in moso bamboo shoot.
引用
收藏
页码:600 / 607
页数:8
相关论文
共 50 条
  • [1] Infrared Spectra Modeling of Insoluble Dietary Fiber Content in Moso Bamboo Shoot Based on Autoencoder Network Manifold Learning
    Yu Xin-jie
    Yin Jiao-jiao
    Yu Xin
    He Yong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (06) : 1512 - 1516
  • [2] Determination of the Recovered-Fiber Content in Paperboard Samples by Applying Mid-Infrared Spectroscopy
    Riba, Jordi-Roger
    Canals, Trini
    Cantero, Rosa
    APPLIED SPECTROSCOPY, 2015, 69 (04) : 442 - 450
  • [3] Research on Determination of Nitrogen Content in Petroleum Using Mid-infrared Spectroscopy
    Li Jingyan
    Chu Xiaoli
    Tian Songbai
    Lu Wanzhen (SINOPEC Research Institute of Petroleum Processing
    ChinaPetroleumProcessing&PetrochemicalTechnology, 2011, 13 (04) : 1 - 7
  • [4] Research on Determination of Nitrogen Content in Petroleum Using Mid-infrared Spectroscopy
    Li Jingyan
    Chu Xiaoli
    Tian Songbai
    Lu Wanzhen
    CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2011, 13 (04) : 1 - 7
  • [5] Application of mid-infrared photoacoustic spectroscopy in monitoring carbonate content in soils
    Du Changwen
    Ma Zhaoyang
    Zhou Jianmin
    Goyne, Keith W.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1167 - 1175
  • [6] Determination of Hemicellulose, Cellulose and Lignin in Moso Bamboo by Near Infrared Spectroscopy
    Xiaoli Li
    Chanjun Sun
    Binxiong Zhou
    Yong He
    Scientific Reports, 5
  • [7] Determination of Hemicellulose, Cellulose and Lignin in Moso Bamboo by Near Infrared Spectroscopy
    Li, Xiaoli
    Sun, Chanjun
    Zhou, Binxiong
    He, Yong
    SCIENTIFIC REPORTS, 2015, 5
  • [8] Determination of lignin in tobacco by mid-infrared spectroscopy
    Kong, Haohui, 1600, Editorial Office of Tobacco Science and Technology
  • [9] Application of mid-infrared fiber laser sources
    Geng, Jihong
    Jiang, Shibin
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [10] Application of supercontinuum radiation for mid-infrared spectroscopy
    Kilgus, Jakob
    Mueller, Petra
    Moselund, Peter M.
    Brandstetter, Markus
    OPTICAL SENSING AND DETECTION IV, 2016, 9899