Structural health monitoring of continuous prestressed concrete bridges using ambient thermal responses

被引:53
|
作者
Kulprapha, Nonthachart [1 ]
Warnitchai, Pennung [1 ]
机构
[1] Asian Inst Technol, Sch Engn & Technol, Klongluang 12120, Pathumthani, Thailand
关键词
Structural health monitoring (SHM); Damage detection; Ambient thermal responses; Continuous prestressed concrete bridges; SENSORS;
D O I
10.1016/j.engstruct.2012.02.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The feasibility to monitor the structural health of multi-span prestressed concrete bridges by using their ambient thermal loads and responses is investigated. An 8-m-long, 2-span continuous concrete bridge is designed and constructed to represent typical full-scale bridges. The bridge is equipped with various sensors to continuously monitor temperatures, strains, deflections, and support reaction forces, and is exposed directly to sunlight, rain, wind, and dewfall in order to attain a realistic ambient thermal loading condition. Five states of distributed flexural damage, ranging from slight to severe, are created in the experimental bridge by applying two overloaded concentrated forces. At every damage state as well as the initial undamaged state, the thermal loads and responses of the bridge are continuously monitored for several days, and these responses are compared with those predicted by a newly developed analytical model. This model takes into account of nonlinear temperature distribution in bridge cross sections, presence of prestressing forces, support flexibility, and initial crookness of bridge span. An excellent agreement between model predictions and monitored responses are obtained for the initial undamaged state. The monitored responses in five damage states are again compared with the model predictions of the undamaged state. As expected, the discrepancy between them increases with increasing of damage level. A scheme to account for distributed flexural damage is then developed for the analytical model. By using this scheme, it is possible to tune the model predictions to match with the monitored responses. Through this model tuning process, approximate damage distribution pattern and damage severity along the entire bridge length can be identified. The study clearly demonstrates that an effective structural health monitoring system based on ambient thermal loads and responses can be successfully developed for multi-span prestressed concrete bridges. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:20 / 38
页数:19
相关论文
共 50 条
  • [1] Health monitoring of prestressed concrete bridges using artificial neural networks
    Mo, Y. L.
    Jeng, C. H.
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2006, : 1247 - 1254
  • [2] Structural Health Monitoring of FRP-Reinforced Concrete Bridges Using Vibration Responses
    Kiani, Nafiseh
    Abedin, Mohammad
    Steputat, Christian C.
    Mehrabi, Armin B.
    Nanni, Antonio
    EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING (EWSHM 2022), VOL 1, 2023, 253 : 735 - 744
  • [3] Structural health monitoring of concrete bridges
    Bergmeister, K
    Santa, U
    INTERFEROMETRY IN SPECKLE LIGHT: THEORY AND APPLICATIONS, 2000, : 633 - 640
  • [4] Continuous CFRP Prestressed Concrete Bridges
    Concr. Int., 10 (42-47):
  • [5] Prestressed Continuous Bridge Evaluation using Structural Health Monitoring System
    Ban, Woo Hyun
    Hu, Jong Wan
    Kaloop, Mosbeh R.
    2018 5TH INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS, MECHANICS AND STRUCTURAL ENGINEERING (AMMSE), 2019, 473
  • [6] Condition transfer between prestressed bridges using structural state translation for structural health monitoring
    Furkan Luleci
    F. Necati Catbas
    AI in Civil Engineering, 2 (1):
  • [7] Reliability evaluation of reinforced concrete bridges using structural health monitoring
    Colombo, A. B.
    Bittencourt, T. N.
    Frangopol, D. M.
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 228 - 228
  • [8] CABLE DESIGN FOR CONTINUOUS PRESTRESSED CONCRETE BRIDGES
    BURGOYNE, CJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1988, 85 : 161 - 184
  • [9] Continuous monitoring of in-service performance of prestressed concrete continuous bridges with two strengthening measures
    Song, Xiaodong
    Gong, Xiaoyu
    Li, Guangqi
    Xiong, Wen
    Cai, C. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 321
  • [10] Analysis of thermal stress for prestressed concrete continuous box-girder bridges
    Lanzhou Jiaotong University, Lanzhou 730070, China
    不详