Flow-injection assay of catalase activity

被引:2
|
作者
Ukeda, H [1 ]
Adachi, Y [1 ]
Sawamura, M [1 ]
机构
[1] Kochi Univ, Fac Agr, Dept Bioresource Sci, Nankoku, Kochi 7838502, Japan
关键词
D O I
10.2116/analsci.20.471
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel flow-injection assay (FIA) system with a double line for catalase activity was constructed in which an oxidase is immobilized and the substrate is continuously pumped to reduce the dissolved oxygen and to generate a given level of hydrogen peroxide. The catalase in a sample decomposed the hydrogen peroxide, and thus the increase in dissolved oxygen dependent on the activity was amperometrically monitored using a Clark-type oxygen electrode. Among the examined several oxidases, uricase was most suitable for the continuous formation of hydrogen peroxide from a consideration of the stability and the conversion efficiency. Under the optimum conditions, a linear calibration curve was obtained in the range from 21 to 210 units/mg and the reproducibility (CV) was better than 2% by 35 successive determinations of 210 units/ml catalase preparation. The sampling frequency was about 15 samples/h. The present FIA system was applicable to monitor the inactivation of catalase by glycation.
引用
收藏
页码:471 / 474
页数:4
相关论文
共 50 条
  • [1] Flow-Injection Assay of Catalase Activity
    Hiroyuki Ukeda
    Yukiko Adachi
    Masayoshi Sawamura
    Analytical Sciences, 2004, 20 : 471 - 474
  • [2] Determination of catalase activity in soils by flow-injection chemiluminescence methods.
    Liu, WP
    Yang, WC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U133 - U133
  • [3] ASSAY OF BETA-GALACTOSIDASE ACTIVITY BY FLOW-INJECTION ANALYSIS (FIA)
    CAIRO, J
    VIDAL, M
    VILLAVERDE, A
    VALERO, F
    LAFUENTE, FJ
    SOLA, C
    BIOTECHNOLOGY TECHNIQUES, 1991, 5 (05) : 389 - 392
  • [4] AUTOMATED FLOW-INJECTION METHOD FOR THE ASSAY OF XANTHINE-OXIDASE ACTIVITY
    MASOOM, M
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1989, 11 (03): : 210 - 213
  • [5] FLOW-INJECTION AMPEROMETRIC SYSTEM FOR IMMUNOENZYME ASSAY
    IVNITSKII, DM
    SITDYKOV, RA
    DZANTIEV, BB
    ZHERDEV, AV
    EGOROV, AM
    DOLIDZE, SA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1989, 44 (01): : 127 - 131
  • [6] Flow-injection chemiluminometric assay of superoxide dismutase
    Ukeda, H
    Sarker, AK
    Kawana, D
    Sawamura, M
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 137 - 142
  • [7] Pyrophosphate as substrate for alkaline phosphatase activity: A convenient flow-injection chemiluminescence assay
    Zhang, Qingfeng
    Zhang, Cuiyun
    Yang, Meiding
    Yu, Donghong
    Yu, Cong
    LUMINESCENCE, 2017, 32 (07) : 1150 - 1156
  • [8] Micelle enhanced spectrofluorimetric assay for laccase activity by a flow-injection stopped-flow technique
    Huang, HP
    Cai, RX
    Du, YM
    Lin, ZX
    Zeng, Y
    ANALYTICA CHIMICA ACTA, 1995, 318 (01) : 63 - 69
  • [9] MULTISTEP DETERMINATION OF ENZYME-ACTIVITY BY FLOW-INJECTION AND SEQUENTIAL INJECTION-ANALYSIS - ASSAY OF AMYLOGLUCOSIDASE
    HANSEN, EH
    WILLUMSEN, B
    WINTHER, SK
    DRABOL, H
    TALANTA, 1994, 41 (11) : 1881 - 1893
  • [10] CHEMILUMINESCENT ASSAY FOR GLYCEROL IN WINE USING FLOW-INJECTION
    PUCHADES, R
    LEMIEUX, L
    SIMARD, RE
    JOURNAL OF FOOD SCIENCE, 1991, 56 (04) : 1097 - 1100