Fracture Model for PT Flat Plate Connections under Seismic Loading

被引:0
|
作者
Moon, Ki-Hoon [1 ]
Hwang-Bo, Jin [1 ]
Han, Sang-Whan [1 ]
机构
[1] Hanyang Univ, Seoul 133791, South Korea
来源
关键词
PT flat plate; connection; nonlinear behavior; pushover;
D O I
10.4028/www.scientific.net/KEM.385-387.709
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Post-tensioned (PT) flat plate frames are commonly used to support gravity load in connections in high seismic regions. But test results of many studies indicated that PT flat plate connections were possessed of later-resisting capacity for lateral load though this capacity is not enough to be used by itself in high seismic regions. So this study evaluated the cyclic behavior of PT flat plate connections and developed an analytical model for predicting nonlinear behavior of those to estimate the seismic performance of PT flat plate frames accurately. For this purpose, the test results of static pushover test and shaking table test of 2 story PT flat plate frame were used to evaluate the characters of failure mode for PT flat plate connections and to compare with analysis results. The test results indicated two failure modes which are classified the shear failure mode or the moment failure mode as for shear strength of PT connections to resist lateral loads acted on the specimens. So the analytical model was designed to consider these failure modes of PT connections and the results of comparing with test results predict the nonlinear behavior of PT connections.
引用
收藏
页码:709 / +
页数:2
相关论文
共 50 条
  • [1] SEISMIC RESISTANCE OF FLAT PLATE CORNER CONNECTIONS.
    de Paiva, H.A.R.
    Zaghlool, E.R.F.
    Engineering Journal (Montreal), 1973, 56 (09):
  • [2] Fatigue and fracture behavior of moment frame connections under seismic loading (Northridge earthquake)
    Barsom, JM
    FATIGUE AND FRACTURE MECHANICS: 33RD VOLUME, 2003, 1417 : 57 - 72
  • [3] Seismic capacity of reinforced concrete interior flat plate connections
    Youssef, Maged A.
    Chowdhury, Abu Obayed
    Meshaly, Mohamed E.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (03) : 827 - 840
  • [4] Seismic capacity of reinforced concrete interior flat plate connections
    Maged A. Youssef
    Abu Obayed Chowdhury
    Mohamed E. Meshaly
    Bulletin of Earthquake Engineering, 2015, 13 : 827 - 840
  • [5] Equivalent frame analysis of flat plate buildings for seismic loading
    Luo, Y.H.
    Durrani, A.J.
    Conte, J.P.
    Journal of structural engineering New York, N.Y., 1994, 120 (07): : 2137 - 2154
  • [6] The behaviour of hollow section connections under seismic loading
    Hall, SK
    TUBULAR STRUCTURES X, 2003, : 609 - 619
  • [7] Gusset plate connections under monotonic and cyclic loading
    Walbridge, SS
    Grondin, GY
    Cheng, JJR
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2005, 32 (05) : 981 - 995
  • [8] 'Heavy' moment end-plate connections subjected to seismic loading
    Sumner, EA
    Mays, TW
    Murray, TM
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 735 - 740
  • [9] Rational Use of High-Strength Concrete in Flat Slab-Column Connections under Seismic Loading
    Inacio, Micael
    Isufi, Brisid
    Lapi, Massimo
    Ramos, Antonio Pinho
    ACI STRUCTURAL JOURNAL, 2020, 117 (06) : 297 - 310
  • [10] Advances in the structural performance of reinforced concrete flat plate-column connections under gravity and seismic loads
    Abathar M. Al-Yaseri
    Laith Kh. Al-Hadithy
    Journal of Building Pathology and Rehabilitation, 2025, 10 (1)