Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration

被引:24
|
作者
Ellis, R
ToksvigLarsen, S
Marcacci, M
Caramella, D
Fadda, M
机构
[1] UNIV LUND HOSP,DEPT ORTHOPAED SURG,S-22185 LUND,SWEDEN
[2] RIZZOLI ORTHOPAED INST,BIOMECH LAB,BOLOGNA,ITALY
关键词
registration; validation; computed tomography; computer-assisted surgery;
D O I
10.1097/00004424-199610000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Accurate registration of computed tomography (CI) images to the patient is crucial for computer-assisted surgery, Markers used in roentgen stereo-grammetric analysis (RSA) can be located in a CT scan using a novel approach and also can be located physically, Roentgen stereo-grammetric analysis data act as ''ground truth'' for the three-dimensional marker locations. METHODS. Two foam-bone phantoms were marked, The markers were scanned seven times with RSA, three times with axial CT, and contacted four times with a coordinate measuring arm, Root-mean-square (RMS) errors were derived for the registrations. RESULTS. Computed tomography and RSA data register to 0.15 mm RMS error, Computed tomography and arm data register to 0.25 mm, The markers are biocompatible, and the coordinate measuring arm is usable in an operating room. CONCLUSIONS. Typical in vitro registration errors are approximately 2 mm, The authors have developed a marker that provides superior registration, and a procedure that can be used for in vivo studies.
引用
收藏
页码:658 / 667
页数:10
相关论文
共 50 条
  • [1] A biocompatible fiducial marker for evaluating the accuracy of CT image registration
    Ellis, RE
    ToksvigLarsen, S
    Marcacci, M
    Caramella, D
    Fadda, M
    [J]. CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 693 - 698
  • [2] Accuracy of Fiducial Marker Based Multimodal Image Registration in Image Guided Surgery
    Zhang Hongwei
    Wang Guangzhi
    Ding Hui
    [J]. 6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1538 - +
  • [3] High accuracy, fiducial marker-based image registration of correlative microscopy images
    Mohammadian, Sajjad
    Fokkema, Jantina
    Agronskaia, Alexandra V.
    Liv, Nalan
    de Heus, Cecilia
    van Donselaar, Elly
    Blab, Gerhard A.
    Klumperman, Judith
    Gerritsen, Hans C.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [4] High accuracy, fiducial marker-based image registration of correlative microscopy images
    Sajjad Mohammadian
    Jantina Fokkema
    Alexandra V. Agronskaia
    Nalan Liv
    Cecilia de Heus
    Elly van Donselaar
    Gerhard A. Blab
    Judith Klumperman
    Hans C. Gerritsen
    [J]. Scientific Reports, 9
  • [5] Alumina as a Computed Tomography Soft Material and Tissue Fiducial Marker
    Stephens, S. E.
    Ingels, N. B.
    Wenk, J. F.
    Jensen, M. O.
    [J]. EXPERIMENTAL MECHANICS, 2022, 62 (05) : 879 - 884
  • [6] Alumina as a Computed Tomography Soft Material and Tissue Fiducial Marker
    S. E. Stephens
    N. B. Ingels
    J. F. Wenk
    M. O. Jensen
    [J]. Experimental Mechanics, 2022, 62 : 879 - 884
  • [7] A study on the image registration accuracy of intrafraction cone beam computed tomography images
    Arumugam, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S566 - S566
  • [8] Accuracy in automatic image registration between MV cone beam computed tomography and planning kV computed tomography in image guided radiotherapy
    Kanakavelu, Nithya
    Samuel, E. James Jebaseelan
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (05) : 487 - 494
  • [9] Comparison of Dental Surface Image Registration and Fiducial Marker Registration: An In Vivo Accuracy Study of Static Computer-Assisted Implant Surgery
    Han, Yen-Ting
    Lin, Wei-Chun
    Fan, Fang-Yu
    Chen, Chih-Long
    Lin, Chia-Cheng
    Cheng, Hsin-Chung
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [10] The in-vitro accuracy of fiducial marker-based versus markerless registration of an intraoral scan with a cone-beam computed tomography scan in the presence of restoration artifact
    Biun, John
    Dudhia, Raahib
    Arora, Himanshu
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (11) : 1257 - 1266