The effect of catheter use on vein grafting of a peripheral nerve defect: an experimental study

被引:2
|
作者
Bayraktar, Alper Mehmet [1 ]
Ozbek, Serhat [2 ]
Ozcan, Mesut [2 ]
Noyan, Behzat [3 ]
Cavusoglu, Ilkin [4 ]
机构
[1] Cekirge Devlet Hastanesi, Dept Plast & Reconstruct Surg, Bursa, Turkey
[2] Uludag Univ, Fac Med, Dept Plast & Reconstruct Surg, Bursa, Turkey
[3] Uludag Univ, Fac Med, Dept Physiol, Bursa, Turkey
[4] Uludag Univ, Fac Med, Dept Histol, Bursa, Turkey
关键词
Peripheral nerve injury; nerve defect; vein graft; SCIATIC FUNCTION INDEX; TO-SIDE NEURORRHAPHY; FUNCTIONAL-EVALUATION; MUSCLE GRAFTS; REGENERATION; REPAIR; RAT; CONDUIT; INTERPOSITION; TRANSECTION;
D O I
10.5505/tjtes.2012.59932
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND Since vein grafts have been used in the repair of nerve defects, studies regarding this procedure have accumulated, and after coming into clinical use, it was noticed that there is a problem of collapse in the vein graft. METHODS Forty Sprague-Dawley rats were used, divided into five groups. No surgical intervention was performed in the first group. The defect was created in the sciatic nerve in Group 2 and left unrepaired. In Group 3, the defect was repaired with a nerve graft. In Group 4, the defect was repaired with a vein graft, while in Group 5, the repair was performed using a vein graft with an inserted catheter. In order to evaluate functional recovery and nerve regeneration, walking track analysis, electrophysiologic and histomorphometric analyses were done at the end of the 12th week. RESULTS Although there were no functional differences between Groups 5 and 4, comparisons regarding nerve conduction velocity demonstrated that the results obtained in Group 5 were better than those in Group 4. When the number of axons on the distal part of the sciatic nerve and mid-segment of the repaired area was taken into account, no significant difference was found between Groups 3 and 5, whereas there was a significant difference between Groups 4 and 5. CONCLUSION In our study, it was experimentally shown that the problem of collapse of a vein graft occurring after its use in the reconstruction of a nerve defect can be overcome by placing a catheter into the vein graft. Consequently, this method may eliminate the need for the use of a nerve graft in selected cases.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 50 条
  • [1] USE OF POLYTETRAFLUORINATED ETHYLENE COMPOUND IN PERIPHERAL-NERVE GRAFTING - AN EXPERIMENTAL-STUDY
    RICE, DH
    BURSTEIN, FD
    NEWMAN, A
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1985, 111 (04) : 259 - 261
  • [2] THE USE OF AUTOGENOUS VEIN FOR NERVE GRAFTING
    RICE, DH
    BERSTEIN, FD
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1984, 92 (04) : 410 - 412
  • [3] Nerve grafting for peripheral nerve injuries with extended defect sizes
    Kornfeld, Tim
    Vogt, Peter M.
    Radtke, Christine
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 2019, 169 (9-10) : 240 - 251
  • [4] Use of acellular dermal matrix in peripheral nerve reconstruction: an experimental study on rat sciatic nerve defect
    Ceran, Fatih
    Pilanci, Ozgur
    Ozel, Asuman
    Ilbay, Gul
    Karabacak, Rukiye
    Kanter, Mehmet
    Ilbay, Konuralp
    Kuvat, Samet Vasfi
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2023, 57 (1-6) : 445 - 452
  • [5] AN EXPERIMENTAL-STUDY OF THE USE OF DEGENERATE NERVE GRAFTING COMPARED WITH FRESH NERVE GRAFTING
    CAPO, SR
    FERNANDEZ, CN
    OBIOLS, LM
    SOLER, RR
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1982, 68 (05): : 291 - 297
  • [6] Use of an intact sensory nerve to bridge a motor nerve defect:: an experimental study
    Tirelioglu, S
    Özbek, S
    Özcan, M
    Kurt, MA
    Noyan, B
    JOURNAL OF NEUROSURGERY, 2006, 104 (05) : 804 - 809
  • [7] Effect of oblique nerve grafting on peripheral nerve regeneration in rats
    Kotulska, Katarzyna
    Marcol, Wieslaw
    Larysz-Brysz, Magdalena
    Tendera, Zofia
    Malinowska-Kolodziej, Izabela
    Slusarczyk, Wojciech
    Jedrzejowska-Szypulka, Halina
    Lewin-Kowalik, Joanna
    MICROSURGERY, 2006, 26 (08) : 579 - 584
  • [8] Use of a natural latex membrane for nerve grafting: an experimental study.
    Muniz Ganga, Marcos Vinicius
    Sassoli Fazan, Valeria Paula
    Marques Junior, Wilson
    Lopes, Luiza da Silva
    FASEB JOURNAL, 2012, 26
  • [9] The experimental study of absorbable chitin conduit for bridging peripheral nerve defect with nerve fasciculu in rats
    Zhang, Peixun
    Xue, Feng
    Kou, Yuhui
    Fu, Zhongguo
    Zhang, Dianying
    Zhang, Hongbo
    Jiang, Baoguo
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2008, 36 (04): : 360 - 371
  • [10] Experimental study of biodegradable polymer conduit with collagen sponge for peripheral nerve defect
    Nakatsuka, H
    Takamatsu, K
    Koshimune, M
    Kazuki, K
    Takaoka, K
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2005, 10 : 65 - 65