摘要
Dynamic contact angle measurement was performed on primary packaging containers made from non-treated glass and with silicone surface coating. The goal of this study was to quantify the hydrophobicity of glass surfaces. As a measure of the interaction, the contact angle of the glass surface with a liquid was measured by force tensiometry (wetted length method). This method can measure the contact angle of liquids on a curved surface. The reference measurement was the contact angle of water for injection (WFI) on non-treated and impregnated glass surfaces, then the contact angles between three aqueous protein product solutions and non-treated and impregnated glass cartridges were measured by the same procedure. The contact angle of water and the protein solutions with the non-treated glass cartridges was found to be 0 degrees, which is an expected value for a clean glass surface. The advancing contact angle of WFI as well as the investigated protein solutions with the siliconized glass surfaces was found to be 60-95 degrees. The non-treated cartridges were coated with polydimethylsiloxane and siliconized by a burning-in process. The advancing contact angles measured on siliconized glass surfaces were higher than those measured on non-treated glass surfaces, i.e., on siliconized glass surfaces poor wetting was observed for water and all three aqueous protein solutions. The siliconized glass surfaces are more hydrophobic than non-treated glass. The results show that the applied force tensiometry method is capable of detecting differences in wetting behaviour on strongly curved glass surfaces.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 4 条
  • [1] Drop shape visualization and contact angle measurement on curved surfaces
    Guilizzoni, Manfredo
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2011, 364 (01) : 230 - 236
  • [2] Measurement of adhesion strengths between various milk products on glass surfaces using contact angle measurement and atomic force microscopy
    Handojo, Aldo
    Zhai, Yumei
    Frankel, Gerald
    Pascall, Melvin A.
    JOURNAL OF FOOD ENGINEERING, 2009, 92 (03) : 305 - 311
  • [3] Contact Angle Measurement on Curved Wetting Surfaces in Multiphase Lattice Boltzmann Method
    Liu, Yangsha
    Yao, Yichen
    Li, Quanying
    Zhong, Xingguo
    He, Bing
    Wen, Binghai
    LANGMUIR, 2023, 39 (08) : 2974 - 2984
  • [4] A correlative study of the measurement of protein adsorption to steel, glass, polypropylene, and silicone surfaces using ToF-SIMS and dynamic contact angle analyses
    Davies, J
    Nunnerley, CS
    Paul, AJ
    COLLOIDS AND SURFACES B-BIOINTERFACES, 1996, 6 (03) : 181 - 190