Occlusal comparison of hand-articulation versus digital articulation in orthognathic surgery

被引:1
|
作者
Moore, Blake K. [1 ]
Deane, Stuart
Huang, Weber [1 ]
Kim, James [1 ]
Parthasarathi, Krishnan
机构
[1] Westmead Hosp, Sydney, NSW, Australia
来源
关键词
Orthognathic surgery; occlusal planning;
D O I
10.1016/j.bjoms.2021.07.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present study was to develop measurement methods to evaluate occlusal differences in digitally-articulated and handarticulated models in final occlusal planning for orthognathic surgery. A total of 10 (five class II and five class III) previously treated orthognathic cases were analysed by three oral and maxillofacial surgeon investigators, creating a total of thirty cases. Investigators used physical models to create a preferred hand-held final occlusion, which were then scanned and saved utilising a Trios 3?? scanner (3Shape). Models were digitally disarticulated and sent back to investigators after a period of at least a month for digital articulation. Novel measurements of dental roll, pitch, and translational differences were performed by an independent engineer using Materialise 3-Matic?? software. Statistical analysis was used to evaluate translational differences, the effect of deformity, and inter-investigator variation. A mean (SD) translational difference of 1.58 mm (1.14) mm was seen between the thirty digital and hard-articulated cases analysed. Minimal difference was seen in roll and pitch between hand articulation and digital articulation. A significant translational difference was seen in class III cases compared with class II (p = 0.0006) but not in roll or pitch. There was no significant difference seen between investigators related to translation (p = 0.18), roll (p = 0.09), or pitch (p = 0.17). Digital articulation yielded similar results to hand held in this pilot study. Using measurement techniques described in larger cohorts, its accuracy can be validated using currently available technology. Crown Copyright ?? 2021 Published by Elsevier Ltd on behalf of The British Association of Oral and Maxillofacial Surgeons. All rights reserved.
引用
下载
收藏
页码:443 / 447
页数:5
相关论文
共 38 条
  • [1] Reproducibility and reliability of digital occlusal planning for orthognathic surgery
    Almadi, D.
    Benington, P.
    Ju, X.
    Ayoub, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (10) : 1074 - 1080
  • [2] Clinical feasibility evaluation of digital dental articulation for three-piece maxillary orthognathic surgery: a proof-of-concept study
    Frick, C. J.
    Deng, H. H.
    English, J. D.
    Jacob, H. B.
    Kuang, T.
    Grissom, M. K.
    Kim, D.
    Gateno, J.
    Xia, J. J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 51 (08) : 1043 - 1049
  • [3] Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation
    Porter, Jason L.
    Carrico, Caroline K.
    Lindauer, Steven J.
    Tufekci, Eser
    JOURNAL OF ORTHODONTICS, 2018, 45 (04) : 275 - 282
  • [4] Comparison of Occlusal Digital Analysis Using T-Scan in Orthognathic Surgery with Only Conventional Orthodontic Patients
    Manikandhan, R.
    Manikandan, S.
    Ponvel, Keerthana
    Parameswaran, Ratna
    Shankar, Sathya
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (02): : 397 - 409
  • [5] Comparison of Occlusal Digital Analysis Using T-Scan in Orthognathic Surgery with Only Conventional Orthodontic Patients
    R. Manikandhan
    S. Manikandan
    Keerthana Ponvel
    Ratna Parameswaran
    Sathya Shankar
    Journal of Maxillofacial and Oral Surgery, 2023, 22 : 397 - 409
  • [6] Clinical Evaluation of Digital Dental Articulation for One-Piece Maxillary Surgery
    Wong, Sonny
    Deng, Han
    Gateno, Jaime
    Yuan, Peng
    Garrett, Fred A.
    Ellis, Randy K.
    English, Jeryl D.
    Jacob, Helder B.
    Kim, Daeseung
    Xia, James J.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (05) : 799 - 805
  • [7] The Effect of Bimaxillary Orthognathic Surgery on Nasalance, Articulation Errors, and Speech Intelligibility in Skeletal Class III Deformity Patients
    Ghaemi, Hamide
    Emrani, Erfan
    Labafchi, Ali
    Famili, Khashyar
    Hashemzadeh, Haleh
    Samieirad, Sahand
    WORLD JOURNAL OF PLASTIC SURGERY, 2021, 10 (01) : 8 - +
  • [8] Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models
    Sweeney, Sunya
    Smith, Derek K.
    Messersmith, Marion
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (02) : 245 - 252
  • [9] The role of the occlusal wafer in orthognathic surgery; A comparison of thick and thin intermediate osteotomy wafers
    Bamber, MA
    Harris, M
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1995, 23 (06) : 396 - 400
  • [10] Accuracy of a digital workflow for bimaxillary orthognathic surgery: comparison of planned and actual outcomes
    Lee, Ker Jia Cheryl
    Tan, Suat Li
    Tan, Danny Ben Poon
    Yong, Chee Weng
    Chew, Ming Tak
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (04) : 397 - 405