Temporal choroidal hump in the Swept-Source OCT choroidal thickness profile of a healthy population.

被引:0
|
作者
Ruiz-Medrano, Jorge [1 ]
Flores-Moreno, Ignacio [2 ]
Montero, Javier A. [3 ]
Ruiz-Moreno, Jose M. [2 ]
机构
[1] Hosp Univ Clin San Carlos, Madrid, Spain
[2] Univ Castilla La Mancha, Dept Ophthalmol, Albacete, Spain
[3] Pio del Rio Hortega Univ Hosp, Ophthalmol Unit, Valladolid, Spain
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
5287
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Macular choroidal thickness profile in healthy population measured by swept-source optical coherence tomography
    Moreno, J. M. Ruiz
    Ruiz-Medrano, J.
    Flores-Moreno, I.
    Pena-Garcia, P.
    Montero, J. A.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [2] Macular Choroidal Thickness Profile in a Healthy Population Measured by Swept-Source Optical Coherence Tomography
    Ruiz-Medrano, Jorge
    Flores-Moreno, Ignacio
    Pena-Garcia, Pablo
    Montero, Javier A.
    Duker, Jay S.
    Ruiz-Moreno, Jose E. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3532 - 3542
  • [3] Widefield Choroidal Thickness of Eyes with Central Serous Chorioretinopathy Examined by Swept-Source OCT
    Ishikura, Masaharu
    Muraoka, Yuki
    Nishigori, Naomi
    Takahashi, Ayako
    Miyake, Masahiro
    Ueda-Arakawa, Naoko
    Miyata, Manabu
    Ooto, Sotaro
    Tsujikawa, Akitaka
    OPHTHALMOLOGY RETINA, 2022, 6 (10): : 949 - 956
  • [4] Choroidal thickness and structural glaucoma parameters in glaucomatous, preperimetric glaucomatous, and healthy eyes using swept-source OCT
    Akil, Handan
    Al-Sheikh, Mayss
    Falavarjani, Khalil Ghasemi
    Francis, Brian
    Chopra, Vikas
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 548 - 554
  • [5] Swept-Source OCT Angiography Identifies Choroidal Neovascularization Arising From a Choroidal Nevus
    Namavari, Abed
    Zheng, Fang
    Motulsky, Elie H.
    Dias, Joao R. de Oliveira
    Gregori, Giovanni
    Rosenfeld, Philip J.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2018, 49 (05): : 360 - 363
  • [6] ASYMMETRY IN MACULAR CHOROIDAL THICKNESS PROFILE BETWEEN BOTH EYES IN A HEALTHY POPULATION MEASURED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Ruiz-Medrano, Jorge
    Flores-Moreno, Ignacio
    Pena-Garcia, Pablo
    Montero, Javier A.
    Duker, Jay S.
    Ruiz-Moreno, Jose M.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (10): : 2067 - 2073
  • [7] Interocular asymmetry in choroidal thickness in healthy Indian population using swept-source optical coherence tomography
    Bhayana, Amber Amar
    Kumawat, Devesh
    Kumar, Vinod
    Chandra, Mahesh
    Chandra, Parijat
    Sihota, Ramanjit
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1252 - +
  • [8] Topographic Variations of Choroidal Thickness in Healthy Eyes on Swept-Source Optical Coherence Tomography
    Touhami, Sara
    Philippakis, Elise
    Mrejen, Sarah
    Couturier, Aude
    Casteran, Celine
    Levent, Priscille
    Tadayoni, Ramin
    Gaudric, Alain
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (03)
  • [9] Attenuation correction assisted automatic segmentation for assessing choroidal thickness and vasculature with swept-source OCT
    Zhou, Hao
    Chu, Zhongdi
    Zhang, Qinqin
    Dai, Yining
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Wang, Ruikang K.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6067 - 6080
  • [10] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257