Lipid profiling of FPLC-separated lipoprotein fractions by electrospray ionization tandem mass spectrometry

被引:286
|
作者
Wiesner, Philipp [1 ]
Leidl, Katharina [1 ]
Boettcher, Alfred [1 ]
Schmitz, Gerd [1 ]
Liebisch, Gerhard [1 ]
机构
[1] Univ Regensburg, Inst Clin Chem & Lab Med, D-8400 Regensburg, Germany
基金
芬兰科学院;
关键词
lipid species; lipoprotein fractionation; glycerophospholipids; sphingolipids; cholesterol; VLDL; LDL; HDL; fast performance liquid chromatography; HIGH-DENSITY-LIPOPROTEINS; HIGH-THROUGHPUT QUANTIFICATION; LECITHIN-CHOLESTEROL ACYLTRANSFERASE; CELLULAR FREE-CHOLESTEROL; HUMAN-PLASMA-LIPOPROTEINS; HUMAN SERUM-LIPOPROTEINS; CORONARY-ARTERY-DISEASE; ATHEROGENIC LIPOPROTEINS; QUANTITATIVE-ANALYSIS; TANGIER-DISEASE;
D O I
10.1194/jlr.D800028-JLR200
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glycerophospholipid and sphingolipid species and their bioactive metabolites are important regulators of lipoprotein and cell function. The aim of the study was to develop a method for lipid species profiling of separated lipoprotein classes. Human serum lipoproteins VLDL, LDL, and HDL of 21 healthy fasting blood donors were separated by fast performance liquid chromatography (FPLC) from 50 mu l serum. Subsequently, phosphatidylcholine (PC), lysophosphatidylcholine, sphingomyelin (SM), ceramide (CER), phosphatidylethanolamine (PE), PE-based plasmalogen (PE-pl), cholesterol, and cholesteryl ester (CE) content of the separated lipoproteins was quantified by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Analysis of FPLC fractions with PAGE demonstrated that albumin partially coelutes with HDL fractions. However, analysis of an HDL deficient serum (Tangier disease) showed that only lysophosphatidylcholine, but none of the other lipids analyzed, exhibited a significant coelution with the albumin containing fractions. Approximately 60% of lipoprotein CER were found in LDL fractions and 60% of PC, PE, and plasmalogens in HDL fractions. VLDL, LDL, and HDL displayed characteristic lipid class and species pattern. The developed method provides a detailed lipid class and species composition of lipoprotein fractions and may serve as a valuable tool to identify alterations of lipoprotein lipid species profiles in disease with a reasonable experimental effort.-Wiesner, P., K. Leidl, A. Boettcher, G. Schmitz, and G. Liebisch. Lipid profiling of FPLC-separated lipoprotein fractions by electrospray ionization tandem mass spectrometry. J. Lipid Res. 2009. 50: 574-585.
引用
收藏
页码:574 / 585
页数:12
相关论文
共 50 条
  • [1] Sphingolipid profiling of human plasma and FPLC-separated lipoprotein fractions by hydrophilic interaction chromatography tandem mass spectrometry
    Scherer, Max
    Boettcher, Alfred
    Schmitz, Gerd
    Liebisch, Gerhard
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (02): : 68 - 75
  • [2] Sphingolipid profiling in plasma and FPLC-separated lipoprotein fractions by LC-MS/MS
    Scherer, Max
    Schmitz, Gerd
    Liebisch, Gerhard
    CHEMISTRY AND PHYSICS OF LIPIDS, 2010, 163 : S54 - S54
  • [3] Lipid profiling of lipoproteins by electrospray ionization tandem mass spectrometry
    Scherer, Max
    Boettcher, Alfred
    Liebisch, Gerhard
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (11): : 918 - 924
  • [4] Lipid Profiling by Electrospray Ionization Tandem Mass Spectrometry and the Identification of Lipid Phosphorylation by Kinases in Potato Stolons
    Cenzano, Ana M.
    Cantoro, Renata
    Teresa Hernandez-Sotomayor, S. M.
    Abdala, Guillermina I.
    Racagni, Graciela E.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (01) : 418 - 426
  • [5] Ceramide profiling of complex lipid mixtures by electrospray ionization mass spectrometry
    Gu, M
    Kerwin, JL
    Watts, JD
    Aebersold, R
    ANALYTICAL BIOCHEMISTRY, 1997, 244 (02) : 347 - 356
  • [6] Electrospray ionization tandem mass spectrometry of chaetoglobosins
    Xu, Guo-Bo
    Li, Li-Mei
    Fang, Dong-Mei
    Li, Guo-You
    Zhang, Guo-Lin
    Wu, Zhi-Jun
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (18) : 2115 - 2122
  • [7] Electrospray ionization and tandem mass spectrometry of eicosanoids
    Murphy, RC
    Barkley, RM
    Berry, KZ
    Hankin, J
    Harrison, K
    Johnson, C
    Krank, J
    McAnoy, A
    Uhlson, C
    Zarini, S
    ANALYTICAL BIOCHEMISTRY, 2005, 346 (01) : 1 - 42
  • [8] Phosphoinositide profiling in complex lipid mixtures using electrospray ionization mass spectrometry
    Markus R Wenk
    Louise Lucast
    Gilbert Di Paolo
    Anthony J Romanelli
    Sharon F Suchy
    Robert L Nussbaum
    Gary W Cline
    Gerald I Shulman
    Walter McMurray
    Pietro De Camilli
    Nature Biotechnology, 2003, 21 : 813 - 817
  • [9] Phosphoinositide profiling in complex lipid mixtures using electrospray ionization mass spectrometry
    Wenk, MR
    Lucast, L
    Di Paolo, G
    Romanelli, AJ
    Suchy, SF
    Nussbaum, RL
    Cline, GW
    Shulman, GI
    McMurray, W
    De Camilli, P
    NATURE BIOTECHNOLOGY, 2003, 21 (07) : 813 - 817
  • [10] Confirmation of the structure of lipid A from Enterobacter agglomerans by electrospray ionization tandem mass spectrometry
    Boué, SM
    Cole, RB
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (03): : 361 - 368