Conjunctival thickness as a predictive imaging biomarker for the glaucoma filtration surgery outcome: An optical coherence tomography study

被引:8
|
作者
Mastropasqua, Leonardo [1 ]
Brescia, Lorenza [1 ]
Oddone, Francesco [2 ]
Sacchi, Matteo [3 ]
Aloia, Raffaella [1 ]
Totta, Michele [1 ]
Scatena, Barbara [1 ]
Mastropasqua, Rodolfo [4 ]
Agnifili, Luca [1 ]
机构
[1] Univ G dAnnunzio, Dept Med & Aging Sci, Ophthalmol Clin, Chieti, Italy
[2] IRCCS Fdn GB Bietti, Rome, Italy
[3] Univ Milan, Univ Eye Clin, San Giuseppe Hosp, Milan, Italy
[4] Univ Modena & Reggio Emilia, Inst Ophthalmol, Modena, Italy
来源
关键词
conjunctival thickness; filtering bleb; filtration surgery; glaucoma; optical coherence tomography; OPEN-ANGLE GLAUCOMA; OCULAR SURFACE; HISTOPATHOLOGY; LATANOPROST; MEDICATION; SUCCESS; TIMOLOL; DRUGS;
D O I
10.1111/ceo.13857
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Importance To analyse the preoperative conjunctival thickness in glaucomatous patients undergoing filtration surgery (FS), using optical coherence tomography (OCT). Background The conjunctival status represents one of the most critical determinants of the FS outcome. Design Retrospective study. Participants Sixty-seven patients candidate to FS for uncontrolled glaucoma were enrolled. Methods OCT was performed at the superior bulbar conjunctiva before FS, and at bleb site at the last follow-up (LF-up) after surgery. Main Outcome Measures Preoperative full, epithelial, and stromal conjunctival thickness (FCT, CET, CST) and reflectivity (CR), and LF-up bleb-wall thickness (BT), reflectivity (BR) and intraocular pressure (IOP), were the major outcomes. The relations between preoperative parameters and LF-up-IOP, BT and BR were calculated. Results FS was completely successful in 23 patients (group 1), successful with medications in 22 (group 2), and failed in 22 (group 3). FCT, CET and CST were lower, whereas CR higher, in group 3 compared to groups 1 and 2 (P < .05); BT was lower (P < .001), whereas BR higher (P < .05) in group 3 compared to group 1. FCT and CST were predictors of FS outcome with lower thickness associated with increased odds of failure (odds ratio 0.922,P= .08; 0.941,P= .025). LF-up-IOP inversely correlated with FCT and CST (r= -0.447,P= .003;r= -0.408,P= .007), whereas positively correlated with CR (r= 0.789,P < .001). Conclusions and Relevance Preoperative conjunctival thickness and reflectivity show significant correlations with the FS outcome, both in terms of IOP and bleb-wall features. Therefore, they may be proposed as predictive imaging biomarkers to estimate the risk of filtration failure.
引用
收藏
页码:1192 / 1200
页数:9
相关论文
共 50 条
  • [1] Anterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery
    Mastropasqua, Rodolfo
    Fasanella, Vincenzo
    Agnifili, Luca
    Curcio, Claudia
    Ciancaglini, Marco
    Mastropasqua, Leonardo
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [2] Optical coherence tomography in malignant glaucoma following filtration surgery
    Wirbelauer, C
    Karandish, A
    Häberle, H
    Pham, DT
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (08) : 952 - 955
  • [3] Conjunctival Thickness Measured by Optical Coherence Tomography
    Zhang, Xing-Ru
    Zhang, Zhen-Yong
    Hoffman, Matthew R.
    [J]. OPHTHALMOLOGY, 2013, 120 (06) : 1305 - 1305
  • [4] In Vivo Confocal Imaging of the Conjunctiva as a Predictive Tool for the Glaucoma Filtration Surgery Outcome
    Mastropasqua, Rodolfo
    Fasanella, Vincenzo
    Brescia, Lorenza
    Oddone, Francesco
    Mariotti, Cesare
    Di Staso, Silvio
    Agnifili, Luca
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (06) : BIO114 - BIO120
  • [5] Optical coherence tomography predictive factors for macular hole surgery outcome
    Ruiz-Moreno, J. M.
    Staicu, C.
    Pinero, D. P.
    Montero, J.
    Lugo, F.
    Amat, P.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (05) : 640 - 644
  • [6] Swept-Source Anterior Segment Optical Coherence Tomography Imaging and Quantification of Bleb Parameters in Glaucoma Filtration Surgery
    Tan, Jeremy C. K.
    Muntasser, Hussameddin
    Choudhary, Anshoo
    Batterbury, Mark
    Vallabh, Neeru A.
    [J]. BIOENGINEERING-BASEL, 2023, 10 (10):
  • [7] Macular imaging with optical coherence tomography in glaucoma
    Mohammadzadeh, Vahid
    Fatehi, Nima
    Yarmohammadi, Adeleh
    Lee, Ji Woong
    Sharifipour, Farideh
    Daneshvar, Ramin
    Caprioli, Joseph
    Nouri-Mahdavi, Kouros
    [J]. SURVEY OF OPHTHALMOLOGY, 2020, 65 (06) : 597 - 638
  • [8] Macular Optical Coherence Tomography Imaging in Glaucoma
    Kamalipour, Alireza
    Moghimi, Sasan
    [J]. JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2021, 16 (03) : 478 - 489
  • [9] Evaluation of Conjunctival Graft Thickness after Pterygium Surgery by Anterior Segment Optical Coherence Tomography
    Kheirkhah, Ahmad
    Adelpour, Mohsen
    Nikdel, Mojgan
    Ghaffari, Reza
    Ghassemi, Hamed
    Hashemi, Hassan
    [J]. CURRENT EYE RESEARCH, 2011, 36 (09) : 782 - 786
  • [10] Comparison of conjunctival graft thickness after primary and recurrent pterygium surgery: Anterior segment optical coherence tomography study
    Ozgurhan, Engin Bilge
    Kara, Necip
    Bozkurt, Ercument
    Gencer, Baran
    Yuksel, Kemal
    Demirok, Ahmet
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (06) : 675 - 679