Pitfalls in normalization for intensity-modulated radiation therapy planning

被引:6
|
作者
Williams, G [1 ]
Tobler, M [1 ]
Leavitt, D [1 ]
机构
[1] Univ Utah, Dept Radiat Oncol, Huntsman Canc Hosp, Hlth Sci Ctr, Salt Lake City, UT 84112 USA
关键词
normalization; intensity-modulated radiotherapy; treatment planning;
D O I
10.1016/j.meddos.2005.06.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Three-dimensional (3D) treatment planning often involves complex combinations of beam energies, treatment fields, and beam modifying devices. Even when a plan is devised that meets many treatment-planning objectives, limitations in the planner's ability to further adjust beam characteristics may require the radiation dose prescription to be normalized to an isodose level that best covers the target volume. While these normalizations help meet the volume coverage goals, they also result in adjustment of the dose delivered to the normal tissues and must be carefully evaluated. Intensity-modulated radiation therapy (IMRT) treatment planning allows combinations of complex dose patterns, in order to achieve the desired treatment planning goals. These dose patterns are created by defining a set of treatment planning objectives and then allowing the treatment planning computer to create intensity patterns, through the use of moving multileaf collimation that will meet the requested goals. Often, when an IMRT treatment plan is created that meets many of the treatment planning goals but falls short of volume coverage requirements, the planner is tempted to apply normalization principles similar to those utilized with 3D treatment planning. Again, these normalizations help meet the volume coverage goals, but unlike 3D planning situations, may result in avoidable delivery of additional doses to the normal tissues. The focus of this study is to evaluate the effect of application of normalization for IMRT planning using multiple patient situations. Recommendations would favor re-optimization over normalization in most planning situations. (c) 2005 American Association of Medical Dosimetrists.
引用
收藏
页码:194 / 200
页数:7
相关论文
共 50 条
  • [1] Planning and delivery of intensity-modulated radiation therapy
    Yu, Cedric X.
    Amies, Christopher J.
    Svatos, Michelle
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5233 - 5241
  • [2] Issues in optimization for planning of intensity-modulated radiation therapy
    Verhey, LJ
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 210 - 218
  • [3] An Automated Intensity-Modulated Radiation Therapy Planning System
    Ahmed, Shabbir
    Gozbasi, Ozan
    Savelsbergh, Martin
    Crocker, Ian
    Fox, Tim
    Schreibmann, Eduard
    [J]. INFORMS JOURNAL ON COMPUTING, 2010, 22 (04) : 568 - 583
  • [4] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Intensity-modulated radiation therapy
    Lewin, DI
    [J]. COMPUTING IN SCIENCE & ENGINEERING, 2002, 4 (05) : 8 - 10
  • [6] Intensity-modulated radiation therapy
    Anon
    [J]. Computing in Science and Engineering, 2002, 4 (05):
  • [7] Intensity-modulated radiation therapy
    Purdy, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04): : 845 - 846
  • [8] Intensity-modulated radiation therapy
    不详
    [J]. CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 47 - 84
  • [9] Intensity-modulated radiation therapy
    Carpini, DD
    [J]. HEALTH PHYSICS, 2001, 81 (04): : 469 - 469
  • [10] Intensity-modulated radiation therapy
    Lee, N. Y.
    Terezakis, S. A.
    [J]. JOURNAL OF SURGICAL ONCOLOGY, 2008, 97 (08) : 691 - 696