A dedicated decay-spectroscopy station for the collinear resonance ionization experiment at ISOLDE

被引:14
|
作者
Rajabali, M. M. [1 ]
Lynch, K. M. [2 ,3 ]
Cocolios, T. E. [3 ]
Billowes, J. [2 ]
Bissell, M. L. [1 ]
De Schepper, S. [1 ]
Dewolf, K. [1 ]
Flanagan, K. T. [2 ]
Le Blanc, F. [4 ]
Marsh, B. A. [5 ]
Mason, P. J. R. [6 ]
Matea, I. [4 ]
Neyens, G. [1 ]
Papuga, J. [1 ]
Procter, T. J. [2 ]
Rothe, S. [5 ,7 ]
Simpson, G. S. [8 ]
Smith, A. J. [2 ]
Stroke, H. H. [9 ]
Verney, D. [4 ]
Walker, P. M. [6 ]
Wendt, K. [7 ]
Wood, R. T. [6 ]
机构
[1] Katholieke Univ Leuven, Inst Kern Stralingsfys, B-3001 Louvain, Belgium
[2] Univ Manchester, Sch Phys & Astron, Manchester M13 9PL, Lancs, England
[3] CERN, Dept Phys, CH-1211 Geneva 23, Switzerland
[4] Univ Paris 11, CNRS, IN2P3, Inst Phys Nucl, F-91405 Orsay, France
[5] CERN, Dept Engn, CH-1211 Geneva 23, Switzerland
[6] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[7] Johannes Gutenberg Univ Mainz, Inst Phys, D-55128 Mainz, Germany
[8] LPSC, F-38026 Grenoble, France
[9] NYU, Dept Phys, New York, NY 10003 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Alpha decay; Fission products; gamma-Ray; Laser-assisted decay spectroscopy; LASER ION-SOURCE; GAS CELL;
D O I
10.1016/j.nima.2012.12.090
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new decay-spectroscopy station (DSS) has been developed to be coupled to the collinear resonance ionization spectroscopy (CRIS) beam line at CERN-ISOLDE. The system uses a rotatable wheel with ten 20 mu g/cm(2) carbon foils as beam implantation sites for the efficient measurement of charged decay products. Silicon detectors are placed on either side of the carbon foil in an optimal geometry to cover a large solid angle for detecting these charged particles. In addition to the silicon detectors at the on-beam axis position, a second pair of off-beam axis detectors are placed at the wheel position 108 degrees away, allowing longer-lived species to be studied. Up to three high purity germanium detectors can be placed around the chamber for particle-gamma correlated measurement. The radioactive beam is transported through the CRIS beam line before implantation into a carbon foil at the DSS. All materials used in the DSS are UHV-compatible to maintain high vacuum conditions required by the CRIS beam line. This paper describes the DSS and presents the first data collected at the setup during the commissioning run with Fr-221. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 25 条
  • [1] A simple decay-spectroscopy station at CRIS-ISOLDE
    Lynch, K. M.
    Cocolios, T. E.
    Althubiti, N.
    Farooq-Smith, G. J.
    Gins, W.
    Smith, A. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 844 : 14 - 18
  • [2] The Collinear Resonance Ionization Spectroscopy (CRIS) experimental setup at CERN-ISOLDE
    Cocolios, T. E.
    Al Suradi, H. H.
    Billowes, J.
    Budincevic, I.
    de Groote, R. P.
    De Schepper, S.
    Fedosseev, V. N.
    Flanagan, K. T.
    Franchoo, S.
    Ruiz, R. F. Garcia
    Heylen, H.
    Le Blanc, F.
    Lynch, K. M.
    Marsh, B. A.
    Mason, P. J. R.
    Neyens, G.
    Papuga, J.
    Procter, T. J.
    Rajabali, M. M.
    Rossel, R. E.
    Rothe, S.
    Simpson, G. S.
    Smith, A. J.
    Strashnov, I.
    Stroke, H. H.
    Verney, D.
    Walker, P. M.
    Wendt, K. D. A.
    Wood, R. T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 565 - 569
  • [3] Optimising the Collinear Resonance Ionisation Spectroscopy (CRIS) experiment at CERN-ISOLDE
    Vernon, A. R.
    de Groote, R. P.
    Billowes, J.
    Binnersley, C. L.
    Cocolios, T. E.
    Farooq-Smith, G. J.
    Flanagan, K. T.
    Ruiz, R. F. Garcia
    Gins, W.
    Koszorus, A.
    Neyens, G.
    Ricketts, C. M.
    Smith, A. J.
    Wilkins, S. G.
    Yang, X. F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 : 384 - 389
  • [4] Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment
    Athanasakis-Kaklamanakisa, Michail
    Reilly, Jordan R.
    Koszorus, Agota
    Wilkins, Shane G.
    Lalanne, Louis
    Geldhofb, Sarina
    Nichols, Miranda
    Wang, Quanjun
    van den Borne, Bram
    Chorlton, David
    Cocolios, Thomas E.
    Flanagan, Kieran T.
    Ruiz, Ronald F. Garcia
    de Groote, Ruben
    Hanstorp, Dag
    Neyens, Gerda
    Smith, Andrew J.
    Vernon, Adam R.
    Yang, Xiaofei F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 541 : 86 - 89
  • [5] COMMISSIONING OF A DECAY-SPECTROSCOPY STATION FOR THE 9 MV TANDEM ACCELERATOR
    Toma, Sebastian
    Sava, Tiberiu
    Ghita, Dan Gabriel
    Marginean, Nicolae Marius
    Cata-Danil, Gheorghe
    Zamfir, Nicolae-Victor
    Moisa, Dorin
    [J]. UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2019, 81 (02): : 245 - 256
  • [6] High-resolution laser spectroscopy with the Collinear Resonance Ionisation Spectroscopy (CRIS) experiment at CERN-ISOLDE
    Cocolios, T. E.
    de Groote, R. P.
    Billowes, J.
    Bissell, M. L.
    Budincevic, I.
    Goodacre, T. Day
    Farooq-Smith, G. J.
    Fedosseev, V. N.
    Flanagan, K. T.
    Franchoo, S.
    Ruiz, R. F. Garcia
    Gins, W.
    Heylen, H.
    Kron, T.
    Li, R.
    Lynch, K. M.
    Marsh, B. A.
    Neyens, G.
    Rossel, R. E.
    Rothe, S.
    Smith, A. J.
    Stroke, H. H.
    Wendt, K. D. A.
    Wilkins, S. G.
    Yang, X.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 376 : 284 - 287
  • [7] The X-Array and SATURN: A new decay-spectroscopy station for CARIBU
    Mitchell, A. J.
    Bertone, P. F.
    DiGiovine, B.
    Lister, C. J.
    Carpenter, M. P.
    Chowdhury, P.
    Clark, J. A.
    D'Olympia, N.
    Deo, A. Y.
    Kondev, F. G.
    McCutchan, E. A.
    Rohrer, J.
    Savard, G.
    Seweryniak, D.
    Zhu, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 763 : 232 - 239
  • [8] Laser-ablation charge exchange for collinear resonance ionization spectroscopy
    Kubota, M
    Isobe, M
    Minowa, T
    Jin, WG
    Katsuragawa, H
    Uematsu, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 149 (04): : 514 - 520
  • [9] Laser-ablation charge exchange for collinear resonance ionization spectroscopy
    Kubota, Masashi
    Isobe, Mitsuto
    Minowa, Tatsuya
    Jin, Wei-Guo
    Katsuragawa, Hidetsugu
    Uematsu, Haruko
    [J]. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1999, 149 (04): : 514 - 520
  • [10] Collinear Resonance Ionization Spectroscopy of Neutron-Deficient Francium Isotopes
    Flanagan, K. T.
    Lynch, K. M.
    Billowes, J.
    Bissell, M. L.
    Budincevic, I.
    Cocolios, T. E.
    de Groote, R. P.
    De Schepper, S.
    Fedosseev, V. N.
    Franchoo, S.
    Ruiz, R. F. Garcia
    Heylen, H.
    Marsh, B. A.
    Neyens, G.
    Procter, T. J.
    Rossel, R. E.
    Rothe, S.
    Strashnov, I.
    Stroke, H. H.
    Wendt, K. D. A.
    [J]. PHYSICAL REVIEW LETTERS, 2013, 111 (21)