Numerical Study on Structural Improvement of the Grill Fixed at the Outlet of the Air Conditioner Outdoor Unit

被引:1
|
作者
Liu, Ying [1 ]
Wu, C. J. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
关键词
Outdoor unit; Improvement; Grill; Computational fluid dynamics;
D O I
10.4028/www.scientific.net/AMM.141.386
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the techniques to numerically simulate the inner flow field of the air conditioner outdoor unit with Fluent. The results are verified experimentally and proved to be mesh-independent. The possibility of improvement to increase the flow rate by modifying the grill's structural parameters is shown through analyzing the numerical results. The gill's structure is improved using the flow field information got from numerical simulation and the improvement helps to increase flow rate by 4.1% and reduces the turbulent intensity near the grill significantly.
引用
收藏
页码:386 / 391
页数:6
相关论文
共 50 条
  • [1] Effect of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner
    Hu, Junwei
    Ding, Guoliang
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1737 - 1745
  • [2] A study on axial flow fan design parameters of air conditioner outdoor unit and the performance improvement
    Chung, MK
    Jin, SW
    Chung, BY
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 856 - 862
  • [3] Experimental and numerical study on aerodynamic noise of outdoor unit of room air conditioner with different grilles
    Tian, Jie
    Ouyang, Hua
    Wu, Yadong
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 1112 - 1122
  • [4] Flow velocity around air-conditioner outdoor unit
    Xu, Chen
    Ou, Chunshan
    Gu, Xiaojiang
    Wang, Chao
    Mao, Yijun
    [J]. Physics of Fluids, 2025, 37 (01)
  • [5] EFFECT OF THE OUTDOOR UNIT ARRANGEMENTS ON COP OF AN AIR-CONDITIONER
    Li, Hao
    Huang, Chen
    Zou, Zhijun
    Wang, Fei
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2273 - 2278
  • [6] REDUCTION OF THE STRUCTURAL NOISE OF AN OUTDOOR AIR CONDITIONER IN A RESIDENTIAL BUILDING
    Dombi, Istvan
    Bite, Maria
    Bite, Pal
    [J]. PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [7] Finite element analysis of dynamic stress of the outdoor unit of air conditioner
    Yang, Rong
    Li, Shiyun
    Zhou, Shaoping
    Guo, Jun
    Zhang, Lanzhu
    Hui, Hu
    [J]. EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 153 - 157
  • [8] User Demand-Oriented Evaluation of Outdoor Unit of Air Conditioner
    Liu, Weilin
    Xu, Chunfeng
    [J]. DIGITAL HUMAN MODELING AND APPLICATIONS IN HEALTH, SAFETY, ERGONOMICS AND RISK MANAGEMENT, PT I, DHM 2024, 2024, 14709 : 295 - 307
  • [9] Experimental and numerical study of electronic module-cooling heat sinks used in a variable frequency air-conditioner outdoor unit
    Zhao, Xifeng
    Sun, Jinju
    Wang, Chao
    Zhang, Zhi
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 : 10 - 21
  • [10] Numerical Simulation for Thermal Distribution of Air-conditioner Outdoor Units
    Tong, Li-Ge
    Zhang, Zhen
    Wang, Li
    Yin, Shao-Wu
    Yu, Jiangfeng
    Liu, Chun
    [J]. JOURNAL OF THERMAL SCIENCE, 2012, 21 (03) : 269 - 275