Design of a Patient-Specific Radiotherapy Treatment Target

被引:1
|
作者
Heyns, Michael [1 ]
Breseman, Kelsey [1 ]
Lee, Christopher [1 ]
Bloch, B. Nicolas
Jaffe, Carl
Xiang, Hong
机构
[1] Franklin W Olin Coll Engn, Needham, MA USA
关键词
prostate; phantom; radiotherapy; patient specific; quality assurance; PHANTOM;
D O I
10.1109/NEBEC.2013.75
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes the design of a patient-specific, radiotherapy quality assurance target that can be used to verify a treatment plan by measurement of actual dosage. Staring from a patient's (segmented) MR images, a physical model containing insertable cartridges for holding dosimeters is printed in 3D. Dosimeters can be located at specific locations of interest (e.g., tumor, nerve bundles, urethra). The model (dosimeter insert) can be placed into a pelvis 'shell' and subject to a specified treatment plan. A design for the dosimeter insert can be efficiently fabricated using rapid prototyping techniques.
引用
收藏
页码:171 / +
页数:2
相关论文
共 50 条
  • [1] Patient-specific treatment planning for intraoperative radiotherapy of glioblastoma
    Alvarez, David Santiago Ayala
    Popovic, Marij
    Heng, Veng Jean
    Watson, Peter G. F.
    Evans, Michael D. C.
    Seuntjens, Jan
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5711 - 5712
  • [2] PATIENT-SPECIFIC QA FOR ADAPTIVE RADIOTHERAPY
    van Elmpt, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S234 - S234
  • [3] Patient-specific radiotherapy quality assurance for estimating actual treatment dose
    Tanabe, Yoshinori
    Ishida, Takayuki
    Eto, Hidetoshi
    Sera, Tatsuhiro
    Emoto, Yuki
    Shimokawa, Mototsugu
    [J]. MEDICAL DOSIMETRY, 2021, 46 (01) : e5 - e10
  • [4] DESIGN AND USE OF PATIENT-SPECIFIC ATLASES FOR RADIOTHERAPY PLANNING OF THE HEAD AND NECK REGION
    Ramus, L.
    Aouadi, S.
    Gregoire, V.
    Malandain, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S513 - S513
  • [5] MMCTP: a radiotherapy research environment for Monte Carlo and patient-specific treatment planning
    Alexander, A.
    DeBlois, F.
    Stroian, G.
    Al-Yahya, K.
    Heath, E.
    Seuntjens, J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13): : N297 - N308
  • [6] Patient-specific dosimetric endpoints based treatment plan quality control in radiotherapy
    Song, Ting
    Staub, David
    Chen, Mingli
    Lu, Weiguo
    Tian, Zhen
    Jia, Xun
    Li, Yongbao
    Zhou, Linghong
    Jiang, Steve B.
    Gu, Xuejun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8213 - 8227
  • [7] Patient-Specific Prediction Guided Automatic Treatment Planning for Intensity Modulated Radiotherapy
    Mai, Y.
    Li, Y.
    Zhou, L.
    Song, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2905 - 2905
  • [8] MMCTP, a radiotherapy research environment for Monte Carlo and patient-specific treatment planning
    Alexander, A.
    DeBlois, F.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2293 - 2293
  • [9] A practical method for predicting patient-specific collision in radiotherapy
    Miao, Junjie
    Niu, Chuanmeng
    Liu, Zhiqiang
    Tian, Yuan
    Dai, Jianrong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 65 - 72
  • [10] Patient-Specific Quality Assurance Techniques for RapidArc Radiotherapy
    O'Daniel, J.
    McMahon, R.
    Chang, Z.
    Yan, H.
    Sakhalkar, H.
    Das, S.
    Wu, Q.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)