A Method for Improving Signal-to-Noise Ratio of Tissue Harmonic Imaging Based on Bayesian Inference Using Information of Fundamental Echoes

被引:12
|
作者
Yamamura, Takuya [1 ]
Tanabe, Masayuki [2 ]
Okubo, Kan [1 ]
Tagawa, Norio [1 ]
机构
[1] Tokyo Metropolitan Univ, Grad Sch Syst Design, Hino, Tokyo 1910065, Japan
[2] Kumamoto Univ, Grad Sch Sci & Technol, Kumamoto 8608555, Japan
关键词
D O I
10.1143/JJAP.51.07GF01
中图分类号
O59 [应用物理学];
学科分类号
摘要
A medical ultrasound imaging technique with a high spatial resolution and a high signal-to-noise ratio (SNR) is strongly required for precise diagnosis. To obtain high-resolution images, tissue harmonic imaging (THI) can be effectively adopted because of its wide bandwidth characteristics compared with fundamental imaging. However, the amplitude of harmonic components is much smaller than that of a fundamental component. Additionally, frequency dependent attenuation is severe, especially for harmonic components. These phenomena mean that THI is susceptible to noise. From these considerations, in this study, we propose a method for improving the SNR of THI by reducing noise using a signal processing technique. The proposed method is constructed based on the Bayesian inference using fundamental components of echoes, and it can hold the high-resolution nature of THI. We show the effectiveness of the proposed method through simulations. (C) 2012 The Japan Society of Applied Physics
引用
收藏
页数:11
相关论文
共 50 条
  • [1] New tissue harmonic imaging scheme with better fundamental frequency cancellation and higher signal-to-noise ratio
    Siemens Medical Systems, Inc, Issaquah, United States
    [J]. Proceedings of the IEEE Ultrasonics Symposium, 1998, 2 : 1589 - 1594
  • [2] A new tissue harmonic imaging scheme with better fundamental frequency cancellation and higher signal-to-noise ratio
    Jiang, P
    Mao, ZH
    Lazenby, JC
    [J]. 1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1589 - 1594
  • [3] IMPROVING DISPLACEMENT SIGNAL-TO-NOISE RATIO FOR LOW-SIGNAL RADIATION FORCE ELASTICITY IMAGING USING BAYESIAN TECHNIQUES
    Dumont, Douglas M.
    Walsh, Kristy M.
    Byram, Brett C.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (08): : 1986 - 1997
  • [4] Improving signal-to-noise ratio performance of compressive imaging based on spatial correlation
    Tianyi Mao
    Qian Chen
    Weiji He
    Yunhao Zou
    Huidong Dai
    Guohua Gu
    [J]. Optical Review, 2016, 23 : 571 - 578
  • [5] Improving signal-to-noise ratio performance of compressive imaging based on spatial correlation
    Mao, Tianyi
    Chen, Qian
    He, Weiji
    Zou, Yunhao
    Dai, Huidong
    Gu, Guohua
    [J]. OPTICAL REVIEW, 2016, 23 (04) : 571 - 578
  • [6] Improving the signal-to-noise ratio of complementary compressive imaging with a threshold
    Xue, Chang-Bin
    Yao, Xu-Ri
    Liu, Xue-Feng
    Zhai, Guang-Jie
    Zhao, Qing
    Guo, Xiao-Yong
    [J]. OPTICS COMMUNICATIONS, 2017, 393 : 118 - 122
  • [7] A method of improving signal-to-noise ratio in spectrally encoded microscopy
    Liao, Jiuling
    Gao, Wanrong
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (03):
  • [8] Improving photoacoustic imaging in low signal-to-noise ratio by using spatial and polarity coherence
    Mao, Qiuqin
    Zhao, Weiwei
    Qian, Xiaoqin
    Tao, Chao
    Liu, Xiaojun
    [J]. PHOTOACOUSTICS, 2022, 28
  • [9] Improving the signal-to-noise ratio of single-pixel imaging using digital microscanning
    Sun, Ming-Jie
    Edgar, Matthew P.
    Phillips, David B.
    Gibson, Graham M.
    Padgett, Miles J.
    [J]. OPTICS EXPRESS, 2016, 24 (10): : 10476 - 10485
  • [10] Improving the Signal-to-Noise Ratio of Superresolution Imaging Based on Single-Pixel Camera
    Wei, Ziran
    Zhang, Jianlin
    Xu, Zhiyong
    Liu, Yong
    Huang, Yongmei
    Fan, Xiangsuo
    [J]. IEEE PHOTONICS JOURNAL, 2019, 11 (01):