Solar distillation is the lowest energy consuming desalination process as it only uses heat from solar radiation. In this study, a solar still is developed to utilize maximum solar irradiation to evaporate water andincrease the rate of condensation by an external condenser. The system is improved by modifying absorber plate with rectangular and triangular channels. This increases surface area of the absorber plate for increasing heat transfer between basin and basin water as well as surface to volume ratio of basin water. To increase condensation of vapor, the effect of an external condenser cooled by feed water is also tested. Feed water flows through the copper tubes of the condenser, cools it and maintains its temperature always below dew point. The condenser also provides extended surface area for condensation when glass surface condensation rate decreases due to excessive film condensation. The water inside tubes of the condenser pick up latent heat of condensation from the vapor condensed on its surface and preheat water. The water is further preheated by solar collector before entering the still. The experiments have been conducted to test the effect of the condenser on overall distillate output against primary glass surface condenseroutput during various temperatures of the glass surface. Different designs of absorber plate are testedfor their effects on rate of evaporation under various hours and weather conditions of several days at Rajshahi, Bangladesh. The maximum average yield obtained is 3.15 L/m(2) with triangular channeled absorber plate. The effect of using the external condenser also increased the productivity by 24-30%.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Thermal performance analysis of a solar still with different absorber plates and external copper condenser
    Nehar, Lailatul
    Rahman, Tanvir
    Tuly, S. S.
    Rahman, Md Sazan
    Sarker, M. R. I.
    Beg, M. R. A.
    [J]. GROUNDWATER FOR SUSTAINABLE DEVELOPMENT, 2022, 17
  • [2] Performance analysis of single slope solar still for different surface geometry of basin absorber
    Mishra, Kuber Nath
    Tiwari, Anil Kr.
    Tiwari, G. N.
    [J]. DESALINATION AND WATER TREATMENT, 2022, 265 : 1 - 17
  • [3] Investigation of the effect of different absorber plate configurations of hemispherical solar still
    Taheri Mousavi, Seyed Mahdi
    [J]. Renewable Energy, 2024, 237
  • [4] Experimental investigation on the negative effect of the external condenser on the conventional solar still performance
    Rahmani, Ahmed
    Khemmar, Fouzia
    Saadi, Zine
    [J]. DESALINATION, 2021, 501
  • [5] Effect of absorber plate surface shape and glass cover inclination angle on the performance of a passive solar still
    Goshayeshi, Hamid Reza
    Safaei, Mohammad Reza
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2020, 30 (06) : 3183 - 3198
  • [6] Performance enhancement and economic analysis of pyramid solar still with corrugated absorber plate and conventional solar still: A case study
    Nuclear Engineering Department, Faculty of Engineering, King Abdulaziz University, Jeddah, Saudi Arabia
    不详
    不详
    不详
    不详
    31527, Egypt
    [J]. Case Stud. Therm. Eng., 2214,
  • [7] Performance enhancement and economic analysis of pyramid solar still with corrugated absorber plate and conventional solar still: A case study
    Ghandourah, Emad
    Panchal, Hitesh
    Fallatah, Othman
    Ahmed, Haitham M.
    Moustafa, Essam B.
    Elsheikh, Ammar H.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 35
  • [8] Performance of single slope solar still with solar protected condenser
    Al-Hamadani, Ali
    Shukla, S.
    [J]. Distributed Generation and Alternative Energy Journal, 2013, 28 (02): : 6 - 28
  • [9] Performance evaluation of an inverted absorber solar still integrated with a refrigeration cycle and an inverted absorber solar still
    Abdul-Wahab, Sabah A.
    Al-Hatmi, Yousuf Y.
    [J]. ENERGY FOR SUSTAINABLE DEVELOPMENT, 2013, 17 (06) : 642 - 648
  • [10] Numerical and experimental study of a passive solar still integrated with an external condenser
    Rahmani, Ahmed
    Boutriaa, Abdelouahab
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (08) : 29047 - 29055