Behavior and fate of As, Se, and Cd in an ultra-low emission coal-fired power plant

被引:64
|
作者
Chang, Lin [1 ]
Yang, Jianping [2 ]
Zhao, Yongchun [1 ]
Liu, Huan [1 ]
Zhang, Junying [1 ]
Zheng, Chuguang [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, State Key Lab Coal Combust, Wuhan, Hubei, Peoples R China
[2] Cent S Univ, Sch Energy Sci & Engn, Changsha, Hunan, Peoples R China
基金
国家重点研发计划;
关键词
Trace element; Removal; Air pollution control device (APCD); Ultra-low emission; Coal-fired power plant; HAZARDOUS TRACE-ELEMENTS; FLUE-GAS DESULFURIZATION; FLY-ASH; PARTICULATE MATTER; MERCURY; COMBUSTION; HG; SPECIATION; CR; REDUCTION;
D O I
10.1016/j.jclepro.2018.10.270
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Environmental concerns regarding the toxicity of trace elements (TEs) and the harmful effects of these elements on humans have attracted worldwide attention. To meet stricter environmental policies, some coal-fired power plants have installed ultra-low emission equipment. In this paper, the behavior and fate of the trace elements As, Se, and Cd originating in an ultra-low emission coal-fired power plant equipped with air pollution control devices (APCDs), including selective catalytic reduction (SCR) equipment, a low-temperature economizer (LTE), an electrostatic precipitator (ESP), a wet flue gas desulfurization (WFGD) system, and a wet electrostatic precipitator (WESP), were investigated. Onsite samples of the feed coal, bottom ash, fly ash, gypsum, desulfurization slurry, WFGD effluent, WFGD-treated water, and WESP effluent were systematically collected and analyzed. The SCR and LTE configurations achieved a partial removal of As, Se, and Cd. The ESP trapped virtually all the particles and had a synergistic effect on the removal of the TEs. A systematic study of the recycling of the desulfurization slurry revealed TE enrichment in the WFGD system; because it concentrated in the liquid fraction of the gypsum slurry, Se was particularly susceptible to this enrichment. The effluent water treatment system achieved TE removal with efficiencies exceeding 94%. WESP operation achieved extensive removal of TE-enriched particles with percentages greater than 90%. The overall efficiencies of As, Se, and Cd removal obtained by the APCD system as a whole were 95.94%, 98.22%, and 92.70%, respectively. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:722 / 730
页数:9
相关论文
共 50 条
  • [1] Fine Particulate Emission Characteristics of an Ultra-Low Emission Coal-Fired Power Plant
    Wang, Run-Fang
    Ma, Da-Wei
    Jiang, Shao-Yi
    Zhu, Ren-Bin
    He, Jun
    Zhang, Ben-Yao
    [J]. Huanjing Kexue/Environmental Science, 2020, 41 (01): : 98 - 105
  • [2] Arsenic emission and distribution characteristics in the ultra-low emission coal-fired power plant
    Lipeng Han
    Yi Zhao
    Runlong Hao
    [J]. Environmental Science and Pollution Research, 2022, 29 : 36814 - 36823
  • [3] Arsenic emission and distribution characteristics in the ultra-low emission coal-fired power plant
    Han, Lipeng
    Zhao, Yi
    Hao, Runlong
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (24) : 36814 - 36823
  • [4] Particle Removal Characteristics of an Ultra-low Emission Coal-fired Power Plant
    Ruan, Ren-Hui
    Tan, Hou-Zhang
    Duan, Yu-Feng
    Du, Yong-Le
    Liu, He-Xin
    Xiao, Jia-Fan
    Yang, Fu-Xin
    Zhang, Peng
    [J]. Huanjing Kexue/Environmental Science, 2019, 40 (01): : 126 - 134
  • [5] Impact of ultra-low emission retrofitting on partitioning and emission behavior of chromium in a Chinese coal-fired power plant
    Tang, Quan
    Chang, Liru
    He, Fang
    Miao, Chunhui
    Zheng, Liugen
    Ma, Dawei
    Wang, Runfang
    Fu, Biao
    [J]. CHEMOSPHERE, 2022, 302
  • [6] Synergetic removal characteristics of mercury for ultra-low emission coal-fired power plant
    Wu, Yanli
    Chang, Wenrui
    Millan, Marcos
    Hao, Yanhong
    [J]. FUEL, 2023, 332
  • [7] Pollutants Emission Characteristics of an Ultra-low Coal-fired Power Unit
    Li Bing
    Song Yongqiang
    Zhang Qilong
    Zhou Can
    Duan Haoran
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND RENEWABLE ENERGY (ICERE 2018), 2018, 159
  • [8] Migration and removal characteristics of SO3 in ultra-low emission coal-fired power plant
    Feng, Peng
    Li, Zhenghong
    Liu, Hexin
    Tan, Houzhang
    Zhang, Sicong
    Lu, Xuchao
    Yang, Fuxin
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2020, 39 (11): : 4660 - 4667
  • [9] Review on occurrence, speciation, transition and fate of sulfur in typical ultra-low emission coal-fired power plants
    Zhou, Zhiyong
    Lu, Jianyi
    Feng, Qian
    Liu, Wenting
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2022, 100 : 259 - 276
  • [10] Distribution and emission of speciated volatile organic compounds from a coal-fired power plant with ultra-low emission technologies
    Liu, Jun
    Wang, Jiawei
    Cheng, Jie
    Zhang, Yongsheng
    Wang, Tao
    Pan, Wei-Ping
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 264