Experimental Validation of the Multiphysics Modelling of Radiofrequency Ablation using Physical Phantom

被引:0
|
作者
Thipayawat, Tawanwart [1 ]
Duc Nguyen Minh [1 ]
Prinable, Joseph [1 ]
McEwan, Alistair [1 ]
Barry, Tony [2 ]
机构
[1] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[2] Westmead Hosp, Dept Cardiol, Sydney, NSW 2145, Australia
关键词
DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES;
D O I
10.1109/embc.2019.8856962
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spastic Cerebral Palsy is the most common type of Cerebral Palsy (CP) that affects muscle coordination and control. Using Radiofrequency Ablation (RFA) to target the motor branches of the median and ulnar nerve may provide an additional treatment to Botulinum Toxin for spasticity in the hand. However, there are a limited number of studies that report the use of RFA in treating upper-limb spasticity. This prompts the need to establish a simulation model that has been tested against physical phantom to help determine the efficacy of RFA as a treatment for spasticity. In this study, a 3D COMSOL Multiphysics model of a commercial RF probe was validated against a Thermochromic Liquid Crystal (TLC) homogeneous gel phantom. The results of the COMSOL model were compared to the TLC phantom in terms of temperature (0.42 +/- 1.06 degrees C for the TLC high temperature range and -1.90 +/- 0.88 degrees C for the TLC low temperature range), lesion shape (14.5 +/- 5.0%) and lesion size (0.18 +/- 0.06 mm). These results show that COMSOL Multiphysics may be feasible as a tool to characterise RF lesions if the reported errors are accounted for. Further work is required to develop a more complex COMSOL model that incorporates different tissue aspects. However, this is a first step to establishing a validated COMSOL model of a RF probe in homogeneous muscle tissue.
引用
收藏
页码:154 / 157
页数:4
相关论文
共 50 条
  • [1] Validation of a CT-guided intervention robot for biopsy and radiofrequency ablation: experimental study with an abdominal phantom
    Won, Hyung Jin
    Kim, Namkug
    Kim, Guk Bae
    Seo, Joon Beom
    Kim, Hongho
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2017, 23 (03) : 233 - 237
  • [2] Multiphysics modelling and experimental validation of high concentration photovoltaic modules
    Theristis, Marios
    Fernandez, Eduardo F.
    Sumner, Mike
    O'Donovan, Tadhg S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 139 : 122 - 134
  • [3] MR guided radiofrequency ablation with a multiple wire array - A phantom validation study
    Daniel, BL
    Butts, K
    McLaughlin, GW
    Nichols, CJ
    Kermit, EL
    Glover, GH
    [J]. RADIOLOGY, 1997, 205 : 1555 - 1555
  • [4] A polyacrylamide gel phantom for radiofrequency ablation
    Zhang Bu-Lin
    Hu Bing
    Kuang Sheng-Li
    Ying Huang
    Wu Rong
    Li Jia
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2008, 24 (07) : 568 - 576
  • [5] Analytical Validation of COMSOL Multiphysics for Theoretical Models of Radiofrequency Ablation Including the Hyperbolic Bioheat Transfer Equation
    Rivera, Maria J.
    Lopez Molina, Juan A.
    Trujillo, Macarena
    Romero-Garcia, Vicente
    Berjano, Enrique J.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3214 - 3217
  • [6] NUMERICAL-MODEL FOR RADIOFREQUENCY ABLATION OF THE ENDOCARDIUM AND ITS EXPERIMENTAL VALIDATION
    LABONTE, S
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) : 108 - 115
  • [7] Development and validation of an experimental model for the assessment of radiofrequency ablation of pancreatic parenchyma
    Date, RS
    Biggins, J
    Paterson, I
    Denton, J
    McMahon, RF
    Siriwardena, AK
    [J]. PANCREAS, 2005, 30 (03) : 266 - 271
  • [8] Multiphysics modelling and experimental validation of an air-coupled array of PMUTs with residual stresses
    Massimino, G.
    Colombo, A.
    D'Alessandro, L.
    Procopio, F.
    Ardito, R.
    Ferrera, M.
    Corigliano, A.
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2018, 28 (05)
  • [9] Multiphysics modelling and experimental validation of a bi-axial magnetoelectric vibration energy harvester
    McLeod, Joshua E.
    Moss, Scott D.
    [J]. STRUCTURAL HEALTH MONITORING: RESEARCH AND APPLICATIONS, 2013, 558 : 465 - +
  • [10] A DEPLOYABLE MULTI-TINE ENDOSCOPIC RADIOFREQUENCY ABLATION ELECTRODE: SIMULATION VALIDATION IN A THERMOCHROMIC TISSUE PHANTOM
    Hanks, Bradley
    Azhar, Fariha
    Frecker, Mary
    Clement, Ryan
    Greaser, Jenna
    Snook, Kevin
    [J]. 2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,