The use of helical heat exchanger for heat recovery domestic water-cooled air-conditioners

被引:16
|
作者
Yi Xiaowen [1 ]
Lee, W. L. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Domestic water-cooled air-conditioner; Helical heat exchanger; Heat recovery; Wilson plot; Energy efficiency; PRESSURE-DROP; PIPE; COEFFICIENTS; CONVECTION; FLOW; TUBE;
D O I
10.1016/j.enconman.2008.09.039
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study on the performance of a domestic water-cooled air-conditioner (WAC) using tube-in-tube helical heat exchanger for preheating of domestic hot water was carried out. The main aims are to identify the comprehensive energy performance (space cooling and hot water preheating) of the WAC and the optimum design of the helical heat exchanger taking into account the variation in tap water flow rate. A split-type WAC was set up for experimental study at different indoor and outdoor conditions. The cooling output, the amount of recovered heat, and the power consumption for different hot water flow rates were measured. The experimental results showed that the cooling coefficient of performance (COP) of the WAC improves with the inclusion of the heat recovery option by a minimum of 12.3%. This can be further improved to 20.6% by an increase in tap water flow rate. Same result was observed for the comprehensive COP of the WAC. The maximum achievable comprehensive COP was 4.92 when the tap water flow rate was set at 7.7 L/min. The overall heat transfer coefficient of the helical heat exchanger under various operating conditions were determined by Wilson plot. A mathematical model relating the over all heat transfer coefficient to the outer pipe diameter was established which provides a convenient way of optimising the design of the helical heat exchanger. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:240 / 246
页数:7
相关论文
共 50 条
  • [1] Performance evaluation of heat recovery condensor for application in domestic water-cooled air-conditioners
    Yi Xiaowen
    Lee Wailing
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 942 - 948
  • [2] Design and characterization of a cylindrical, water-cooled heat sink for thermoelectric air-conditioners
    Riffat, SB
    Qiu, GQ
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (02) : 67 - 80
  • [3] Modeling the performance characteristics of water-cooled air-conditioners
    Lee, W. L.
    Chen, Hua
    Yik, F. W. H.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (08) : 1456 - 1465
  • [4] STUDY AND MODERNIZATION OF AIR-CONDITIONERS WITH A WET HEAT EXCHANGER
    MENYHART, J
    HOMONNAY, G
    ZOLD, A
    [J]. PERIODICA POLYTECHNICA-ENGINEERING, 1968, 12 (01): : 91 - &
  • [5] Application of water-cooled room air-conditioners in high rise residential buildings
    Wu, HB
    Zhu, YX
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 61 - 64
  • [6] RESIDENTIAL INVERTER AIR-CONDITIONERS WITH HEAT-STORAGE
    MORITA, K
    MATSUZAKA, T
    ISHIDA, T
    [J]. PROCEEDINGS OF THE 40TH ANNUAL INTERNATIONAL APPLIANCE TECHNICAL CONFERENCE, 1989, : 297 - 308
  • [7] Influence of the Water-Cooled Heat Exchanger on the Performance of a Pulse Tube Refrigerator
    Wang, Wei
    Hu, Jianying
    Xu, Jingyuan
    Zhang, Limin
    Luo, Ercang
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (03):
  • [8] Sustainability in Energy and Water: Air-Cooled versus Water-Cooled Heat Rejection
    Hawit, Omar
    Jaffe, Trevor
    Pais, Coral
    [J]. 2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [9] PROTECTION OF WATER-COOLED HEAT-EXCHANGER SYSTEMS AGAINST CORROSION BY INHIBITORS
    RONAY, D
    VARGA, Z
    [J]. MAGYAR KEMIKUSOK LAPJA, 1974, 29 (09): : 489 - 494
  • [10] Air- and water-cooled guns for high-heat applications
    Villafuerte, Julio
    [J]. Welding Journal (Miami, Fla), 2001, 80 (12): : 32 - 35