Quantitative ultrasound measurements of the tibia and calcaneus in comparison with DXA measurements at various skeletal sites

被引:51
|
作者
Tromp, AM
Smit, JH
Deeg, DJH
Lips, P
机构
[1] Vrije Univ Amsterdam, Inst Res Extramural Med EMGO Inst, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Sociol & Social Gerontol, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Psychiat, Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Dept Endocrinol, Amsterdam, Netherlands
关键词
anthropometry; calcaneus; dual-energy X-ray absorptiometry; quantitative ultrasound; tibia;
D O I
10.1007/s001980050142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The performance of quantitative ultrasound (QUS) measurements of the tibia and calcaneus was studied in 109 elderly people (age range 65-87 years). Broadband ultrasound attenuation (BUA) and speed of sound (SOS) were measured at the calcaneus and SOS was assessed at the tibia. Short-term precision of tibial QUS was studied in 16 volunteers. The coefficient of variation (CV) was 0.4% and the standardized CV (sCV) was 4.4%. We compared the calcaneal and tibial QUS measurements with bone mineral density (BMD) measurements of the lumbar spine, femoral neck, trochanter and total body assessed by dual-energy Xray absorptiometry (DXA). Calcaneal QUS correlated better with BMD at various skeletal sites than tibial QUS. Calcaneal BUA showed higher correlations with BMD values of the lumbar spine, femoral neck, trochanter and total body than calcaneal and tibial SOS (r = 0.48-0.64, r = 0.30-0.47, r = 0.35-0.47, respectively; p<0.001). Body weight modified the relationships between calcaneal and tibial QUS and BMD measurements of the hip. Higher body weight was associated with higher BMD values at the femoral neck and trochanter for the same calcaneal and tibial QUS values. After adjustments for body weight correlations of tibial and calcaneal QUS with BMD improved and were very similar. This suggests; that correction for body weight is important and could add to the predictive value of QUS measurements.
引用
收藏
页码:230 / 235
页数:6
相关论文
共 50 条
  • [1] Quantitative Ultrasound Measurements of the Tibia and Calcaneus in Comparison with DXA Measurements at Various Skeletal Sites
    A. M. Tromp
    J. H. Smit
    D. J. H. Deeg
    P. Lips
    [J]. Osteoporosis International, 1999, 9 : 230 - 235
  • [2] In Vivo MRI Measurements of Bone Quality in the Calcaneus: A Comparison with DXA and Ultrasound
    C. Kang
    M. Paley
    R. Ordidge
    R. Speller
    [J]. Osteoporosis International, 1999, 9 : 65 - 74
  • [3] In vivo MRI measurements of bone quality in the calcaneus: A comparison with DXA and ultrasound
    Kang, C
    Paley, M
    Ordidge, R
    Speller, R
    [J]. OSTEOPOROSIS INTERNATIONAL, 1999, 9 (01) : 65 - 74
  • [4] Comparison of Quantitative Ultrasound Measurements in Calcaneus with DXA and SXA at Other Skeletal Sites: A Population-Based Study on 280 Children Aged 11–16 Years
    M. Sundberg
    P. Gärdsell
    O. Johnell
    E. Ornstein
    I. Sernbo
    [J]. Osteoporosis International, 1998, 8 : 410 - 417
  • [5] Comparison of quantitative ultrasound measurements in calcaneus with DXA and SXA at other skeletal sites:: A population-based study on 280 children aged 11-16 years
    Sundberg, M
    Gärdsell, P
    Johnell, O
    Ornstein, E
    Sernbo, I
    [J]. OSTEOPOROSIS INTERNATIONAL, 1998, 8 (05) : 410 - 417
  • [6] Comparison of bone mineral density at various skeletal sites with quantitative ultrasound parameters of the calcaneus for assessment of vertebral fractures
    Yasuyo Hamanaka
    Itsuo Yamamoto
    Masahiko Takada
    Ryoji Matsushita
    Toyotsugu Ota
    Itsuaki Yuh
    Rikushi Morita
    [J]. Journal of Bone and Mineral Metabolism, 1999, 17 : 195 - 200
  • [7] Comparison of bone mineral density at various skeletal sites with quantitative ultrasound parameters of the calcaneus for assessment of vertebral fractures
    Hamanaka, Y
    Yamamoto, I
    Takada, M
    Matsushita, R
    Ota, T
    Yuh, I
    Morita, R
    [J]. JOURNAL OF BONE AND MINERAL METABOLISM, 1999, 17 (03) : 195 - 200
  • [8] In-vivo MRI measurements of T2' in the calcaneus: A comparison with DXA and ultrasound.
    Kang, C
    Paley, M
    Ordidge, R
    Speller, R
    Hornby, S
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : T646 - T646
  • [9] A new quantitative ultrasound device (Sunlight Omnisense):: comparison with calcaneus ultrasound and DXA
    Guadalix, S.
    Gomez-Juaristi, M.
    Martinez Diaz-Guerra, G.
    Jodar, E.
    Hawkins, F.
    Puente, D.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2007, 18 : S157 - S157
  • [10] QUANTITATIVE ULTRASOUND OF THE HEEL - CORRELATION WITH DENSITOMETRIC MEASUREMENTS AT DIFFERENT SKELETAL SITES
    FAULKNER, KG
    MCCLUNG, MR
    COLEMAN, LJ
    KINGSTONSANDAHL, E
    [J]. OSTEOPOROSIS INTERNATIONAL, 1994, 4 (01) : 42 - 47