Automatic crystal centring procedure at the SSRF macromolecular crystallography beamline

被引:57
|
作者
Wang, Zhijun [1 ]
Pan, Qiangyan [1 ]
Yang, Lifeng [1 ]
Zhou, Huan [1 ]
Xu, Chunyan [1 ]
Yu, Feng [1 ]
Wang, Qisheng [1 ]
Huang, Sheng [1 ]
He, Jianhua [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201204, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
crystal centre; algorithm; recognition; crystallography; loop centre; X-RAY-DIFFRACTION; DATA-COLLECTION; PROTEIN CRYSTALLOGRAPHY; BIOLOGICAL MACROMOLECULES; EXCHANGE; SYSTEM; ICE;
D O I
10.1107/S160057751601451X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray diffraction is a common technique for determining crystal structures. The average time needed for the solution of a protein structure has been drastically reduced by a number of recent experimental and theoretical developments. Since high-throughput protein crystallography benefits from full automation of all steps that are carried out on a synchrotron beamline, an automatic crystal centring procedure is important for crystallographic beamlines. Fully automatic crystal alignment involves the application of optical methods to identify the crystal and move it onto the rotation axis and into the X-ray beam. Crystal recognition has complex dependencies on the illumination, crystal size and viewing angles due to effects such as local shading, inter-reflections and the presence of antifreezing elements. Here, a rapid procedure for crystal centring with multiple cameras using region segment thresholding is reported. Firstly, a simple illumination-invariant loop recognition and classification model is used by slicing a low-magnification loop image into small region segments, then classifying the loop into different types and aligning it to the beam position using feature vectors of the region segments. Secondly, an edge detection algorithm is used to find the crystal sample in a high-magnification image using region segment thresholding. Results show that this crystal centring method is extremely successful under fluctuating light states as well as for poorly frozen and opaque samples. Moreover, this crystal centring procedure is successfully integrated into the enhanced Blu-Ice data collection system at beamline BL17U1 at the Shanghai Synchrotron Radiation Facility as a routine method for an automatic crystal screening procedure.
引用
收藏
页码:1323 / 1332
页数:10
相关论文
共 50 条
  • [1] The macromolecular crystallography beamline of SSRF
    Wang Qi-Sheng
    Yu Feng
    Huang Sheng
    Sun Bo
    Zhang Kun-Hao
    Liu Ke
    Wang Zhi-Jun
    Xu Chun-yan
    Wang Si-Sheng
    Yang Li-Feng
    Pan Qiang-Yan
    Li Liang
    Zhou Huan
    Cui Yin
    Xu Qin
    Earnest, Thomas
    He Jian-Hua
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (01) : 12 - 17
  • [2] The macromolecular crystallography beamline of SSRF
    汪启胜
    郁峰
    黄胜
    孙波
    张坤浩
    刘科
    王志军
    徐春艳
    王思胜
    杨利峰
    潘强岩
    李良
    周欢
    崔莹
    徐琴
    Thomas Earnest
    何建华
    [J]. Nuclear Science and Techniques, 2015, 26 (01) : 12 - 17
  • [3] A Level-2 Biosafety Beamline for Macromolecular Crystallography at SSRF
    Wang Qisheng
    Xu Chunyan
    Zhang Kunhao
    Ke Liu
    He Jianhua
    [J]. 13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [4] Implementation of level-2 biosafety for a macromolecular crystallography beamline at SSRF
    Kong, Huating
    Li, Minjun
    Xu, Qin
    Zhou, Huan
    Yu, Feng
    Wang, Qisheng
    [J]. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 11 (06): : 529 - 536
  • [5] An integrated remote data collection system for macromolecular crystallography beamline at SSRF
    Wang, Qisheng
    Sun, Bo
    Zhou, Huan
    Wang, Zhijun
    Yu, Feng
    He, Jianhua
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 914 : 42 - 45
  • [6] Upgrade of macromolecular crystallography beamline BL17U1at SSRF
    Qi-Sheng Wang
    Kun-Hao Zhang
    Yin Cui
    Zhi-Jun Wang
    Qiang-Yan Pan
    Ke Liu
    Bo Sun
    Huan Zhou
    Min-Jun Li
    Qin Xu
    Chun-Yan Xu
    Feng Yu
    Jian-Hua He
    [J]. Nuclear Science and Techniques, 2018, 29 (05) : 3 - 9
  • [7] Upgrade of macromolecular crystallography beamline BL17U1 at SSRF
    Wang, Qi-Sheng
    Zhang, Kun-Hao
    Cui, Yin
    Wang, Zhi-Jun
    Pan, Qiang-Yan
    Liu, Ke
    Sun, Bo
    Zhou, Huan
    Li, Min-Jun
    Xu, Qin
    Xu, Chun-Yan
    Yu, Feng
    He, Jian-Hua
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (05)
  • [8] Upgrade of macromolecular crystallography beamline BL17U1 at SSRF
    Qi-Sheng Wang
    Kun-Hao Zhang
    Yin Cui
    Zhi-Jun Wang
    Qiang-Yan Pan
    Ke Liu
    Bo Sun
    Huan Zhou
    Min-Jun Li
    Qin Xu
    Chun-Yan Xu
    Feng Yu
    Jian-Hua He
    [J]. Nuclear Science and Techniques, 2018, 29
  • [9] In-situ energy calibration of SSRF macromolecular crystallography beamline using powder diffraction
    Tao Shixing
    Zhu Jing
    Niu Jing
    Chen Mingzhi
    Liu Ke
    Wang Yu
    Wang Qisheng
    Sun Bo
    Huang Sheng
    Tang Lin
    He Jianhua
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2010, 21 (06) : 321 - 324