Methodology for the independent calibration of Raman backscatter water-vapor lidar systems

被引:63
|
作者
Sherlock, V
Hauchecorne, A
Lenoble, J
机构
[1] CNRS, Serv Aeron, F-91371 Verrieres Le Buisson, France
[2] Univ Lille 1, Opt Atmospher Lab, F-59655 Villeneuve Dascq, France
关键词
D O I
10.1364/AO.38.005816
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a method for the independent calibration of Raman backscatter water-vapor lidar systems. Particular attention is given to the resolution of instrumental changes in the short and the long terms. The method reposes on the decomposition of the instrument function, which allows the lidar calibration coefficient to be re-expressed as the product of two terms, one describing the instrumental transmission and detection efficiency and the other describing the wavelength-dependent convolution of the Raman backscatter cross sections with the instrument function. The origins of changes in instrument response necessitate the experimental determination of the system detection efficiency. Two external light sources for calibration are assessed: zenith observation of diffuse sunlight and a xenon are lamp. The results: favor use of the diffuse-sunlight measurement but highlight the need for simultaneous sunphotometer measurements to constrain modeled aerosol optical properties. Quantum mechanical models of the Raman cross sections are described, and errors in determining the cross sections and their convolution with the instrument function are discussed in detail. The calibration coefficients deduced by using the independent method are compared with coefficients deduced from Vaisala H-Humicap radiosonde measurements. These results agree to within current calibration errors (15%, unconstrained aerosol parameters), and a change in calibration coefficient following instrument modification is reproduced satisfactorily. Results from modeling and intercomparison studies are extended to estimate the calibration accuracy and the precision of the diffuse-sunlight method with constrained modeled aerosol parameters. Changes in the calibration coefficient in the short and the long terms should be resolved to 4(6)% and 6(9)%, respectively, which is comparable or better than the precision of existing dependent methods of calibration. The reduction of the absolute calibration error remains an outstanding issue for (C) 1999 Optical Society of America OCIS codes: 010.3640, 280.3640,290.5860.
引用
收藏
页码:5816 / 5837
页数:22
相关论文
共 50 条
  • [1] Methodology for the independent calibration of raman backscatter water-vapor lidar systems
    Sherlock, Vanessa
    Hauchecorne, Alain
    Lenoble, Jacqueline
    [J]. Applied Optics, 1999, 38 (27): : 5816 - 5837
  • [2] INFLUENCE OF ATMOSPHERIC TRANSMISSION ON ACCURACY OF LIDAR WATER-VAPOR MEASUREMENTS BY RAMAN BACKSCATTER
    ARSHINOV, YF
    DANICHKIN, SA
    [J]. IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1975, 11 (04): : 414 - 416
  • [3] INDEPENDENT MEASUREMENTS OF RAMAN LIDAR WATER VAPOR CALIBRATION FACTOR
    Calhoun, M. N.
    Venable, D. D.
    Whiteman, D. N.
    [J]. 2011 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2011, : 3380 - 3383
  • [4] INDEPENDENT CALIBRATION OF WATER VAPOR RAMAN LIDAR BY USING ADDITIONAL ELASTIC MEASUREMENTS AT WATER VAPOR RAMAN WAVELENGTH
    Wu, Decheng
    Wang, Zhien
    Liu, Dong
    Xie, Chenbo
    Wang, Yingjian
    [J]. 27TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 27), 2016, 119
  • [5] Performance modeling of an airborne Raman water-vapor lidar
    Whiteman, David N.
    Schwemmer, Geary
    Berkoff, Timothy
    Plotkin, Henry
    Ramos-Izquierdo, Luis
    Pappalardo, Gelsomina
    [J]. Applied Optics, 2001, 40 (03): : 375 - 390
  • [6] Performance modeling of an airborne Raman water-vapor lidar
    Whiteman, DN
    Schwemmer, G
    Berkoff, T
    Plotkin, H
    Ramos-Izquierdo, L
    Pappalardo, G
    [J]. APPLIED OPTICS, 2001, 40 (03) : 375 - 390
  • [7] DAYTIME RAMAN-LIDAR MEASUREMENTS OF WATER-VAPOR
    RENAUT, D
    POURNY, JC
    CAPITINI, R
    [J]. OPTICS LETTERS, 1980, 5 (06) : 233 - 235
  • [8] Raman water-vapor lidar implemented on an existing lidar system in the southern tropics
    Robert, L
    Keckhut, P
    Leveau, J
    Chane-Ming, F
    Porteneuve, J
    [J]. LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING IV, 2003, 5154 : 196 - 207
  • [9] RAMAN LIDAR PROFILING OF ATMOSPHERIC WATER-VAPOR - SIMULTANEOUS MEASUREMENTS WITH 2 COLLOCATED SYSTEMS
    GOLDSMITH, JEM
    BISSON, SE
    FERRARE, RA
    EVANS, KD
    WHITEMAN, DN
    MELFI, SH
    [J]. BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1994, 75 (06) : 975 - 982
  • [10] A COMPARISON OF WATER-VAPOR MEASUREMENTS MADE BY RAMAN LIDAR AND RADIOSONDES
    FERRARE, RA
    MELFI, SH
    WHITEMAN, DN
    EVANS, KD
    SCHMIDLIN, FJ
    STARR, DO
    [J]. JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1995, 12 (06) : 1177 - 1195