Corrosion at the Cone/Taper Interface Leads to Failure of Large-diameter Metal-on-metal Total Hip Arthroplasties

被引:123
|
作者
Meyer, Heiko [1 ]
Mueller, Tina [1 ]
Goldau, Gesine [2 ]
Chamaon, Kathrin [1 ]
Ruetschi, Marcel [3 ]
Lohmann, Christoph H. [1 ]
机构
[1] Univ Magdeburg, Dept Orthopaed, D-39108 Magdeburg, Germany
[2] Univ Appl Sci, Magdeburg, Germany
[3] Loretto Hosp, Dept Orthopaed, Freiburg, Germany
关键词
WEAR PRODUCTS; ION LEVELS; REPLACEMENT; BEARINGS; DEBRIS; BLOOD; HYPERSENSITIVITY; COMPONENTS; CHROMIUM; COBALT;
D O I
10.1007/s11999-012-2502-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Metal-on-metal (MoM) THAs have reduced wear rates compared with metal-on-polyethylene. However, elevated serum metal ion levels and pseudotumors have been reported in large MoM articulations. Questions/purposes We therefore determined (1) if corrosion occurred at the cone/taper interface leading to instability in patients with large-diameter THAs; (2) how patients presented clinically and radiographically; (3) if adverse periprosthetic tissue reactions occurred; (4) whether metal was released from the implants into the periprosthetic tissues; and (5) if head size correlated with metal release. Methods We reviewed 114 patients who had revisions of large-diameter head MoM articulations. Mean time of implantation was 46 months. To identify adverse reactions and particle load, tissues were stained by hematoxylin and eosin and CD3/CD20/CD68 antibodies. Periprosthetic tissues were analyzed for metal content and distribution in different regions. Electrochemical reactions between the stem and adapter were investigated by a minicell electrode. Results Electrochemical studies on the stem and the head adapter showed a risk for galvanic corrosion. Ninety-four percent of patients had instability at the cone/taper interface. All patients presented with early clinical symptoms; 59 patients had radiographic signs of loosening. One hundred four patients had foreign body reactions and necrosis. The largest amounts of metal released were titanium or iron. We found no correlation between head size and metal ion release. Conclusions These findings suggest that in modular cone/taper connections, friction of the MoM articulations may cause failure of the cone/taper interface leading to galvanic corrosion and loosening. It is unclear whether the design of this MoM system provides sufficient stability at the taper.
引用
收藏
页码:3101 / 3108
页数:8
相关论文
共 50 条
  • [1] Taper Failure After Large-Diameter Metal-on-Metal Total Hip Arthroplasty
    Goldstein, Zachary H.
    Estrera, Kenneth
    Levine, Brett R.
    [J]. ORTHOPEDICS, 2016, 39 (05) : E984 - E987
  • [2] Large-diameter metal-on-metal total hip arthroplasties: A page in orthopedic history?
    Singh, Gurpal
    Meyer, Heiko
    Ruetschi, Marcel
    Chamaon, Kathrin
    Feuerstein, Bernd
    Lohmann, Christoph H.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2013, 101 (11) : 3320 - 3326
  • [3] Taper junction failure in large-diameter metal-on-metal bearings
    Langton, D. J.
    Sidaginamale, R.
    Lord, J. K.
    Nargol, A. V. F.
    Joyce, T. J.
    [J]. BONE & JOINT RESEARCH, 2012, 1 (04): : 56 - 63
  • [4] Large-Diameter Metal-on-Metal Cementless Total Hip Arthroplasty in the Elderly
    Zhang, Xin
    Xu, Weidong
    Li, Jia
    Fang, Zhou
    Chen, Kangyao
    [J]. ORTHOPEDICS, 2010, 33 (12)
  • [5] Dislocation of large-diameter head metal-on-metal total hip arthroplasty and hip resurfacing arthroplasty
    Miettinen, Simo S. A.
    Makinen, Tatu J.
    Laaksonen, Inari
    Makela, Keijo
    Huhtala, Heini
    Kettunen, Jukka S.
    Remes, Ville
    [J]. HIP INTERNATIONAL, 2019, 29 (03) : 253 - 261
  • [6] Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement A CONSEQUENCE OF EXCESS WEAR
    Langton, D. J.
    Jameson, S. S.
    Joyce, T. J.
    Hallab, N. J.
    Natu, S.
    Nargol, A. V. F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01): : 38 - 46
  • [7] Metal Ion Release With Large-Diameter Metal-on-Metal Hip Arthroplasty
    Vendittoli, Pascal-Andre
    Amzica, Traian
    Roy, Alain G.
    Lusignan, Daniel
    Girard, Julien
    Lavigne, Martin
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (02): : 282 - 288
  • [8] Large-diameter Metal-on-metal Total Hip Arthroplasty: Dislocation Infrequent but Survivorship Poor
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Morris, Michael J.
    Adams, Joanne B.
    Sneller, Michael A.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) : 509 - 520
  • [9] Total Hip Arthroplasty Using Large-Diameter Metal-On-Metal Articulation in Patients With Neuromuscular Weakness
    Park, Kyung-Soon
    Seon, Jong-Keun
    Lee, Keun-Bae
    Yoon, Taek-Rim
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (04): : 797 - 801
  • [10] Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip Arthroplasty
    Hasegawa, Masahiro
    Yoshida, Kakunoshin
    Wakabayashi, Hiroki
    Sudo, Akihiro
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 990 - 996