About 20 % of cervical fractures involve the C2 vertebra. Many surgical techniques have been proposed according to the type of fracture. However, morbidity and mortality of these procedures is often high, which can be attributed to the old age and significant co-morbidities of the affected population and the complex anatomy of C2. To target the latter, several authors have applied iso-C-3D guidance for most of the common techniques. We here present our experience using a fixed protocol and iso-C-3D guidance in all cases of traumatic C2 fractures. Sixteen patients were operated upon between April 2011 and April 2012 using Iso-C-3D guidance, following a fixed routine protocol. The screw position was verified by CT-scanning. Intraoperative and clinical parameters were evaluated. Six patients received anterior lag-screw fixation of odontoid fractures. Two underwent isolated posterior lag-screw fixation of hangman's fracture. C1 and/or C3 lateral mass, and/or C2 isthmic screws were placed in eight patients. No screw had to be revised, 3 minor breachings of the cortical bone of < 2 mm were observed.The same standard protocol for draping, registration of the navigation and Iso-C-3D guided drilling could be applied for anterior and posterior procedures, leaving only two variables. This led to rapid acceptance of the technique among OR-staff and surgeons, who felt comfortable with iso-C-3D guidance after only five cases. Iso-C-3D guidance is a safe and straightforward technique for anterior and posterior screw placement in the upper cervical spine.
引用
收藏
页码:1781 / 1787
页数:7
相关论文
共 50 条
  • [1] Management of C2 fractures using Iso-C3D guidance: a single institution's experience
    Sven R. Kantelhardt
    Naureen Keric
    Alf Giese
    [J]. Acta Neurochirurgica, 2012, 154 : 1781 - 1787
  • [2] Clinical experience with the Siremobil Iso-C3D imaging system in pelvic surgery
    Stöckle, U
    König, B
    Schäffler, A
    Zschernack, T
    Haas, NP
    [J]. UNFALLCHIRURG, 2006, 109 (01): : 30 - +
  • [3] Intraoperative 3D imaging of the facial skeleton using the SIREMOBIL Iso-C3D
    Heiland, M
    Schmelzle, R
    Hebecker, A
    Schulze, D
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (02) : 130 - 132
  • [4] Results of Direct Repair of Type 2 Hangman Fracture Using Iso-C3D Navigation
    Rajasekaran, S.
    Tubaki, Vijay Ramappa
    Shetty, Ajoy Prasad
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (05): : E113 - E118
  • [5] Klinische Erfahrungen mit dem Siremobil Iso-C3D-Bildwandler in der BeckenchirurgieClinical experience with the Siremobil Iso-C3D imaging system in pelvic surgery
    U. Stöckle
    B. König
    A. Schäffler
    T. Zschernack
    N. P. Haas
    [J]. Der Unfallchirurg, 2006, 109 (1): : 30 - 40
  • [6] The clinical use of the ISO-C3D imaging system in calcaneus fracture surgery
    Rübberdt, A
    Feil, R
    Stengel, D
    Spranger, N
    Mutze, S
    Wich, M
    Ekkernkamp, A
    [J]. UNFALLCHIRURG, 2006, 109 (02): : 112 - 118
  • [7] Die klinische Wertigkeit des ISO-C3D bei der Osteosynthese des FersenbeinsThe clinical use of the ISO-C3D imaging system in calcaneus fracture surgery
    A. Rübberdt
    R. Feil
    D. Stengel
    N. Spranger
    S. Mutze
    M. Wich
    A. Ekkernkamp
    [J]. Der Unfallchirurg, 2006, 109 (2): : 112 - 118
  • [8] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D)
    Heiland, M
    Schulze, D
    Adam, G
    Schmelzle, R
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) : 21 - 25
  • [9] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D)
    Schulze, D
    Heiland, M
    Adam, G
    Schmelzle, R
    Rother, U
    [J]. RADIOLOGY, 2002, 225 : 565 - 565
  • [10] The role of Iso-C3D in crush injuries to the distal lower syndesmosis: a technical report
    Khoury, Amal
    Atesok, Kivanc
    Liebergall, Meir
    Mosheiff, Rami
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (02): : 167 - 170