The feasibility of a piecewise-linear dynamic bowtie filter

被引:63
|
作者
Hsieh, Scott S. [1 ,2 ]
Pelc, Norbert J. [1 ,2 ,3 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
dynamic bowtie; fluence field modulation; dynamic range reduction; photon counting detector; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; NOISE; CT;
D O I
10.1118/1.4789630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The prepatient attenuator (or "bowtie filter") in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4789630]
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A prototype piecewise-linear dynamic attenuator
    Hsieh, Scott S.
    Peng, Mark V.
    May, Christopher A.
    Shunhavanich, Picha
    Fleischmann, Dominik
    Pelc, Norbert J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 4974 - 4988
  • [2] Implementation of a Piecewise-linear Dynamic Attenuator
    Shunhavanich, Picha
    Bennett, N. Robert
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [3] Implementation of a piecewise-linear dynamic attenuator
    Shunhavanich, Picha
    Bennett, Nathaniel Robert
    Hsieh, Scott S.
    Pelc, Norbert J.
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (02)
  • [4] On the dynamic analysis of piecewise-linear networks
    Heemels, WPMH
    Çamlibel, MK
    Schumacher, JM
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2002, 49 (03) : 315 - 327
  • [5] A TREE-STRUCTURED PIECEWISE-LINEAR ADAPTIVE FILTER
    GELFAND, SB
    RAVISHANKAR, CS
    IEEE TRANSACTIONS ON INFORMATION THEORY, 1993, 39 (06) : 1907 - 1922
  • [6] A Piecewise-Linear Model of Intracranial Pressure Dynamic
    Evans, D.
    Drapaca, C.
    Cusumano, J. P.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 595 - 600
  • [7] Piecewise-linear soliton equations and piecewise-linear integrable maps
    Quispel, GRW
    Capel, HW
    Scully, J
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 2001, 34 (11): : 2491 - 2503
  • [8] PIECEWISE-LINEAR BASIS FUNCTIONS AND PIECEWISE-LINEAR SIGNAL EXPANSIONS
    PAUL, CR
    KOCH, RW
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1974, AS22 (04): : 263 - 268
  • [9] ON AN OPTIMIZATION METHOD FOR A LINEAR DYNAMIC SYSTEM WITH A PIECEWISE-LINEAR ENTRY
    SYUEDUN, G
    KIRILLOVA, FM
    DIFFERENTIAL EQUATIONS, 1992, 28 (11) : 1531 - 1539
  • [10] Dose reduction using a dynamic, piecewise-linear attenuator
    Hsieh, Scott S.
    Fleischmann, Dominik
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2014, 41 (02)