Measuring the effects of sevoflurane on electroencephalogram using sample entropy

被引:40
|
作者
Shalbaf, R. [1 ]
Behnam, H. [1 ]
Sleigh, J. [2 ]
Voss, L. [2 ]
机构
[1] Iran Univ Sci & Technol, Sch Elect Engn, Tehran 1684613114, Iran
[2] Waikato Hosp, Dept Anesthesia, Hamilton, New Zealand
关键词
EEG; DEPTH; COMPLEXITY; ANESTHESIA; PROPOFOL;
D O I
10.1111/j.1399-6576.2012.02676.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Monitoring the effect of anesthetic drugs on the neural system is a major ongoing challenge for anesthetists. During the past few years, several electroencephalogram (EEG)-based methods such as the response entropy (RE) as implemented in the Datex-Ohmeda M-Entropy Module have been proposed. In this paper, sample entropy is used to quantify the predictability of EEG series, which could provide an index to show the effect of sevoflurane anesthesia. The doseresponse relation of sample entropy is compared with that of RE. Methods EEG data from 21 subjects is collected during the induction of general anesthesia with sevoflurane. The sample entropy is applied to the EEG recording. Pharmacokinetic-pharmacodynamic modeling and prediction probability statistic are used to evaluate the efficiency of sample entropy in comparison with RE. Results Both methods track the gross changes in EEG, especially the occurrence of burst-suppression pattern at high doses of anesthetics. However, our method produces faster reaction to transients in EEG during the induction of anesthesia as indicated from the pharmacokinetic and pharmacodynamic modeled parameters and analysis around the point of loss of consciousness. Also, sample entropy correlated more closely with effect-site sevoflurane concentration than the RE. In addition, our proposed method exhibits greater resistance to noise in the EEG signals. Conclusion The results demonstrate that sample entropy can estimate the sevoflurane drug effect on the EEG more effectively than the commercial RE index with a stronger noise resistance.
引用
收藏
页码:880 / 889
页数:10
相关论文
共 50 条
  • [1] Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia
    Hans, P
    Dewandre, PY
    Brichant, JF
    Bonhomme, V
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 336 - 340
  • [2] Pharmacokinetic-pharmacodynamic modeling the hypnotic effect of sevoflurane using the spectral entropy of the electroencephalogram
    McKay, IDH
    Voss, LJ
    Sleigh, JW
    Barnard, JP
    Johannsen, EK
    ANESTHESIA AND ANALGESIA, 2006, 102 (01): : 91 - 97
  • [3] Neurodevelopment in newborns: a sample entropy analysis of electroencephalogram
    Zhang, Dandan
    Ding, Haiyan
    Liu, Yunfeng
    Zhou, Congle
    Ding, Haishu
    Ye, Datian
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (05) : 491 - 504
  • [4] Effects of isoflurane, sevoflurane and methoxyflurane on the electroencephalogram of the chicken
    McIlhone, Amanda E.
    Beausoleil, Ngaio J.
    Johnson, Craig B.
    Mellor, David J.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2014, 41 (06) : 613 - 620
  • [5] Using permutation entropy to measure the electroencephalographic effects of sevoflurane
    Li, Xiaoli
    Cui, Suyuan
    Voss, Logan J.
    ANESTHESIOLOGY, 2008, 109 (03) : 448 - 456
  • [6] Effects of Sevoflurane and Propofol on Frontal Electroencephalogram Power and Coherence
    Akeju, Oluwaseun
    Westover, M. Brandon
    Pavone, Kara J.
    Sampson, Aaron L.
    Hartnack, Katharine E.
    Brown, Emery N.
    Purdon, Patrick L.
    ANESTHESIOLOGY, 2014, 121 (05) : 990 - 998
  • [7] Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane
    Aho, A. J.
    Kamata, K.
    Jantti, V.
    Kulkas, A.
    Hagihira, S.
    Huhtala, H.
    Yli-Hankala, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (02) : 258 - 266
  • [8] Automatic detection of seizure termination during electroconvulsive therapy using sample entropy of the electroencephalogram
    Yoo, Cheol Seung
    Jung, Dong Chung
    Ahn, Yong Min
    Kim, Yong Sik
    Kim, Su-Gyeong
    Yoon, Hyeri
    Lim, Young Jin
    Yi, Sang Hoon
    PSYCHIATRY RESEARCH, 2012, 195 (1-2) : 76 - 82
  • [9] Automatic detection of seizure termination during electroconvulsive therapy using sample entropy of electroencephalogram
    Jung, D. C.
    Yoo, C. S.
    Yi, S. H.
    Ahn, Y. M.
    Kim, S. -G.
    Yoon, H.
    Kim, Y. S.
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2010, 13 : 222 - 223
  • [10] Measuring Body Temperature Time Series Regularity Using Approximate Entropy and Sample Entropy
    Cuesta-Frau, D.
    Miro-Martinez, P.
    Oltra-Crespo, S.
    Varela-Entrecanales, M.
    Aboy, M.
    Novak, D.
    Austin, D.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3461 - 3464